{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7317-6TJ10-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7317-6TJ10-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7317-6TJ10-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7317-6TJ10-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-300 317T-2 DP technology CPU, order code 6ES7317-6TJ10-0AB0, 8 FM technology functions, CFC support, 160 x 125 x 130 mm.","salesMarkdown":"## Technology CPU for cam-switch and drive applications The Siemens 6ES7317-6TJ10-0AB0 is a SIMATIC S7-300 317T-2 DP technology CPU — the 'T' designates it for closed-loop motion and cam-switch tasks that a standard 317-2 DP cannot handle in deterministic cycle time. It carries 8 FM technology functions purpose-built for high-speed cam switch signals and drive control, making it the right pick when a line needs position-triggered outputs at takt rate, not just logic scans. ## Programming and engineering environment Programmable in LAD, FBD, STL, SCL, GRAPH, HiGraph, and CFC — the CFC support is key for drive-control loops where you wire function blocks instead of ladder logic. Requires STEP 7 V5.2 SP1 or higher with the S7 Technology option package; the technology package adds the cam-switch and positioning blocks the standard 317 cannot compile.","metaTitle":"Siemens 6ES7317-6TJ10-0AB0 317T-2 DP PLC","metaDescription":"Siemens 317T-2 DP PLC with 8 FM technology functions for cam switches and drive control. Supports CFC, SCL, STL. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"1 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","DPV1":"No","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"160 mm","Alarms":"No","Height":"125 mm","Inputs":"244 byte","Number":"4","Preset":"No retentivity","STEP 7":"Yes; V5.2 SP1 or higher and S7 Technology option package","via CP":"2","24 V DC":"Yes","CP, LAN":"10","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"32","Physics":"RS 485","Present":"Yes","Routing":"No","Isolated":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","Functions":"for technology functions, e.g. high-speed cam switch signals","HiGraph®":"Yes","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"No","Expandable":"No","Integrated":"2","Size, max.":"64 kbyte","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"48 Ω","Racks, max.":"1","SYNC/FREEZE":"No","Single step":"Yes","Upper Limit":"4 kΩ","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"244 kbyte","Number, max.":"4 096 byte","Status block":"Yes","in AS, slave":"Yes","2-Wire Sensor":"No","Outputs, max.":"244 kbyte","Plug-in (MMC)":"Yes; min. 4 MB required","in AS, master":"Yes","to MPI, slave":"Yes","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","Shielded, Max.":"1 000 m","to MPI, master":"Yes","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"750 g","lifecycle_stage":"eol_hot","Firmware version":"CPU: V2.1.0, integrated technology: V3.0.1","Of Which Central":"64","Power loss, typ.":"6 W","Rated value (DC)":"24 V","S7 communication":"No","Unshielded, Max.":"600 m","Backup time, max.":"10 y; Data retention on the MMC (after last programming)","PROFIBUS DP slave":"No","Address area, max.":"32","Forcing, variables":"Inputs, outputs","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"Yes; DP(DRIVE)-Master","Per Priority Class":"16","Retentivity preset":"MB 0 to MB 15","up to 40 °C, max.":"3 mA","up to 60 °C, max.":"3 mA","At \"0\" To \"1\", Max.":"10 µs; Typical","At \"1\" To \"0\", Max.":"10 µs; Typical","Number/Number range":"0 to 3","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V 5.2 SP1 or higher with HF1 and S7-Technology option package","Diagnostics function":"No","For Signal \"0\", Max.":"3 V","For Signal \"1\", Min.":"2L+ (-2,5 V)","For Signal \"1\", Typ.":"7 mA","HW functional status":"02","Inrush current, typ.":"2.5 A","Isolation tested with":"500 V DC","Number of breakpoints":"2","Retentivity available":"Yes; From MB 0 to MB 4 095","Modules per rack, max.":"8","Retentivity adjustable":"Yes","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","Number of entries, max.":"100","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"180 byte; With PUT/GET","For Bit Operations, Typ.":"0.05 µs","Number of GD loops, max.":"8","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"4","Per Priority Class, Max.":"1 024 byte","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Size of GD packets, max.":"22 byte","For Word Operations, Typ.":"0.2 µs","Global data communication":"No","Number of DP slaves, max.":"32","Number of digital outputs":"8","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.2 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"No","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Controlling a digital input":"No","Process diagnostic messages":"Yes","Reverse polarity protection":"No","S7 communication, as client":"Yes; Via CP and loadable FB","S7 communication, as server":"Yes","usable for OP communication":"31","usable for PG communication":"31","Retentive And Synchronizable":"Yes","Retentive Data Area In Total":"2 048 (DBs, FCs, FBs). The maximum number of loadable blocks can be reduced by the MMC that you use","System function blocks (SFB)":"see instruction list","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","For Redundant Control Of A Load":"No","Of Which Status Variables, Max.":"30","For Fixed Point Arithmetic, Typ.":"0.2 µs","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","usable for S7 basic communication":"30","For Floating Point Arithmetic, Typ.":"1 µs","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"No","Number of GD packets, receiver, max.":"8","For Signal \"0\" Residual Current, Max.":"0.3 mA","adjustable for OP communication, max.":"31","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"31","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","Status indicator digital input (green)":"Yes","Number of GD packets, transmitter, max.":"8","Status indicator digital output (green)":"Yes","simultaneously active Alarm-S blocks, max.":"60","Limitation of inductive shutdown voltage to":"2L+ (-48 V)","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"30","adjustable for S7 basic communication, min.":"0","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"160 byte; as server","Power supply to interface (15 to 30 V DC), max.":"200 mA","Current consumption (in no-load operation), typ.":"200 mA","Direct data exchange (slave-to-slave communication)":"Yes","Number of login stations for message functions, max.":"32; Depending on the configured connections for PG/OP and S7 basic communication","for signal \"1\" permissible range for 0 to 60 °C, max.":"0.6 A","for signal \"1\" permissible range for 0 to 60 °C, min.":"5 mA","External Protection For Power Supply Lines (Recommendation)":"2 A min."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,666.62","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=171639&mlfb=6ES7317-6TJ10-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7317-6TJ10-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Does the 6ES7317-6TJ10-0AB0 support technology functions and drive control?","answer":"Yes. The 8 FM technology functions are designed for high-speed cam switch signals and drive control applications. The CFC support allows block-based programming for closed-loop drive control."},{"question":"How can I order 6ES7317-6TJ10-0AB0 or check stock?","answer":"Submit an RFQ for your BOM quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7317-6TJ10-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7317-6TJ10-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}