{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7317-6TK13-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7317-6TK13-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7317-6TK13-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7317-6TK13-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens CPU 317T-2 DP, order code 6ES7317-6TK13-0AB0, SFB type, FM 8 slots, CFC supported, 0-60°C, 160×125×130 mm.","salesMarkdown":"## CPU 317T-2 DP for high-speed technology functions The Siemens 6ES7317-6TK13-0AB0 is a CPU 317T-2 DP of the SFB type, built for technology functions like high-speed cam switch signals. It carries 8 FM slots, so you can stack function modules for motion or positioning without eating up the main rack. CFC, FBD, LAD, STL, SCL, and GRAPH are all supported — pick your programming language. Operating range is 0 to 60 °C, which is standard for a ventilated panel; keep it out of the direct sun or hot motor alley. The I2t rating of 1 A²·s tells you the short-circuit withstand of the internal power supply — a fault downstream that exceeds that energy level will cook the module, so size your branch protection accordingly. It has 244 bytes each of process-input and process-output image, which is generous for a mid-range CPU; you can map a couple of analog cards and a bunch of digital without running out of I/O space. RS-485 is onboard for point-to-point drives or barcode readers, and you can add up to 10 CPs for LAN, 8 for PtP, and 2 for DP via CP modules. No MPI, no PROFIsafe, no routing — this is a dedicated technology CPU, not a safety controller. The module measures 160 mm wide by 125 mm high by 130 mm deep — standard SIMATIC S7-300 footprint. The 8 FM slots accept technology modules that share the backplane bus, so plan your slot layout before wiring. Forcing is supported, which is handy during commissioning but lock it out in production.","metaTitle":"Siemens 6ES7317-6TK13-0AB0 CPU 317T-2 DP, SFB type, FM 8, 0-","metaDescription":"Siemens 6ES7317-6TK13-0AB0 CPU 317T-2 DP, SFB type with FM 8 slots, CFC supported, 0-60°C operating range, 160x125x130 mm. Available to order, quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"1 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","DPV1":"No","Max.":"60 °C","Min.":"0 °C","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"160 mm","Alarms":"No","Height":"125 mm","Inputs":"244 byte","Number":"4","Preset":"No retentivity","RS 485":"Yes","STEP 7":"Yes","via CP":"2; for DP","CP, LAN":"10","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"32","Present":"Yes","Routing":"No","GSD file":"http://support.automation.siemens.com in Product Support area","Isolated":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","Functions":"for technology functions, e.g. high-speed cam switch signals","HiGraph®":"Yes","PROFIsafe":"No","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Expandable":"No","Integrated":"2; 1 DP and 1 DP (drive)","Size, max.":"4 096 byte","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"1 ms","Racks, max.":"1","SYNC/FREEZE":"No","Single step":"Yes","Upper Limit":"6 000 ms","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"244 byte","Number, max.":"see instruction list","Status block":"Yes","in AS, slave":"Yes","to DP, slave":"Yes","2-Wire Sensor":"No","Outputs, max.":"244 byte","Plug-in (MMC)":"Yes","in AS, master":"Yes","to DP, master":"Yes","to MPI, slave":"Yes","Digital inputs":"66","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","Shielded, Max.":"1 000 m","to MPI, master":"Yes","Digital outputs":"66","Inputs, default":"256 byte","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"750 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","Firmware version":"CPU: V2.7, integrated technology: V4.1.5","Isochronous mode":"Yes","Of Which Central":"64","Outputs, default":"256 byte","Power loss, typ.":"6 W","Rated value (DC)":"24 V","S7 communication":"No","PROFIBUS DP slave":"No","Address area, max.":"32","Forcing, variables":"Inputs, outputs","Inputs, adjustable":"2 048 byte","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"Yes; DP(DRIVE)-Master","Per Priority Class":"16","Retentivity preset":"Yes","Usable For Routing":"8; additional","up to 40 °C, max.":"3 A","up to 60 °C, max.":"3 A","At \"0\" To \"1\", Max.":"10 µs; Typical","At \"1\" To \"0\", Max.":"10 µs; Typical","Number/Number range":"0 to 3","Outputs, adjustable":"2 048 byte","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V5.4 + SP5 (and higher) and Optional package S7-Technology V4.2","Diagnostics function":"No","For Signal \"0\", Max.":"3 V; (2L+)","For Signal \"1\", Min.":"Rated voltage -2.5 V","For Signal \"1\", Typ.":"7 mA","HW functional status":"01","Inrush current, typ.":"2.5 A","Isolation tested with":"500 V DC","Number of breakpoints":"2","Number of connections":"32","Number of startup OBs":"1; OB 100","Retentivity available":"Yes; From MB 0 to MB 4 095","Modules