{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7416-3XL04-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7416-3XL04-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7416-3XL04-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7416-3XL04-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"********** Replacement part ********* SIMATIC S7-400, CPU 416-3 Central processing unit with: work memory 5.6 MB, (2.8 MB code, 2.8 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP, 3rd interface plug-in IFM module","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"Limited by number of slots and number of connections","CFC":"Yes","FBD":"Yes","LAD":"Yes","MPI":"Yes","SCL":"Yes","STL":"Yes","Type":"SFB","Depth":"219 mm","GRAPH":"Yes","RDREC":"8","WRREC":"8","Width":"50 mm","Height":"290 mm","Inputs":"244 byte","Number":"8","Preset":"120","RD_REC":"8","RS 485":"Yes","STEP 7":"Yes","WR_REC":"8","via CP":"10; CP 443-5 Extended","CP, LAN":"Limited by number of slots and number of connections","CP, PtP":"CP 440: Limited by number of slots; CP 441: limited by number of connections","Forcing":"Yes","Outputs":"244 byte","Overall":"64","Present":"Yes","RDSYSST":"8; 1 to 8","Routing":"Yes","WR_PARM":"8","DPNRM_DG":"8","DP_TOPOL":"1","GSD file":"http://www.siemens.com/profibus-gsd","Isolated":"Yes","PARM_MOD":"1","WR_DPARM":"2","As Client":"Yes","As Server":"Yes","HiGraph®":"Yes","Retentive":"Yes","Supported":"Yes; Via CP and loadable FB","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Expandable":"No","Integrated":"2","Max. Cycle":"32 ms","Resolution":"1 ms","S7 routing":"Yes","Size, max.":"16 kbyte","via IM 467":"4","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"10 ms","SYNC/FREEZE":"Yes","Single step":"Yes","Slots, max.":"244","Upper Limit":"9 990 s","Equidistance":"Yes","Inputs, max.":"244 byte","Number, max.":"see instruction list","Preset, Max.":"600","Status block":"Yes","With Battery":"Yes; all data","in AS, slave":"Yes","to DP, slave":"Yes","to IF 964 DP":"Yes; as Master or Slave","Outputs, max.":"244 byte","Overall, Max.":"1 024","in AS, master":"Yes","to DP, master":"Yes","to MPI, slave":"Yes","Alarm 8-blocks":"Yes","Interface type":"pluggable interface module (IF), technical data as for 2nd interface","Multicomputing":"Yes; 4 CPUs max. (with UR1 or UR2)","Nesting levels":"8","Per Slot, Max.":"128 byte","Program alarms":"Yes","Required Slots":"2","Type of memory":"RAM","expandable RAM":"Yes; with Memory Card (RAM)","to MPI, master":"Yes","Inputs, default":"512 byte","Range of values":"0 to 32767 hours","Weight, approx.":"1 070 g","Without Battery":"No","connectable OPs":"63 without message processing, 12 with message processing","lifecycle_stage":"mature","Adjustable, Max.":"32 kbyte","Firmware version":"V4.0","Isochronous mode":"Yes","Of Which Central":"8 192","Outputs, default":"512 byte","Power loss, typ.":"5 W","Rated value (DC)":"Power supply via system power supply","S7 communication":"Yes","Backup time, max.":"144 d","PROFIBUS DP slave":"Yes","expandable FEPROM":"Yes; with Memory Card (FLASH)","Address area, max.":"32","Forcing, variables":"Inputs/outputs, bit memories, distributed I/Os","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"Yes","Per Priority Class":"24","Retentivity preset":"MB 0 to MB 15","Number/Number range":"0 to 7","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Programming package":"STEP 7 V5.2 SP1 HF3 or higher with HW update","Backup current, max.":"1 530 µA","Backup current, typ.":"550 µA","In 100 Ms Grid, Max.":"128","In 500 Ms Grid, Max.":"512","Shortest Clock Pulse":"1 ms","Via Interface Module":"1; IF 964-DP","expandable RAM, max.":"64 Mbyte","integrated RAM, max.":"256 kbyte","Consistent Data, Max.":"244 byte","In 1000 Ms Grid, Max.":"1 024","Integrated (For Data)":"2 800 kbyte","Number of breakpoints":"4","Number of connections":"44","Retentivity available":"Yes; MB 0 to MB 16383","S7 basic communication":"Yes","System functions (SFC)":"see instruction list","With 100 Ms Grid, Max.":"1","Number of entries, max.":"3 200","Status/control variable":"Yes","Symbol-related messages":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"8 kbyte","expandable FEPROM, max.":"64 Mbyte","For Bit Operations, Typ.":"0.04 µs","Integrated (For Program)":"2 800 kbyte","Number of GD loops, max.":"16","Number of clock memories":"8; 1 memory byte","Number of time alarm OBs":"8","Process control messages":"Yes","Size of GD packets, max.":"64 byte","For Word Operations, Typ.":"0.04 µs","Global data communication":"Yes","Number of DP slaves, max.":"125","Number of delay alarm OBs":"4","Number of variables, max.":"512","Of Which Consistent, Max.":"32 byte","PROFIBUS and Ethernet CPs":"14; incl. CP 443-5 Ext. and IM 467","Plug-in interface modules":"IF 964-DP","Hardware clock (real-time)":"Yes","Number of connections, max.":"32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1","Number of process alarm OBs":"8","Mixed mode IM + CP permitted":"No; IM 467 cannot be used with CP 443-5 Ext., IM 467 cannot be used with CP 443-1 EX40 in PROFINET IO mode","Number of multicomputing OBs":"1","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","With 500, 1000 Ms Grid, Max.":"10","additional within an error OB":"2","reserved for OP communication":"1","reserved for PG communication":"1","Number of connection resources":"32","Number of cyclic interrupt OBs":"9","Number of expansion units, max.":"21; of which 6 ER with K-bus","from backplane bus 5 V DC, max.":"1.4 A","from backplane bus 5 V DC, typ.":"1.2 A","For Fixed Point Arithmetic, Typ.":"0.04 µs","User data per address area, max.":"32 byte","from backplane bus 24 V DC, max.":"Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface","Number of subprocess images, max.":"15","Deviation per day (buffered), max.":"1.7 s; Power on","For Floating Point Arithmetic, Typ.":"0.12 µs","Number of connectable IM 460s, max.":"6","Number of connectable IM 463s, max.":"4; IM 463-2","Activation/deactivation of DP slaves":"Yes","CiR synchronization time, basic load":"100 ms","Deviation per day (unbuffered), max.":"8.6 s; Power off","Number of GD packets, receiver, max.":"32","Output current of the interface, max.":"150 mA","User data per isochronous slave, max.":"244 byte","Number of GD packets, transmitter, max.":"16","Number of connectable IMs (total), max.":"6","Feeding of external backup voltage to CPU":"5 V DC to 15 V DC","simultaneously active Alarm-S blocks, max.":"200; ALARM_S/SQ blocks or ALARM_D/DQ blocks","CiR synchronization time, time per I/O byte":"40 µs","User program protection/password protection":"Yes","Size of GD packet (of which consistent), max.":"1 variable","User data per job (of which consistent), max.":"240 byte","Number of connectable OPs with message processing":"12","Direct data exchange (slave-to-slave communication)":"Yes","Number of connectable OPs without message processing":"63","Number of login stations for message functions, max.":"12","Retentive data area (incl. timers, counters, flags), max.":"Total working and load memory (with backup battery)","Number of instances for alarm 8 and S7 communication blocks, max.":"1 800","Number of archives that can log on simultaneously (SFB 37 AR_SEND)":"32","number of simultaneously active system functions (SFC) / with DPSYC_FR":"2","number of simultaneously active system functions (SFC) / with D_ACT_DP":"4","Number of pluggable S5 modules (via adapter capsule in central device), max.":"6"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,601.38","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/106e1fa288e9cd586c495c84907df505.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=19586&mlfb=6ES7416-3XL04-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7416-3XL04-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7416-3XL04-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7416-3XL04-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}