{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7416-2FP07-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7416-2FP07-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7416-2FP07-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7416-2FP07-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-400 CPU 416-2 FP07, SFB type, 244-byte I/O, ATEX II 3G Ex nA IIC T4 Gc, cULus, CE, 25 x 290 x 219 mm.","salesMarkdown":"The Siemens 6ES7416-2FP07-0AB0 is an S7-400 CPU of the SFB (Siemens Function Block) type, designed for high-speed communication and deterministic control in medium-to-large automation systems. It supports CFC, FBD, LAD, SCL, STL, and GRAPH programming languages, giving the controls integrator flexibility to match the team's preferred IEC 61131-3 dialects. The FM (Function Module) capacity is limited by the number of slots and connections in the rack, not by a fixed count — so the practical limit depends on the backplane and power supply configuration you pair it with. This CPU handles 244 bytes each of process input and output images, which is right-sized for a mid-size line or machine cell without over-provisioning. For data exchange, it supports up to 8 RDREC and 8 WRREC operations per interface (SFB 52/53), with a total cap of 32 across all external interfaces. The same per-interface limit applies to SFC 59 and SFC 58. That matters when you're coordinating multiple PROFIBUS or PROFINET segments — plan your read/write load per interface, not just the aggregate. The CPU occupies a 25 mm slot width on the S7-400 rack, with a height of 290 mm and depth of 219 mm. That's a standard S7-400 footprint — it drops into any existing UR1/UR2 rack without re-drilling the gland plate or re-laying the backplane wiring. The isolated design helps reject common-mode noise from nearby drives or welding equipment. For PROFINET IO mode, a constraint: you can install up to 4 CP 443-1 communication processors in the central controller, but no mixed operation of different CP 443-1 types is allowed. If you're standardizing on one revision, that's fine — just don't mix old and new CPs in the same rack. ## Compliance and approvals — what ships with the part This CPU carries cULus approval for North American installations, CE marking for the European market, and ATEX II 3G Ex nA IIC T4 Gc certification for Zone 2 gas areas. That ATEX rating means it can be installed in a non-hazardous area with connections to Zone 2 classified locations — useful for chemical or oil & gas peripheral equipment. The GSD file for PROFIBUS configuration is available directly from Siemens support (ID 113652), so you can integrate it into any master class 1 tool without requesting documentation separately. ## Sourcing reality — what to expect It is not a current-production flagship, but it remains specified in many installed lines where the control architecture is frozen. If you are filling a BOM for a new panel, verify that your engineering team has the latest STEP 7 version that supports this FP07 firmware level.","metaTitle":"Siemens 6ES7416-2FP07-0AB0 S7-400 CPU, 25 mm, 0-60 °C, cULus","metaDescription":"Siemens S7-400 CPU 416-2 FP07 with SFB type, 244-byte I/O, ATEX II 3G, cULus, CE. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"Limited by number of slots and number of connections","CFC":"Yes","FBD":"Yes","LAD":"Yes","MPI":"Yes","SCL":"Yes","STL":"Yes","ATEX":"ATEX II 3G Ex nA IIC T4 Gc","DPV1":"Yes","Max.":"60 °C","Min.":"0 °C","Type":"SFB","Depth":"219 mm","GRAPH":"Yes","RDREC":"8; SFB 52; per interface, but not more than 32 across all external interfaces","WRREC":"8; SFB 53; per interface, but not more than 32 across all external interfaces","Width":"25 mm","cULus":"Yes","Height":"290 mm","Inputs":"244 byte","Number":"16","Preset":"120","RD_REC":"8; SFC 59; per interface","RS 485":"Yes","STEP 7":"Yes","WR_REC":"8; SFC 58; per interface","via CP":"4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode","CE mark":"Yes","CP, PtP":"CP 440: Limited by number of slots; CP 441: limited by number of connections","Forcing":"Yes","Outputs":"244 byte","Overall":"96","Present":"Yes","RDSYSST":"8; SFC 51","Routing":"Yes; with interface active","WR_PARM":"8; SFC 55; per interface","DPNRM_DG":"8; SFC 13; per interface","DP_TOPOL":"1; SFC 103; per interface","GSD file":"http://support.automation.siemens.com/WW/view/en/113652","Isolated":"Yes","PARM_MOD":"1; SFC 