{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7313-6CF03-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7313-6CF03-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7313-6CF03-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7313-6CF03-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-300 CPU 313C-2 DP, 6ES7313-6CF03-0AB0, compact PLC with 244 byte inputs and outputs, integrated PROFIBUS DP interface, 8 function blocks, 6-week backup time.","salesMarkdown":"## CPU 313C-2 DP — what the I/O and interface ratings mean for a controls integrator The Siemens 6ES7313-6CF03-0AB0 is a CPU 313C-2 DP from the S7-300 family, built for mid-range control tasks where you need a compact CPU with a built-in PROFIBUS DP master/slave port. The 244 byte input and 244 byte process-image output areas define the maximum I/O data the CPU can exchange each cycle — enough for a few hundred digital points or a couple of analog modules before you hit the addressing ceiling. The integrated DP interface runs RS 485 and is isolated, supporting both DP master (client) and DP slave (server) roles — the client mode requires a CP and a loadable FB, while the server mode is native. Routing is supported only when the active interface is present, so plan the network topology accordingly. ## Programming languages and memory backup — what the spec table tells a commissioning engineer This CPU supports LAD, FBD, STL, SCL, GRAPH, and HiGraph. The 8 function blocks (FM 8) are available for technology functions. The backup time of 6 weeks means the CPU retains the RAM content for up to 6 weeks without external power. The maximum data size per communication job is 256 bytes — relevant when configuring data exchange with a CP or an HMI. Forcing is supported, which lets you override I/O states during commissioning without changing the program. The depth includes the front connector and the bus connector to the adjacent module, so leave clearance for the cabling channel.","metaTitle":"Siemens 6ES7313-6CF03-0AB0 CPU 313C-2 DP, 244 byte I/O","metaDescription":"Siemens 6ES7313-6CF03-0AB0 CPU 313C-2 DP PLC with 244 byte inputs/outputs, integrated DP interface, RS 485, 6-week backup. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","FBD":"Yes","I2t":"0.7 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","DPV1":"No","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"120 mm","Height":"125 mm","Inputs":"244 byte","Number":"1","Preset":"No retentivity","RS 485":"Yes","STEP 7":"Yes; V5.3 SP2 with HW update","via CP":"4","CP, LAN":"6","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"8","Present":"Yes","Routing":"Yes; Only with active interface","GSD file":"The latest GSD file is available at: http://www.siemens.com/profibus-gsd","Isolated":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","HiGraph®":"Yes","Retentive":"Yes","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"No","Expandable":"No","Integrated":"1","Size, max.":"256 byte","Backup time":"6 wk","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"48 Ω","Racks, max.":"4","Rated value":"3 ms","SYNC/FREEZE":"Yes","Single step":"Yes","Upper Limit":"4 kΩ","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"244 byte","Number, max.":"1 024; Number range: 0 to 2047","PROFINET CBA":"No","Status block":"Yes","to DP, slave":"Yes","2-Wire Sensor":"Yes","Outputs, max.":"244 byte","Plug-in (MMC)":"Yes","in AS, master":"Yes","to DP, master":"Yes; With DP slave only slave clock","to MPI, slave":"Yes","Digital inputs":"124.0 to 125.7","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","PID controller":"Yes","Shielded, Max.":"1 000 m","to MPI, master":"Yes","Digital outputs":"124.0 to 125.7","Parameterizable":"Yes; 0.1 / 0.3 / 3 / 15 ms","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"566 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","Isochronous mode":"No","Of Which Central":"248","Power loss, typ.":"10 W","Rated value (DC)":"24 V","S7 communication":"Yes","Unshielded, Max.":"600 m","PROFIBUS DP slave":"Yes","Address area, max.":"32","Cable length, max.":"50 m; without repeater","Forcing, variables":"Inputs, outputs","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"Yes","Per Priority Class":"8","Retentivity preset":"Yes","Usable For Routing":"4; max.","up to 40 °C, max.":"2 A","up to 60 °C, max.":"2 A","At \"0\" To \"1\", Max.":"16 µs","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V5.3 SP2 or higher with HW update","Between The Channels":"Yes","For Signal \"1\", Min.":"L+ (-0.8 V)","For Signal \"1\", Typ.":"9 mA","Inrush current, typ.":"11 A","Frequency measurement":"Yes","Isolation tested with":"600 V DC","Number of breakpoints":"2","Number of connections":"8","Number of startup OBs":"1; OB 100","Retentivity available":"Yes; MB 0 to MB 255","Controlled Positioning":"No","Modules per rack, max.":"8; In rack 3 max. 7","PROFINET IO Controller":"No","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","Limit frequency (pulse)":"2.5 