{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7317-2EK13-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7317-2EK13-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7317-2EK13-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7317-2EK13-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"***Spare part*** SIMATIC S7-300 CPU 317-2 PN/DP, Central processing unit with 1 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required","salesMarkdown":null,"metaTitle":"6ES7317-2EK13-0AB0","metaDescription":"***Spare part*** SIMATIC S7-300 CPU 317-2 PN/DP, Central processing unit with 1 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"1 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","UDP":"Yes; via integrated PROFINET interface and loadable FBs","DPV1":"No","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"80 mm","Height":"125 mm","Inputs":"244 byte","Number":"4","Preset":"No retentivity","RS 485":"Yes","STEP 7":"Yes; V5.4 SP2 or higher","TCP/IP":"Yes; via integrated PROFINET interface and loadable FBs","via CP":"4","CP, LAN":"10","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"32","Present":"Yes","Routing":"Yes","Isolated":"Yes","As Client":"Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB","As Server":"Yes","HiGraph®":"Yes","PROFIsafe":"No","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"No","Expandable":"No","Integrated":"1","Size, max.":"4 096 byte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"10 ms","Racks, max.":"4","SYNC/FREEZE":"Yes","Send cycles":"1 ms","Single step":"Yes","Upper Limit":"9 990 s","Equidistance":"Yes","Inputs, max.":"8 kbyte","Number, max.":"2 048; Number range: 0 to 2047","PROFINET CBA":"Yes","Status block":"Yes","in AS, slave":"Yes","to DP, slave":"Yes","Outputs, max.":"8 kbyte","Plug-in (MMC)":"Yes","Updating time":"1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)","in AS, master":"Yes","to DP, master":"Yes; With DP slave only slave clock","to MPI, slave":"Yes","Interface type":"PROFINET","Nesting levels":"8","to MPI, master":"Yes","Inputs, default":"256 byte","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"460 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","Firmware version":"V2.6","Isochronous mode":"Yes; OB 61","Of Which Central":"256","Outputs, default":"256 byte","Power loss, typ.":"3.5 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","S7 communication":"Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32","Data length, max.":"1 472 byte","PROFIBUS DP slave":"No","Address area, max.":"32","Forcing, variables":"Inputs, outputs","Inputs, adjustable":"2 048 byte","PROFIBUS DP master":"No","PROFINET IO Device":"No","Per Priority Class":"16","Retentivity preset":"Yes","Usable For Routing":"X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.","Cyclic Transmission":"Yes","Data record routing":"No","Number/Number range":"0 to 3","Outputs, adjustable":"2 048 byte","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V5.4 SP2","on Ethernet via NTP":"Yes; As client","Acyclic Transmission":"Yes","HW functional status":"01","ISO-on-TCP (RFC1006)":"Yes; via integrated PROFINET interface and loadable FBs","Inrush current, typ.":"2.5 A","Number of breakpoints":"2","Number of connections":"32","Number of startup OBs":"1; OB 100","Open IE communication":"Yes; Via TCP/IP, ISO on TCP, and UDP","Retentivity available":"Yes; From MB 0 to MB 4 095","Modules per rack, max.":"8","Number of HTTP clients":"5","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","Number of entries, max.":"500","Status/control variable":"Yes","Transmission rate, max.":"100 Mbit/s","User data per job, max.":"See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)","For Bit Operations, Typ.":"0.05 µs","Number of DPV1 alarm OBs":"3; OB 55, 56, 57","Number of GD loops, max.":"8","Number of blocks (total)":"2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Of Which Powerfail-Proof":"100","Per Priority Class, Max.":"1 024 byte","Size of GD packets, max.":"22 byte","integrated channels (AI)":"0","integrated channels (AO)":"0","integrated channels (DI)":"0","integrated channels (DO)":"0","For Word Operations, Typ.":"0.2 µs","Global data communication":"No","Number of DP slaves, max.":"124","Number of delay alarm OBs":"2; OB 20, 21","Number of variables, max.":"10","Point-to-point connection":"No","Automatic Baud Rate Search":"Yes; only with passive interface","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"2","Number of connections, max.":"8","Number of process alarm OBs":"1; OB 40","Process diagnostic messages":"Yes","S7 communication, as client":"No","S7 communication, as server":"Yes","User data consistency, max.":"254 byte","usable for OP communication":"31","usable for PG communication":"31","usable for S7 communication":"16","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Number of PROFINET interfaces":"1","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","reserved for S7 communication":"0","Number of cyclic interrupt OBs":"4; OB 32, 33, 34, 35","Number of isochronous mode OBs":"1; OB 61","Number of expansion units, max.":"3","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","Total Number Of Instances, Max.":"32","For Fixed Point Arithmetic, Typ.":"0.2 µs","Number of asynchronous error OBs":"6; OB 80, 82, 83, 85, 86, 87","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","Current consumption (rated value)":"650 mA","Number of subprocess images, max.":"1","usable for S7 basic communication":"30","For Floating Point Arithmetic, Typ.":"1 µs","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","Number of GD packets, receiver, max.":"8","Output current of the interface, max.":"0 mA","adjustable for OP communication, max.":"31","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"31","adjustable for PG communication, min.":"1","adjustable for S7 communication, max.":"16","adjustable for S7 communication, min.":"0","Number of connectable IO Devices, max.":"128","Number of GD packets, transmitter, max.":"8","Setpoint for the CPU communication load":"50 %","Automatic Detection Of Transmission Rate":"Yes; 10/100 Mbit/s","Behavior of the clock following POWER-ON":"Clock continues running after POWER OFF","Number of industrial Ethernet interfaces":"1","Data length for connection type 01H, max.":"1 460 byte","Data length for connection type 11H, max.":"8 192 byte","simultaneously active Alarm-S blocks, max.":"60","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"30","adjustable for S7 basic communication, min.":"0","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)","Current consumption (in no-load operation), typ.":"100 mA","Direct data exchange (slave-to-slave communication)":"Yes","Number of login stations for message functions, max.":"32; Depending on the configured connections for PG/OP and S7 basic communication","Data management on MMC (after last programming), min.":"10 y","Behavior of the clock following expiry of backup period":"the clock continues at the time of day it had when power was switched off","number of remote connection partners / with PROFINET CBA":"32","Retentive data area (incl. timers, counters, flags), max.":"256 kbyte","External Protection For Power Supply Lines (Recommendation)":"2 A min.","number of coupled PROFIBUS devices / with PROFIBUS functionality":"16","Number of DP slaves that can be simultaneously activated/deactivated, max.":"4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,480.19 – $3,571.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=532382&mlfb=6ES7317-2EK13-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7317-2EK13-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7317-2EK13-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7317-2EK13-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}