{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7315-6TG10-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7315-6TG10-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7315-6TG10-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7315-6TG10-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 Technology CPU 315T-2 DP, 6ES7315-6TG10-0AB0, with 2 integrated PROFIBUS DP interfaces, 244 byte inputs and outputs, FM 8, CFC, FBD, LAD, SCL, STL, GRAPH, HiGraph, 130 mm depth, 160 mm width, 125 mm height.","salesMarkdown":"## CPU 315T-2 DP: Technology Controller for Motion Sequences The Siemens 6ES7315-6TG10-0AB0 is a Technology CPU from the S7-300 family, purpose-built for controlling motion sequences like cam switches, synchronised axes, and high-speed positioning — not a general-purpose logic controller. It carries two integrated PROFIBUS DP ports: one standard DP and one dedicated DP (drive) interface, so you can run the motion bus on a separate network from the plant I/O scan. ## Programming Languages and Engineering Toolchain This CPU supports LAD, FBD, STL, SCL, GRAPH, CFC, and HiGraph. The engineering software is STEP 7 V5.2 SP1 or higher with the S7 Technology option package. ## Memory, I/O Capacity, and Expansion The CPU provides 244 bytes each for process-image inputs and outputs, with a total of 16 I/O modules addressable across the rack. The work memory size is max. 16 kbyte, and the retentive memory must be restarted at each restart — not battery-backed in the traditional sense. The FM (function module) count is 8, and the CPU supports forcing of variables (inputs, outputs, memory bits, DBs, times, counters) for commissioning. Expansion is not expandable beyond the standard S7-300 rack limit. ## Communication Interfaces and Routing The CPU has an isolated RS 485 interface on the MPI/DP port, but MPI routing is not supported. For PROFIBUS DP, up to 2 CPs can be added; for Ethernet (LAN), up to 10 CPs; for point-to-point (PtP), up to 8 CPs. The CPU can act as a DP client via a CP and a loadable FB, and as a DP server. PROFINET routing is not available.","metaTitle":"Siemens 6ES7315-6TG10-0AB0 CPU 315T-2 DP, 2x DP","metaDescription":"Siemens 6ES7315-6TG10-0AB0 CPU 315T-2 DP with 2 integrated DP ports, 244 byte I/O, FM 8, CFC, FBD, LAD, SCL, STL, GRAPH, HiGraph. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"1 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","DPV1":"No","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"160 mm","Alarms":"No","Height":"125 mm","Inputs":"244 byte","Number":"1","Preset":"150 ms","RS 485":"Yes","STEP 7":"Yes; V5.2 SP1 or higher and S7 Technology option package","via CP":"2; for DP","CP, LAN":"10","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"16","Present":"Yes","Routing":"No","Isolated":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","Functions":"for technology functions, e.g. high-speed cam switch signals","HiGraph®":"Yes","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Expandable":"No","Integrated":"2; 1 DP and 1 DP (drive)","Size, max.":"16 kbyte","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"1 ms","Racks, max.":"1","SYNC/FREEZE":"No","Single step":"Yes","Upper Limit":"6 000 ms","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"244 kbyte; 244 byte per DP slave","Number, max.":"2 048 byte","Status block":"Yes","in AS, slave":"Yes","2-Wire Sensor":"No","Outputs, max.":"244 kbyte; 244 byte per DP slave","Plug-in (MMC)":"Yes","in AS, master":"Yes","to MPI, slave":"Yes","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","Shielded, Max.":"1 000 m","to MPI, master":"Yes","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"750 g","lifecycle_stage":"eol_hot","Firmware version":"CPU: V2.3.1, integrated technology: V3.1.1","Of Which Central":"64","Power loss, typ.":"6 W","Rated value (DC)":"24 V","S7 communication":"No","Unshielded, Max.":"600 m","Backup time, max.":"10 y; Data retention on the MMC (after last programming)","PROFIBUS DP slave":"No","Address area, max.":"32","Forcing, variables":"Inputs, outputs","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"Yes; DP(DRIVE)-Master","Per Priority Class":"8","Retentivity preset":"MB 0 to MB 15","up to 40 °C, max.":"3 A","up to 60 °C, max.":"3 A","At \"0\" To \"1\", Max.":"10 µs; Typical","At \"1\" To \"0\", Max.":"10 µs; Typical","Number/Number