per rack, max.":"8","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s","Number of analog inputs":"0","Number of entries, max.":"100","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)","For Bit Operations, Max.":"0.05 µs","For Bit Operations, Typ.":"0.05 µs","Number of DPV1 alarm OBs":"3; OB 55, 56, 57","Number of GD loops, max.":"8","Number of analog outputs":"0","Number of blocks (total)":"2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"4","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Per Priority Class, Max.":"1 024 byte","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Size of GD packets, max.":"22 byte","For Word Operations, Typ.":"0.2 µs","Global data communication":"No","Number of DP slaves, max.":"64","Number of delay alarm OBs":"2; OB 20, 21","Number of digital outputs":"8","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.2 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"No","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Controlling a digital input":"No","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"2","Number of process alarm OBs":"1; OB 40","Of Which High-Speed Outputs":"8","Process diagnostic messages":"Yes","Reverse polarity protection":"No; (2L+)","S7 communication, as client":"No; but via CP and loadable FB","S7 communication, as server":"Yes; Connection configured on one side only","usable for OP communication":"31","usable for PG communication":"31","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Number of PROFINET interfaces":"0","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Cycle Monitoring Time / Preset":"150 ms","Number of cyclic interrupt OBs":"4; OB 32, 33, 34, 35","Number of isochronous mode OBs":"1; OB 61","For Redundant Control Of A Load":"No","Number of expansion units, max.":"0","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","For Fixed Point Arithmetic, Typ.":"0.2 µs","Number of asynchronous error OBs":"5; OB 80, 82, 85, 86, 87","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","Number of subprocess images, max.":"1","usable for S7 basic communication":"30","For Floating Point Arithmetic, Typ.":"1 µs","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","Number of GD packets, receiver, max.":"8","For Signal \"0\" Residual Current, Max.":"0.3 mA","Output current of the interface, max.":"200 mA","adjustable for OP communication, max.":"31","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"31","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","Status indicator digital input (green)":"Yes","Number of GD packets, transmitter, max.":"8","Status indicator digital output (green)":"Yes","Number of industrial Ethernet interfaces":"0","Number of technology synchronous alarm OBs":"1; OB 65","simultaneously active Alarm-S blocks, max.":"60","Limitation of inductive shutdown voltage to":"48 V","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"30","adjustable for S7 basic communication, min.":"0","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"76 byte; 76 bytes (with X_SEND or X_RCV), 76 bytes (with X_PUT or X_GET as server)","Current consumption (in no-load operation), typ.":"200 mA","Of Which Inputs Usable For Technological Functions":"4","Direct data exchange (slave-to-slave communication)":"Yes","Number of login stations for message functions, max.":"32; Depending on the configured connections for PG/OP and S7 basic communication","Data management on MMC (after last programming), min.":"10 a","for signal \"1\" permissible range for 0 to 60 °C, max.":"0.6 A","for signal \"1\" permissible range for 0 to 60 °C, min.":"5 mA","Retentive data area (incl. timers, counters, flags), max.":"256 kbyte","External Protection For Power Supply Lines (Recommendation)":"2 A min."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,857.50","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/70864f9f920e4de664d9764966a1ea86.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=50743&mlfb=6ES7317-6TK13-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7317-6TK13-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What is 6ES7317-6TK13-0AB0's listed FM (8) on this component line?","answer":"It carries 8 FM slots for function modules, letting you add technology-specific processing without occupying the main rack."},{"question":"What is 6ES7317-6TK13-0AB0's listed CFC (Yes) on this component line?","answer":"CFC (Continuous Function Chart) is supported, so you can program signal-flow diagrams directly on this CPU."},{"question":"What compliance documentation does this brand provide for 6ES7317-6TK13-0AB0?","answer":"The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. The GSD file for PROFIBUS integration is available on Siemens' Product Support area."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7317-6TK13-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7317-6TK13-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}