kHz","Number of entries, max.":"100","Number of pulse outputs":"3; 3 channels pulse width modulation up to max. 2.5 kHz (see \"Technological Functions\" manual)","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"180 kbyte; With PUT/GET","For Bit Operations, Max.":"0.2 µs","For Bit Operations, Typ.":"0.1 µs","Number of DPV1 alarm OBs":"3; OB 55, 56, 57","Number of GD loops, max.":"4","Number of blocks (total)":"1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"16","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Per Priority Class, Max.":"510 byte","Response threshold, typ.":"1 A","Short-circuit protection":"Yes; Clocked electronically","Size of GD packets, max.":"22 byte","integrated channels (AI)":"0","integrated channels (AO)":"0","integrated channels (DI)":"16","integrated channels (DO)":"16","For Word Operations, Typ.":"0.2 µs","Global data communication":"No","Number of DP slaves, max.":"32","Number of delay alarm OBs":"1; OB 20","Number of digital outputs":"16","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"Yes; only with passive interface","For Signal \"1\" Rated Value":"500 mA","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"4","Number of frequency meters":"3; 3 channels up to max. 30 kHz (see \"Technological Functions\" manual)","from load voltage L+, max.":"100 mA","Controlling a digital input":"Yes","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"2; MPI and PROFIBUS DP","Number of connections, max.":"8; For PG/OP communication","Number of process alarm OBs":"1; OB 40","Of Which High-Speed Outputs":"4","Process diagnostic messages":"Yes","Reverse polarity protection":"No","S7 communication, as client":"No","S7 communication, as server":"Yes","usable for OP communication":"7","usable for PG communication":"7","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Number of PROFINET interfaces":"0","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Number of cyclic interrupt OBs":"1; OB 35","For Redundant Control Of A Load":"Yes","Number of expansion units, max.":"3","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","For Fixed Point Arithmetic, Typ.":"2 µs","Number of asynchronous error OBs":"5; OB 80, 82, 85, 86, 87","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","Current consumption (rated value)":"900 mA","usable for S7 basic communication":"4","Between The Channels, In Groups Of":"8","For Floating Point Arithmetic, Typ.":"3 µs","For Signal \"1\" Minimum Load Current":"5 mA","Potential separation digital inputs":"Yes","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","Number of GD packets, receiver, max.":"4","Potential separation digital outputs":"Yes","For Signal \"0\" Residual Current, Max.":"0.5 mA","Output current of the interface, max.":"200 mA","adjustable for OP communication, max.":"7","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"7","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","For Signal \"1\" Permissible Range, Max.":"0.6 A","For Signal \"1\" Permissible Range, Min.":"5 mA","Status indicator digital input (green)":"Yes","Number of GD packets, transmitter, max.":"4","Status indicator digital output (green)":"Yes","Number of industrial Ethernet interfaces":"0","from load voltage L+ (without load), max.":"70 mA","simultaneously active Alarm-S blocks, max.":"20","Limitation of inductive shutdown voltage to":"L+ (-48 V)","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"4","adjustable for S7 basic communication, min.":"0","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"64 byte","Of The Pulse Outputs, With Resistive Load, Max.":"2.5 kHz","Current consumption (in no-load operation), typ.":"100 mA","Integrated Function Blocks (Closed-Loop Control)":"PID controller (see \"Technological Functions\" manual)","Of Which Inputs Usable For Technological Functions":"12","Direct data exchange (slave-to-slave communication)":"Yes","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Number of login stations for message functions, max.":"8","Data management on MMC (after last programming), min.":"10 y","External Protection For Power Supply Lines (Recommendation)":"Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$495.30 – $1,169.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=55268&mlfb=6ES7313-6CF03-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7313-6CF03-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What memory card is required for 6ES7313-6CF03-0AB0?","answer":"The evidence does not specify a required memory card type or size. The CPU has a backup time of 6 weeks for RAM retention, and the maximum data size per communication job is 256 bytes. For specific memory card compatibility, the original S7-300 micro memory card (MMC) is typically used, but confirm the exact part against the CPU's firmware version."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7313-6CF03-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7313-6CF03-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}