{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7317-7TK10-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7317-7TK10-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7317-7TK10-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7317-7TK10-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-300 CPU 317-7TK DP, SFB, FM 8, 244 byte I/O, PROFINET IRT, STEP 7 V5.5 SP2+.","salesMarkdown":"The Siemens 6ES7317-7TK10-0AB0 is a SIMATIC S7-300 CPU 317-7TK DP, classified as an SFB (Safety Fault-tolerant) type. It carries an FM 8 rating, meaning it supports up to 8 technology function modules for tasks like high-speed cam switch signals. The CPU provides 244 bytes each of process input and output image, giving it a substantial I/O footprint for a mid-range S7-300 controller. This CPU integrates a PROFINET interface with IRT (Isochronous Real-Time) support, enabling deterministic communication for motion control and high-speed applications. It also supports UDP and TCP/IP via the integrated PROFINET interface and loadable function blocks, so it can talk directly to drives, vision systems, or SCADA without an extra CP. Programming is handled through STEP 7 V5.5 SP2 or higher, with the S7-Technology option package V4.2 SP3 required for technology functions. The CPU supports LAD, FBD, STL, SCL, GRAPH, CFC, and HiGraph languages, giving flexibility across engineering teams. ## Key specs that matter for fit The I2t rating of 1 A²·s is the thermal energy the CPU's internal electronics can withstand during a short-circuit event — useful when coordinating with upstream breakers in a panel. It has 4 integrated counters with a preset value of 10, and supports up to 32 modules overall. Forcing is supported, which is handy during commissioning to override outputs without changing the program. The CPU is isolated, meaning the logic and I/O circuits are galvanically separated from the backplane. PROFIsafe is not supported on this CPU, so if you need fail-safe communication to safety I/O, you'll need a different processor. MPI and DPV1 are also not available — communication is PROFINET-native. RS 485 is present, so you can still hook up legacy drives or HMI panels via a point-to-point link. ## Panel integration and expansion The CPU measures 120 mm wide, 125 mm high, and 130 mm deep — standard S7-300 form factor that snaps onto a DIN rail. It supports up to 8 CPs for LAN and 8 CPs for PtP communication, plus 2 CPs for DP, so you can expand the network interfaces significantly without changing the CPU. Routing is supported, which means you can access PROFIBUS or PROFINET devices through the CPU's own interface from the engineering station. A GSD file is available from Siemens support for integrating the CPU into a PROFINET master system.","metaTitle":"Siemens 6ES7317-7TK10-0AB0 SIMATIC S7-300 CPU 317-7TK DP, SF","metaDescription":"Siemens 6ES7317-7TK10-0AB0 CPU 317-7TK DP, SFB type, FM 8, 244-byte I/O, PROFINET IRT, STEP 7 V5.5 SP2+. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"1 A²·s","IRT":"Yes","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","UDP":"Yes; via integrated PROFINET interface and loadable FBs","DPV1":"No","Max.":"60 °C","Min.":"0 °C","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"120 mm","Alarms":"No","Height":"125 mm","Inputs":"244 byte","Number":"4","Preset":"10","RS 485":"Yes","STEP 7":"Yes; STEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3","TCP/IP":"Yes; via integrated PROFINET interface and loadable FBs","via CP":"2; for DP","CP, LAN":"8","CP, PtP":"8","Forcing":"Yes","Outputs":"244 byte","Overall":"32","Present":"Yes","Routing":"Yes","GSD file":"http://support.automation.siemens.com in Product Support area","Isolated":"Yes","As Client":"Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB","As Server":"Yes","Functions":"for technology functions, e.g. high-speed cam switch signals","HiGraph®":"Yes","PROFIsafe":"No","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes; From 10 to 499","Expandable":"No","Integrated":"2; 1 DP and 1 DP (drive)","Size, max.":"4 096 byte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"48 Ω","PROFIenergy":"Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device","Racks, max.":"1","SYNC/FREEZE":"No","Send cycles":"250 µs, 500 µs, 1 ms, 2 ms, 4 ms","Single step":"Yes","Upper Limit":"4 kΩ","Autocrossing":"Yes","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"1 440 byte; Per IO Controller with shared device","Number, max.":"64","Status block":"Yes; Up to 2 simultaneously","in AS, slave":"Yes","to DP, slave":"Yes; Only time-of-day slave","2-Wire Sensor":"No","Outputs, max.":"1 440 byte; Per IO Controller with shared device","Plug-in (MMC)":"Yes","Shared device":"Yes","Updating time":"250 µs to 512 ms (depending on the operating mode, see Manual \"S7-300 CPU 31xC and CPU 31x, technical Data\" for more details)","in AS, master":"Yes","to DP, master":"Yes","to