{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7288-1SR60-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7288-1SR60-0AA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7288-1SR60-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7288-1SR60-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-200 SMART CPU SR60, 6ES7288-1SR60-0AA0, 30 kbyte program memory, 144 byte I/O, 6 high-speed counters, PID control, PROFINET, RS485, DIN-rail mount.","salesMarkdown":"The Siemens 6ES7288-1SR60-0AA0 is the SR60 CPU in the S7-200 SMART line. It packs 30 kbyte of program memory (DDR), 144 bytes each of input and output image (256 bits digital plus 56 words analog per side), and runs LAD, FBD, and STL. The onboard PID controller handles up to 8 loops with continuous or binary outputs and auto/manual bump-less transfer — enough for a small packaging machine or a pump skid without a separate loop controller. Six high-speed counters are built in: four single-phase at 200 kHz and two at 30 kHz, or four A/B-phase at 100 kHz and two at 20 kHz, all parameterizable. That covers encoder feedback for a servo axis or a conveyor position loop without an add-on module. PROFINET IO is native with autonegotiation and autocrossing, minimum update time 4 ms. PROFIBUS DP is available via a CM DP module — the CPU can act as client or server. An RS485 port runs up to 187.5 kbps, shielded cable max 500 m. Two-wire or four-wire fieldbus drops are covered without extra comm cards. Mounts on standard DIN rail. Dimensions 175 mm wide × 100 mm high × 81 mm deep. The hardware clock is maintenance-free with a 7-day backup — no battery to swap, but the RTC holds for a week without power. Power supply accepts 120 V AC or 230 V AC, transformer-isolated at 1500 V AC. That isolation keeps line noise off the backplane — useful when the same cabinet has drives or contactors. ## I/O and forcing Digital input signal thresholds: 5 V DC at 1 mA for a '0', 15 V DC at 2.5 mA for a '1'. Outputs are 144 bytes total. Forcing is supported — you can override an input or output in the program state for commissioning without rewiring.","metaTitle":"Siemens 6ES7288-1SR60-0AA0 S7-200 SMART CPU, 30 kbyte, PID,","metaDescription":"Siemens 6ES7288-1SR60-0AA0 S7-200 SMART CPU SR60. 30 kbyte program memory, 8 PID loops, 6 HSCs, PROFINET, RS485. DIN-rail mount, -40 to 70 °C. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"FBD":"Yes","LAD":"Yes","RAM":"Yes","STL":"Yes","Max.":"70 °C","Min.":"-40 °C","Type":"Hardware clock, no battery backup","Depth":"81 mm","Flash":"Yes","Width":"175 mm","title":"6ES7288-1SR60-0AA0","Height":"100 mm","Inputs":"144 byte; 256 bit of digital inputs & 56 words of analog inputs","RS 485":"Yes","TCP/IP":"Yes","CE mark":"Yes","Forcing":"Yes","Outputs":"144 byte; 256 bit of digital outputs & 56 words of analog outputs","Present":"Yes; Maintenance free, RTC requires 7 days.","120 V AC":"Yes","230 V AC":"Yes","Isolated":"Yes; Transformer isolated, 1,500V AC","PROFIBUS":"Yes; Via CM DP module","As Client":"Yes","As Server":"Yes","Supported":"Yes","Backup time":"7 d","Memory size":"30 kbyte; Program memory","description":"*** spare part *** SIMATIC S7-200 SMART, CPU SR60, CPU, AC/DC/relay, onboard I/O: 36 DI 24 V DC; 24 DO relay 2 A; power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 50 KB","Autocrossing":"Yes","Inputs, max.":"128 byte; Per device","Outputs, max.":"128 byte; Per device","Rail mounting":"Yes; Standard - DIN rail","Updating time":"4 ms; The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Interface type":"RS 485 (max. 187.5 kbps)","PID controller":"Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops","Shielded, Max.":"500 m","Type of memory":"DDR","Autonegotiation":"Yes","Parameterizable":"Yes; 6 Single phase: 4 HSCs at 200 kHz; 2 HSCs at 30 kHz 4 A/B phase: 2 HSCs at 100 kHz; 2 HSCs at 20 kHz","Weight, approx.":"611.5 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms; max.","\"1\" To \"0\", Max.":"10 ms; max.","Power loss, max.":"25 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","S7 communication":"Yes","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","Micro Memory Card":"Yes; microSDHC Card (optional)","Source/sink input":"Yes","Number of counters":"6","On Lamp Load, Max.":"30 W; 30 W with DC, 200 W with AC","PROFINET IO Device":"Yes; I-Device since V2.5","up to 40 °C, max.":"36","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.2 ms","Programming package":"STEP 7 Micro/WIN SMART","Current output, max.":"300 mA; 24 V DC Sensor Power","For Signal \"1\", Typ.":"4 mA","Inrush current, max.":"16.3 A; at 264 V","Type of input voltage":"DC","PROFINET IO Controller":"Yes; Since V2.4","Deviation per day, max.":"120 s; within 120s/month at 25 °C","IP degree of protection":"IP20","Number of pulse outputs":"3","Number of relay outputs":"24","Storage/transport, max.":"1 080 hPa","Storage/transport, min.":"660 hPa","Transmission rate, max.":"100 Mbit/s","For Bit Operations, Typ.":"150 ns; / instruction","Number of digital inputs":"36; Integrated","Current consumption, max.":"370 mA; At 120 V AC","For Word Operations, Typ.":"1.2 µs; / instruction","Number of digital outputs":"24; Relays","With Resistive Load, Max.":"2 A","Hardware clock (real-time)":"Yes","Installation altitude, max.":"2 000 m","Installation altitude, min.":"-1 000 m","Number of RS 485 interfaces":"1","Vertical Installation, Max.":"45 °C","Vertical Installation, Min.":"0 °C","Horizontal Installation, Max.":"55 °C","Horizontal Installation, Min.":"0 °C","Test voltage at air discharge":"8 kV","Memory available for user data":"20 kbyte","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","for backplane bus (5 V DC), max.":"1.4 A; max. 5 V DC for EM bus","Current consumption (rated value)":"220 mA; at 240 V AC","Supports protocol for PROFINET IO":"Yes; RT Controller (since FW V2.4) & I-Device (since FW V2.5)","Test voltage at contact discharge":"4 kV","For Floating Point Arithmetic, Typ.":"3.6 µs; / instruction","permissible range, lower limit (AC)":"85 V","permissible range, upper limit (AC)":"264 V","Number of connectable IO Devices, max.":"8","Automatic Detection Of Transmission Rate":"Yes; 10/100 Mbit/s","Number of industrial Ethernet interfaces":"1","Limit class A, for use in industrial areas":"Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas.","Operation at 25 °C without condensation, max.":"95 %","Of The Pulse Outputs, With Resistive Load, Max.":"1 Hz","Interference emission via line/AC current cables":"EN 61000-6-4, interference emission: Intended for use in industrial areas.","Of Which Inputs Usable For Technological Functions":"4; HSC (High Speed Counting)","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$492.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b931924b4417309cfd84c516d590e95f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=157718&mlfb=6ES7288-1SR60-0AA0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7288-1SR60-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7288-1SR60-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}