{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7313-5BF03-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7313-5BF03-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7313-5BF03-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7313-5BF03-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 CPU 313C order 6ES7313-5BF03-0AB0, 8 integrated function modules (FM), integrated I/O, 120 mm width, supports MPI/RS-485, multiple programming languages.","salesMarkdown":"## CPU with Built-In Function Modules The Siemens 6ES7313-5BF03-0AB0 is a CPU 313C with eight integrated function modules (FM 8) for counting, frequency measurement, and PWM generation. It also includes integrated digital I/O and supports MPI and RS-485 communication. Programmed in LAD, FBD, SCL, STL, GRAPH, and HiGraph under STEP 7 V5.3 SP2 or later. This version requirement means the CPU is not natively supported in TIA Portal without importing the project via the STEP 7 converter. ## Mechanical and Panel Fit The module occupies 120 mm width on the S7-300 DIN rail, equivalent to three standard 40 mm slots. Height is 125 mm, depth 130 mm. Verify slot availability in the rack (standard or active bus rail) before ordering. Not expandable — the built-in I/O and function modules are fixed. No additional signal modules can be added via the backplane. Plan all required I/O capacity and function blocks into the CPU selection upfront.","metaTitle":"Siemens 6ES7313-5BF03-0AB0 S7-300 CPU 313C, 8 FM, Integrated","metaDescription":"CPU 313C with 8 function modules, integrated digital I/O, supports LAD/FBD/SCL/STL/GRAPH/HiGraph, MPI/RS485, STEP 7 V5.3 SP2. Non-expandable. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","FBD":"Yes","I2t":"0.7 A²·s","LAD":"Yes","MPI":"Yes","SCL":"Yes","STL":"Yes","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"120 mm","Height":"125 mm","Inputs":"253","Number":"1","Preset":"No retentivity","Pt 100":"Yes","RS 485":"Yes","STEP 7":"Yes; V5.3 SP2 with HW update","via CP":"4","CP, LAN":"6","CP, PtP":"8","Current":"Yes","Forcing":"Yes","Outputs":"250","Overall":"8","Present":"Yes","Routing":"No","Isolated":"No","0 to 10 V":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","HiGraph®":"Yes","PROFIsafe":"No","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","0 to +10 V":"Yes","0 to 20 mA":"Yes","Adjustable":"Yes","Expandable":"No","Resistance":"Yes","Size, max.":"256 byte","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"48 Ω","Racks, max.":"4","Rated value":"3 ms","Single step":"Yes","Upper Limit":"4 kΩ","For Uprating":"No","Number, max.":"1 024; Number range: 0 to 2047","Status block":"Yes","0 To 600 Ohms":"Yes","2-Wire Sensor":"Yes","4 mA to 20 mA":"Yes","Analog inputs":"752 to 761","Current, max.":"50 mA; Permanent","Plug-in (MMC)":"Yes","in AS, master":"Yes","to MPI, slave":"Yes","-10 V to +10 V":"Yes","Analog outputs":"752 to 755","Digital inputs":"124.0 to 126.7","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","PID controller":"Yes","Shielded, Max.":"200 m","to MPI, master":"Yes","Digital outputs":"124.0 to 125.7","Parameterizable":"Yes; by software","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"660 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","-20 mA to +20 mA":"Yes","Firmware version":"V2.6","Of Which Central":"250","Power loss, typ.":"14 W","Rated value (DC)":"24 V","S7 communication":"Yes","Unshielded, Max.":"600 m","PROFIBUS DP slave":"No","Cable length, max.":"50 m; without repeater","For Inductive Load":"0.5 ms","For Resistive Load":"0.6 ms","Forcing, variables":"Inputs, outputs","Number of counters":"3; 3 channels (see \"Technological Functions\" manual)","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"No","Per Priority Class":"8","Retentivity preset":"Yes","Usable For Routing":"No","up to 40 °C, max.":"2 A","up to 60 °C, max.":"2 A","At \"0\" To \"1\", Max.":"16 µs","For Capacitive Load":"1 ms","Number/Number range":"0","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V5.3 SP2 or higher with HW update","Between The Channels":"No","For Signal \"1\", Min.":"L+ (-0.8 V)","For Signal \"1\", Typ.":"9 mA","HW functional status":"01","Inrush current, typ.":"11 A","Frequency measurement":"Yes","Isolation tested with":"600 V DC","Measurement principle":"Actual value encryption (successive approximation)","Number of breakpoints":"2","Number of