MPI, slave":"Yes","Digital inputs":"66","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"PROFINET","Nesting levels":"8","Shielded, Max.":"1 000 m","to MPI, master":"Yes","Autonegotiation":"Yes","Can Be Read Out":"Yes","Digital outputs":"66","Inputs, default":"256 byte","Number of ports":"2","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"640 g","Without Battery":"Yes; Program and data","lifecycle_stage":"eol_hot","Block encryption":"Yes; With S7 block Privacy","Firmware version":"CPU: V3.2; integrated technology V4.1.5","Isochronous mode":"No","Media redundancy":"Yes","Of Which Central":"64","Outputs, default":"256 byte","Power loss, typ.":"7.5 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","S7 communication":"Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32","Data length, max.":"1 472 byte","Integrated Switch":"Yes","PROFIBUS DP slave":"No","Address area, max.":"32","Forcing, variables":"Inputs, outputs","Inputs, adjustable":"8 192 byte","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"No","PROFINET IO Device":"Yes; Also simultaneously with IO Controller functionality","Per Priority Class":"16","Retentivity preset":"Yes","Usable For Routing":"X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.","up to 40 °C, max.":"4 A","up to 60 °C, max.":"3 A","At \"0\" To \"1\", Max.":"10 µs; Typical","At \"1\" To \"0\", Max.":"10 µs; Typical","Data record routing":"Yes","Number/Number range":"0 to 3","Outputs, adjustable":"8 192 byte","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Prioritized startup":"Yes","Programming package":"STEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3","on Ethernet via NTP":"Yes; As client","Diagnostics function":"No","For Signal \"0\", Max.":"3 V; (2L+)","For Signal \"1\", Min.":"Rated voltage -2.5 V","For Signal \"1\", Typ.":"7 mA","HW functional status":"01","ISO-on-TCP (RFC1006)":"Yes; via integrated PROFINET interface and loadable FBs","Inrush current, typ.":"6.5 A","Isolation tested with":"500 V DC","Number of breakpoints":"4; without continuation","Number of startup OBs":"1; OB 100","Open IE communication":"Yes; Via TCP/IP, ISO on TCP, and UDP","Retentivity available":"Yes; From MB 0 to MB 4 095","User-defined websites":"Yes","Modules per rack, max.":"8","Number of HTTP clients":"5","Of Which In Line, Max.":"128","PROFINET IO Controller":"Yes; Also simultaneously with IO-Device functionality","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s; Typ.: 2 s","Number of analog inputs":"0","Number of entries, max.":"500","Status/control variable":"Yes","Transmission rate, max.":"100 Mbit/s","User data per job, max.":"See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)","For Bit Operations, Typ.":"0.025 µs","Number of DPV1 alarm OBs":"3; OB 55, 56, 57","Number of GD loops, max.":"8","Number of analog outputs":"0","Number of blocks (total)":"2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"4","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Of Which Powerfail-Proof":"100; Only the last 100 entries are retained","Per Priority Class, Max.":"32 768 byte; Max. 2048 bytes per block","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Size of GD packets, max.":"22 byte","Switching accuracy (+/-)":"70 µs","For Word Operations, Typ.":"0.03 µs","Global data communication":"No","Number of DP slaves, max.":"64","Number of delay alarm OBs":"2; OB 20, 21","Number of digital outputs":"8","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.2 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"Yes; only with passive interface","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Controlling a digital input":"No","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"2","Number of connections, max.":"16","Number of process alarm OBs":"1; OB 40","Of Which High-Speed Outputs":"8","Process diagnostic messages":"Yes","Reverse polarity protection":"No; 2L+","S7 communication, as client":"No","S7 communication, as server":"Yes; Connection configured on one side only","User data consistency, max.":"1 024 byte","usable for OP communication":"31","usable for PG communication":"31","usable for S7 communication":"16","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Number of PROFINET interfaces":"1","User data per submodule, max.":"1 024 byte","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","reserved for S7 communication":"0","Keep-alive function, supported":"Yes","Number of cyclic interrupt OBs":"4; OB 32, 33, 34, 35","Number of isochronous mode OBs":"1; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)","For Redundant Control Of A Load":"No","Number of expansion units, max.":"0","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","Total Number Of Instances, Max.":"32","For Fixed Point Arithmetic, Typ.":"0.04 µs","Number of asynchronous error OBs":"6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","Current consumption (rated value)":"1 050 