range":"0","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V 5.3 SP1 or higher and S7-Technology option package V2.0","Diagnostics function":"No","For Signal \"0\", Max.":"3 V","For Signal \"1\", Min.":"2L+ (-2,5 V)","For Signal \"1\", Typ.":"7 mA","HW functional status":"01","Inrush current, typ.":"2.5 A","Isolation tested with":"500 V DC","Number of breakpoints":"2","Number of startup OBs":"1","Retentivity available":"Yes; MB 0 to MB 2 047","Modules per rack, max.":"8","Retentivity adjustable":"Yes","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","Number of entries, max.":"100","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"180 byte; With PUT/GET","For Bit Operations, Max.":"0.1 µs","For Bit Operations, Typ.":"0.1 µs","Number of GD loops, max.":"8","Number of blocks (total)":"1 024","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"4","Number of free cycle OBs":"1","Number of time alarm OBs":"1","Per Priority Class, Max.":"1 024 byte","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Size of GD packets, max.":"22 byte","For Word Operations, Typ.":"0.2 µs","Global data communication":"No","Number of DP slaves, max.":"32","Number of delay alarm OBs":"1","Number of digital outputs":"8","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.2 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"No","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Controlling a digital input":"No","Number of process alarm OBs":"1","Process diagnostic messages":"Yes","Reverse polarity protection":"No","S7 communication, as client":"Yes; Via CP and loadable FB","S7 communication, as server":"Yes","usable for OP communication":"15","usable for PG communication":"15","Retentive And Synchronizable":"Yes","Retentive Data Area In Total":"1 024 (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC that you use","System function blocks (SFB)":"see instruction list","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Number of cyclic interrupt OBs":"1","For Redundant Control Of A Load":"No","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"30","For Fixed Point Arithmetic, Typ.":"2 µs","Number of asynchronous error OBs":"1","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","usable for S7 basic communication":"12","For Floating Point Arithmetic, Typ.":"3 µs","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"No","Number of GD packets, receiver, max.":"8","For Signal \"0\" Residual Current, Max.":"0.3 mA","adjustable for OP communication, max.":"15","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"15","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","Status indicator digital input (green)":"Yes","Number of GD packets, transmitter, max.":"8","Status indicator digital output (green)":"Yes","simultaneously active Alarm-S blocks, max.":"40","Limitation of inductive shutdown voltage to":"2L+ (-48 V)","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"12","adjustable for S7 basic communication, min.":"0","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"64 byte; as server","Power supply to interface (15 to 30 V DC), max.":"200 mA","Current consumption (in no-load operation), typ.":"200 mA","Direct data exchange (slave-to-slave communication)":"Yes","Number of login stations for message functions, max.":"16; Depending on the configured connections for PG/OP and S7 basic communication","Data management on MMC (after last programming), min.":"10 y","for signal \"1\" permissible range for 0 to 60 °C, max.":"0.6 A","for signal \"1\" permissible range for 0 to 60 °C, min.":"5 mA","External Protection For Power Supply Lines (Recommendation)":"2 A min."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,852.93","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=202945&mlfb=6ES7315-6TG10-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7315-6TG10-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Is the 6ES7315-6TG10-0AB0 compatible with standard S7-300 racks?","answer":"Yes, it mounts in the standard S7-300 DIN-rail rack and uses the same backplane bus. The dimensions are 160 mm width, 125 mm height, and 130 mm depth."},{"question":"How can I order the Siemens 6ES7315-6TG10-0AB0?","answer":"This CPU is sourced to order against your RFQ. Availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7315-6TG10-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7315-6TG10-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}