57; per interface","WR_DPARM":"2; SFC 56; per interface","As Client":"Yes","As Server":"Yes","HiGraph®":"Yes","MPI, max.":"200 ms","Retentive":"Yes","Supported":"Yes; Via CP and loadable FB","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Expandable":"No","Integrated":"0","Max. Cycle":"32 ms","Resolution":"1 ms","S7 routing":"Yes","Size, max.":"16 kbyte; Size of bit memory address area","via IM 467":"4","Command set":"see instruction list","FM approval":"Yes","Granularity":"1 h","KC approval":"Yes","Lower Limit":"10 ms","SYNC/FREEZE":"Yes","Single step":"Yes","Slots, max.":"244","UL approval":"Yes","Upper Limit":"9 990 s","CSA approval":"Yes","Equidistance":"Yes","Inputs, max.":"244 byte","Number, max.":"see instruction list","Preset, Max.":"600","Status block":"Yes; Up to 16 simultaneously","With Battery":"Yes; all data","in AS, slave":"Yes","to DP, slave":"Yes","to IF 964 DP":"No","Outputs, max.":"244 byte","Overall, Max.":"1 024","in AS, master":"Yes","to DP, master":"Yes","to MPI, slave":"Yes","Alarm 8-blocks":"Yes","Interface type":"PROFIBUS DP","Multicomputing":"Yes; 4 CPUs max. (with UR1 or UR2)","Nesting levels":"7","Per Slot, Max.":"128 byte","Program alarms":"Yes","Required Slots":"1","SCAN procedure":"Yes","Type of memory":"RAM","expandable RAM":"Yes; with Memory Card (RAM)","to MPI, master":"Yes","Can Be Read Out":"Yes","Inputs, default":"512 byte","Range of values":"SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours","Weight, approx.":"700 g","Without Battery":"No","connectable OPs":"95","lifecycle_stage":"mature","Adjustable, Max.":"32 kbyte","Block encryption":"Yes; With S7 block Privacy","Firmware version":"V7.0","Isochronous mode":"Yes","Of Which Central":"8 192","Outputs, default":"512 byte","Power loss, max.":"5.5 W","Power loss, typ.":"4.5 W","Rated value (DC)":"Power supply via system power supply","S7 communication":"Yes","Backup time, max.":"Dealt with in the module data manual with the secondary conditions and the factors of influence","Data length, max.":"1 452 bytes via CP 443-1 Adv.","PROFIBUS DP slave":"Yes","expandable FEPROM":"Yes; with Memory Card (FLASH)","Address area, max.":"32","Forcing, variables":"Inputs, outputs, bit memories, peripheral inputs, peripheral outputs","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"Yes","Per Priority Class":"24","Retentivity preset":"MB 0 to MB 15","Usable For Routing":"47","Data record routing":"Yes","Interfaces/bus type":"1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP","Number/Number range":"0 to 15","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Programming package":"STEP 7 V5.4 or higher with HSP 261","on Ethernet via NTP":"No; Via CP","Backup current, max.":"850 µA","Backup current, typ.":"180 µA; up to 40 °C","HW functional status":"01","ISO-on-TCP (RFC1006)":"Via CP 443-1 and loadable FB","In 100 Ms Grid, Max.":"128","In 500 Ms Grid, Max.":"512","Reserved For Routing":"0","Shortest Clock Pulse":"1 ms; 0.5 ms without use of SFC 126, 127","Via Interface Module":"0","expandable RAM, max.":"64 Mbyte","integrated RAM, max.":"1 Mbyte","Consistent Data, Max.":"244 byte","EAC (formerly Gost-R)":"Yes","In 1000 Ms Grid, Max.":"1 024","Integrated (For Data)":"4 Mbyte","Number of breakpoints":"16","Number of connections":"32","Number of startup OBs":"2; OB 100, 102","RCM (formerly C-TICK)":"Yes","Retentivity available":"Yes","S7 basic communication":"Yes","System functions (SFC)":"see instruction list","With 100 Ms Grid, Max.":"1","Number of entries, max.":"3 200","Status/control variable":"Yes; Up to 16 variable tables","Symbol-related messages":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"8 kbyte","expandable FEPROM, max.":"64 Mbyte","For Bit Operations, Typ.":"12.5 ns","Integrated (For Program)":"4 Mbyte","Number of DPV1 alarm OBs":"3; OB 55-57","Number of GD loops, max.":"16","Number of background OBs":"1; OB 90","Number of clock memories":"8; in 1 memory byte","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"8; OB 10-17","Process control messages":"Yes","Size of GD packets, max.":"54 byte","For Word Operations, Typ.":"12.5 ns","Global data communication":"No","Number of DP slaves, max.":"125","Number of delay alarm OBs":"4; OB 20-23","Number of variables, max.":"512","Of Which Consistent, Max.":"32 byte","PROFIBUS and Ethernet CPs":"14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller","Automatic