mA","Number of subprocess images, max.":"1; With PROFINET IO, the length of the user data is limited to 1600 bytes","usable for S7 basic communication":"30","Of which IO devices with IRT, max.":"64","For Floating Point Arithmetic, Typ.":"0.16 µs","Number of IO Devices per tool, max.":"8","Switchover time on line break, typ.":"200 ms; PROFINET MRP","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","Number of GD packets, receiver, max.":"8","Number of stations in the ring, max.":"50","Activation/deactivation of IO Devices":"Yes","For Signal \"0\" Residual Current, Max.":"0.3 mA","Output current of the interface, max.":"200 mA","adjustable for OP communication, max.":"31","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"31","adjustable for PG communication, min.":"1","adjustable for S7 communication, max.":"16","adjustable for S7 communication, min.":"0","Between The Channels And Backplane Bus":"Yes","Device replacement without swap medium":"Yes","Number of connectable IO Devices, max.":"128","Status indicator digital input (green)":"Yes","Number of GD packets, transmitter, max.":"8","Number of entries readable in RUN, max.":"499","Status indicator digital output (green)":"Yes","Automatic Detection Of Transmission Rate":"Yes; 10/100 Mbit/s","Behavior of the clock following POWER-ON":"Clock continues running after POWER OFF","Number of industrial Ethernet interfaces":"1","Data length for connection type 01H, max.":"1 460 byte","Data length for connection type 11H, max.":"32 768 byte","Local port numbers used at the system end":"0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535","Change of IP address at runtime, supported":"Yes","Number of technology synchronous alarm OBs":"1; OB 65","simultaneously active Alarm-S blocks, max.":"300","Limitation of inductive shutdown voltage to":"48 V","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"30","adjustable for S7 basic communication, min.":"0","Number of connectable IO Devices for RT, max.":"128","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)","Several Passive Connections Per Port, Supported":"Yes","Current consumption (in no-load operation), typ.":"230 mA","Number of IO Controllers with shared device, max.":"2","Of Which Inputs Usable For Technological Functions":"4","Direct data exchange (slave-to-slave communication)":"Yes","Number of IO devices with prioritized startup, max.":"32","Number of login stations for message functions, max.":"32; Depending on the configured connections for PG/OP and S7 basic communication","Data management on MMC (after last programming), min.":"10 a","for signal \"1\" permissible range for 0 to 60 °C, max.":"0.6 A","for signal \"1\" permissible range for 0 to 60 °C, min.":"5 mA","Behavior of the clock following expiry of backup period":"the clock continues at the time of day it had when power was switched off","Retentive data area (incl. timers, counters, flags), max.":"256 kbyte","External Protection For Power Supply Lines (Recommendation)":"2 A min.","IO Devices changing during operation (partner ports), supported":"Yes","Number of DP slaves that can be simultaneously activated/deactivated, max.":"8","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,046.98 – $10,868.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ed97a6676269651b5d54a4b9e7a97080.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=14910&mlfb=6ES7317-7TK10-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7317-7TK10-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What is 6ES7317-7TK10-0AB0's listed FM (8) on this component line?","answer":"The FM 8 rating means the CPU supports up to 8 technology function modules, such as high-speed cam switch signal processing. This is a key differentiator from standard S7-300 CPUs that may support fewer or no FM modules."},{"question":"What is 6ES7317-7TK10-0AB0's listed CFC (Yes) on this component line?","answer":"CFC (Continuous Function Chart) is a programming language supported by this CPU, allowing graphical interconnection of function blocks. It is useful for process control and batch applications where signal flow is easier to visualize than ladder logic."},{"question":"Will 6ES7317-7TK10-0AB0 drop into a panel that was specified around 6ES7317-2EK14-0AB0 without rewiring?","answer":"No. The 7TK10 is an SFB type with FM 8 capability, while the 2EK14 is a standard CPU. The physical dimensions are the same (120 x 125 x 130 mm), but the backplane bus and firmware are different. The 7TK10 requires STEP 7 V5.5 SP2+ and the S7-Technology option package, and it does not support MPI or DPV1 like the 2EK14 does. Rewiring may not be needed if the I/O configuration matches, but the program and technology functions will need to be re-engineered."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7317-7TK10-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7317-7TK10-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}