{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7313-5BE00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7313-5BE00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7313-5BE00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7313-5BE00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 CPU module, 6ES7313-5BE00-0AB0, 248 inputs / 124 outputs, 32 kB memory, MPI, FBD, LAD, SCL, STL, GRAPH, HiGraph.","salesMarkdown":"## CPU specification note Siemens 6ES7313-5BE00-0AB0 supports programming in FBD, LAD, SCL, STL, GRAPH, and HiGraph. Integrated 32 kbyte memory holds both program and data; an additional 16 kbyte expansion is available for function module specific uses. Digital I/O address range covers 248 inputs and 124 outputs, with analog inputs accepting 0 to 10 V, 0 to 20 mA, Pt100, and resistance up to 600 ohms. Communication is via MPI plus optional CP modules: up to 1 via CP, 2 for LAN, and 4 for point-to-point links. The CPU is not galvanically isolated from the backplane — reference potential is shared, so panel grounding must account for that.","metaTitle":"Siemens 6ES7313-5BE00-0AB0 S7-300 CPU, 248 I/O, MPI, FBD/LAD","metaDescription":"Siemens 6ES7313-5BE00-0AB0 S7-300 CPU module. 32 kB integrated memory, 248 inputs / 124 outputs, MPI, programming in FBD, LAD, SCL, STL, GRAPH, HiGraph. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","FBD":"Yes","LAD":"Yes","MPI":"Yes","SCL":"Yes","STL":"Yes","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"120 mm","Height":"125 mm","Inputs":"248","Number":"1","Pt 100":"Yes","STEP 7":"Yes; V5.1 SP2","via CP":"1","CP, LAN":"2","CP, PtP":"4","Current":"Yes","Outputs":"124","Overall":"8","Present":"Yes","Voltage":"Yes","Isolated":"No","0 to 10 V":"Yes","As Client":"No","As Server":"Yes","HiGraph®":"Yes","Supported":"Yes","0 to +10 V":"Yes","0 to 20 mA":"Yes","Adjustable":"Yes","Expandable":"No","Integrated":"32 kbyte; For program and data","Resistance":"Yes","Size, max.":"16 kbyte","Lower Limit":"10 ms","Upper Limit":"9 990 s","Number, max.":"256 byte","0 To 600 Ohms":"Yes","2-Wire Sensor":"Yes","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Nesting levels":"8","PID controller":"Yes","Shielded, Max.":"1 000 m","Parameterizable":"Yes; 0.1 / 0.3 / 3 / 15 ms","Weight, approx.":"660 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","-20 mA to +20 mA":"Yes","Power loss, typ.":"14 W","Rated value (DC)":"24 V","S7 communication":"Yes","Unshielded, Max.":"600 m","PROFIBUS DP slave":"No","expandable FEPROM":"Yes; with Micro Memory Card (MMC)","Cable length, max.":"50 m; without repeater","Number of counters":"3","PROFIBUS DP master":"No","Per Priority Class":"8","up to 40 °C, max.":"8 A","up to 60 °C, max.":"4 A","At \"0\" To \"1\", Max.":"16 µs","PG/OP communication":"Yes","For Signal \"1\", Min.":"L+ (-0.8 V)","For Signal \"1\", Typ.":"8 mA","Inrush current, typ.":"11 A","Frequency measurement":"Yes","Number of connections":"8","Retentivity available":"Yes; MB 0 to MB 255","Modules per rack, max.":"31","Resistance thermometer":"Yes","Limit frequency (pulse)":"2.5 kHz","Number of analog inputs":"4","Number of pulse outputs":"3","Transmission rate, max.":"187.5 kbit/s","User data per job, max.":"64 kbyte","expandable FEPROM, max.":"4 Mbyte","For Bit Operations, Max.":"0.2 µs","For Bit Operations, Typ.":"0.1 µs","Number of analog outputs":"2","Number of digital inputs":"24","Number of time alarm OBs":"1","Short-circuit protection":"Yes; Clocked electronically","Size of GD packets, max.":"22 byte","For Word Operations, Typ.":"0.5 µs","Global data communication":"Yes","Number of delay alarm OBs":"1","Number of digital outputs":"16","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","Hardware clock (real-time)":"Yes","Number of process alarm OBs":"1","S7 communication, as client":"No","S7 communication, as server":"Yes","usable for OP communication":"7","usable for PG communication":"7","Retentive And Synchronizable":"Yes","Conversion time (per channel)":"1 ms","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Number of cyclic interrupt OBs":"1","For voltage/current measurement":"4","Number of expansion units, max.":"3","For Fixed Point Arithmetic, Typ.":"1 µs","Counting frequency (counter) max.":"30 kHz","Current consumption (rated value)":"700 mA","Integration time, parameterizable":"Yes; 2,5 / 16,6 / 20 ms","usable for S7 basic communication":"4","Between The Channels, In Groups Of":"8","Potential separation analog inputs":"Yes; common for analog I/O","For Floating Point Arithmetic, Typ.":"15 µs","For Signal \"1\" Minimum Load Current":"5 mA","Potential separation analog outputs":"Yes","Potential separation digital inputs":"Yes","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"4","Number of GD packets, receiver, max.":"4","For Signal \"0\" Residual Current, Max.":"0.5 mA","adjustable for OP communication, max.":"7","adjustable for PG communication, max.":"7","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.7 %","Number of GD packets, transmitter, max.":"4","Voltage, relative to input range, (+/-)":"0.7 %","Current, relative to output range, (+/-)":"0.7 %","Voltage, relative to output range, (+/-)":"0.7 %","Resistance, relative to input range, (+/-)":"3 %","Limitation of inductive shutdown voltage to":"L+ (-48 V)","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"4","For resistance/resistance thermometer measurement":"1","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Number of login stations for message functions, max.":"5","Resolution with overrange (bit including sign), max.":"12 bit","Resistance thermometer, relative to input range, (+/-)":"3 %","for signal \"1\" permissible range for 0 to 60 °C, max.":"500 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$422.22","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=158892&mlfb=6ES7313-5BE00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7313-5BE00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What programming languages does this CPU support?","answer":"It supports FBD, LAD, SCL, STL, GRAPH, and HiGraph."},{"question":"Is the CPU isolated from the backplane?","answer":"No, it is not isolated. The backplane and CPU share a common reference potential."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7313-5BE00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7313-5BE00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}