connections":"8","Number of startup OBs":"1; OB 100","Retentivity available":"Yes; MB 0 to MB 255","Controlled Positioning":"No","Modules per rack, max.":"8; In rack 3 max. 7","Resistance thermometer":"Yes; Pt 100 / 10 MΩ","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"Yes","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","For Voltage Measurement":"Yes","Limit frequency (pulse)":"2.5 kHz","Number of entries, max.":"100","Number of pulse outputs":"3; 3 channels pulse width modulation up to max. 2.5 kHz (see \"Technological Functions\" manual)","Status/control variable":"Yes","Transmission rate, max.":"187.5 kbit/s","User data per job, max.":"180 byte; With PUT/GET","Counting frequency, max.":"30 kHz","For Bit Operations, Max.":"0.2 µs","For Bit Operations, Typ.":"0.1 µs","Number of GD loops, max.":"4","Number of analog outputs":"2","Number of blocks (total)":"1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"24","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Per Priority Class, Max.":"510 byte","Response threshold, typ.":"1 A","Short-circuit protection":"Yes; Clocked electronically","Size of GD packets, max.":"22 byte","integrated channels (AI)":"4+1","integrated channels (AO)":"2","integrated channels (DI)":"24","integrated channels (DO)":"16","For Word Operations, Typ.":"0.2 µs","Global data communication":"Yes","Input resistance (Pt 100)":"10 MΩ","Number of delay alarm OBs":"1; OB 20","Number of digital outputs":"16","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","For Resistance Thermometer":"Pt 100","For Signal \"1\" Rated Value":"500 mA","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"4","Number of frequency meters":"3; 3 channels up to max. 30 kHz (see \"Technological Functions\" manual)","With Current Outputs, Max.":"300 Ω","With Voltage Outputs, Min.":"1 kΩ","from load voltage L+, max.":"100 mA","Controlling a digital input":"Yes","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"1; MPI","Number of process alarm OBs":"1; OB 40","Of Which High-Speed Outputs":"4","Process diagnostic messages":"Yes","Reverse polarity protection":"Yes","S7 communication, as client":"No","S7 communication, as server":"Yes","usable for OP communication":"7","usable for PG communication":"7","Input resistance (0 to 10 V)":"100 kΩ","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Conversion time (per channel)":"1 ms","Input resistance (0 to 20 mA)":"100 Ω","Number of PROFINET interfaces":"0","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Common mode interference, min.":"40 dB","Number of cyclic interrupt OBs":"1; OB 35","For Redundant Control Of A Load":"Yes","For voltage/current measurement":"4","Number of expansion units, max.":"3","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","Electrical input frequency, max.":"400 Hz","For Fixed Point Arithmetic, Typ.":"2 µs","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"100 Ω","Number of asynchronous error OBs":"4; OB 80, 82, 85, 87","Of Which Control Variables, Max.":"14","Current consumption (rated value)":"700 mA","Integration time, parameterizable":"Yes; 2,5 / 16,6 / 20 ms","Time constant of the input filter":"0.38 ms","usable for S7 basic communication":"4","Between The Channels, In Groups Of":"8","Crosstalk between the inputs, min.":"60 dB","Potential separation analog inputs":"Yes; common for analog I/O","Crosstalk between the outputs, min.":"60 dB","For Floating Point Arithmetic, Typ.":"3 µs","For Signal \"1\" Minimum Load Current":"5 mA","Input resistance (-20 mA to +20 mA)":"100 Ω","Potential separation analog outputs":"Yes; common for analog I/O","Potential separation digital inputs":"Yes","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Number of GD packets, receiver, max.":"4","Potential separation digital outputs":"Yes","Voltages at the outputs towards MANA":"16 V; Permanent","Current output, no-load voltage, max.":"17 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Output current of the interface, max.":"200 mA","adjustable for OP communication, max.":"7","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"7","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Signal \"1\" Permissible Range, Max.":"0.6 A","For Signal \"1\" Permissible Range, Min.":"5 mA","For Voltage Output Two-Wire Connection":"Yes; Without compensation of the line resistances","Status indicator digital input (green)":"Yes","Current, relative to input range, (+/-)":"0.7 %; Linearity error ±0.06 %","For Voltage Output Four-Wire Connection":"No","Number of GD packets, transmitter, max.":"4","Status indicator digital output (green)":"Yes","Voltage, relative to input range, (+/-)":"0.7 %; Linearity error ±0.06 %","Current, relative to output range, (+/-)":"0.7 %","Number of industrial Ethernet interfaces":"0","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.7 %","from load voltage L+ (without load), max.":"70 mA","Resistance, relative to input range, (+/-)":"3 %; Linearity error ±0.2 %","With Current Outputs, Inductive Load, Max.":"0.1 mH","simultaneously active Alarm-S blocks, max.":"20","Limitation of inductive shutdown voltage to":"L+ (-48 V)","User program protection/password protection":"Yes","Voltage output, short-circuit current, max.":"55 mA","With Voltage Outputs, Capacitive Load, Max.":"0.1 µF","adjustable for S7 basic communication, max.":"4","adjustable for S7 basic communication, min.":"0","For Current Measurement As 2-Wire Transducer":"Yes; with external supply","For Current Measurement As 4-Wire Transducer":"Yes","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"64 byte","Of The Pulse Outputs, With Resistive Load, Max.":"2.5 kHz","Current consumption (in no-load operation), typ.":"150 mA","Integrated Function Blocks (Closed-Loop Control)":"Yes; PID controller (see \"Technological Functions\" manual)","For resistance/resistance thermometer measurement":"1","Linearity error (relative to output range), (+/-)":"0.15 %","Of Which Inputs Usable For Technological Functions":"12","Temperature error (relative to input range), (+/-)":"0.006 %/K","For Resistance Measurement With Two-Wire Connection":"Yes; Without compensation of the line resistances","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Temperature error (relative to output range), (+/-)":"0.01 %/K","For Resistance Measurement With Four-Wire Connection":"No","Number of login stations for message functions, max.":"8; Depending on the configured connections for PG/OP and S7 basic communication","Resolution with overrange (bit including sign), max.":"12 bit","Data management on MMC (after last programming), min.":"10 a","For Resistance Measurement With Three-Wire Connection":"No","No-load voltage for resistance-type transmitter, typ.":"2.5 V","Technical unit for temperature measurement adjustable":"Yes; Degrees Celsius / degrees Fahrenheit / Kelvin","Resistance thermometer, relative to input range, (+/-)":"3 %","Retentive data area (incl. timers, counters, flags), max.":"64 kbyte","Basic execution time of the module (all channels released)":"1 ms","External Protection For Power Supply Lines (Recommendation)":"Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A","Constant measurement current for resistance-type transmitter, typ.":"1.8 to 3.3 mA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA; Permanent","Permissible Input Current For Voltage Input (Destruction Limit), Max.":"0.5 mA; Permanent","Permissible Input Voltage For Current Input (Destruction Limit), Max.":"5 V; Permanent","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V; Permanent","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.1 %","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.06 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.06 %","Series mode interference (peak value of interference < rated value of input range), min.":"30 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$177.77","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=356585&mlfb=6ES7313-5BF03-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7313-5BF03-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What integrated function modules does the 6ES7313-5BF03-0AB0 include?","answer":"It includes eight function modules (FM 8) for high-speed counting, frequency measurement, and PWM output, programmable via the same engineering software."},{"question":"What communication ports does the 6ES7313-5BF03-0AB0 have?","answer":"It has one MPI/RS-485 port. Additional communication (PROFIBUS, PROFINET, PtP) requires a separate CP module in the rack, up to 4 via CP, 6 via LAN CP, 8 via PtP CP."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7313-5BF03-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7313-5BF03-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}