Baud Rate Search":"No","Hardware clock (real-time)":"Yes","Number of RS 485 interfaces":"2; Combined MPI / PROFIBUS DP and PROFIBUS DP","Number of connections, max.":"32","Number of process alarm OBs":"8; OB 40-47","Process diagnostic messages":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","from interface 5 V DC, max.":"90 mA; At each DP interface","usable for OP communication":"95","usable for PG communication":"95","usable for S7 communication":"94","Adjustable For Routing, Max.":"0","Mixed mode IM + CP permitted":"No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode","Number of multicomputing OBs":"1; OB 60","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","User data per DP slave, max.":"244 byte","With 500, 1000 Ms Grid, Max.":"10","additional within an error OB":"2","reserved for OP communication":"1","reserved for PG communication":"1","reserved for S7 communication":"0","Number of connection resources":"32","Number of cyclic interrupt OBs":"9; OB 30-38 (shortest cycle that can be set = 500 µs)","Number of isochronous mode OBs":"4; OB 61-64","Number of expansion units, max.":"21","Number of synchronous error OBs":"2; OB 121, 122","from backplane bus 5 V DC, max.":"1.1 A","from backplane bus 5 V DC, typ.":"0.9 A","For Fixed Point Arithmetic, Typ.":"12.5 ns","Number of asynchronous error OBs":"9; OB 80-88","User data per address area, max.":"32 byte","from backplane bus 24 V DC, max.":"300 mA; 150 mA per DP interface","Number of subprocess images, max.":"15","usable for S7 basic communication":"94","Deviation per day (buffered), max.":"1.7 s; Power off","For Floating Point Arithmetic, Typ.":"25 ns","Number of connectable IM 460s, max.":"6","Number of connectable IM 463s, max.":"4; IM 463-2","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","CiR synchronization time, basic load":"100 ms","Deviation per day (unbuffered), max.":"8.6 s; For power On","Number of GD packets, receiver, max.":"32","Output current of the interface, max.":"150 mA","User data per isochronous slave, max.":"244 byte","adjustable for OP communication, max.":"0","adjustable for PG communication, max.":"0","adjustable for S7 communication, max.":"0","Number of GD packets, transmitter, max.":"16","Number of connectable IMs (total), max.":"6","Feeding of external backup voltage to CPU":"5 V DC to 15 V DC","Number of DP masters with isochronous mode":"2","simultaneously active Alarm-S blocks, max.":"1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks","CiR synchronization time, time per I/O byte":"10 µs","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"0","Size of GD packet (of which consistent), max.":"1 variable","User data per job (of which consistent), max.":"240 byte","Number of connectable OPs with message processing":"95; When using Alarm_S/SQ and Alarm_D/DQ","Direct data exchange (slave-to-slave communication)":"Yes","Number of connectable OPs without message processing":"95","Number of login stations for message functions, max.":"95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)","Retentive data area (incl. timers, counters, flags), max.":"Total working and load memory (with backup battery)","Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.":"64/64","Number of instances for alarm 8 and S7 communication blocks, max.":"4 000","Number of archives that can log on simultaneously (SFB 37 AR_SEND)":"32","number of simultaneously active system functions (SFC) / with DPSYC_FR":"2; SFC 11; per interface","number of simultaneously active system functions (SFC) / with D_ACT_DP":"8; SFC 12; per interface","Number of pluggable S5 modules (via adapter capsule in central device), max.":"6"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4f7c9d6e48628819cc051a8327f2f89.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=693839&mlfb=6ES7416-2FP07-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7416-2FP07-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What is the FM (Function Module) capacity of this CPU?","answer":"The FM capacity is limited by the number of slots and the number of connections in the rack, not by a fixed module count. The practical limit depends on the backplane and power supply you pair it with."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7416-2FP07-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7416-2FP07-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}