{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7417-4HL04-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7417-4HL04-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7417-4HL04-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7417-4HL04-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"********** Replacement part ********* SIMATIC S7-400H, CPU 417H Central processing unit for S7-400H 4 interfaces: 1 MPI/DP, 1 DP and 2 for sync modules 20 MB memory (10 MB data/10 MB program)","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"64; Limited by number of slots and number of connections","CFC":"Yes","FBD":"Yes","LAD":"Yes","MPI":"Yes; Default setting","SCL":"Yes","STL":"Yes","Type":"SFB","Depth":"219 mm","GRAPH":"Yes","Width":"50 mm","Height":"290 mm","Inputs":"8 192","Number":"8","Preset":"Z 0 to Z 7","RS 485":"Yes","STEP 7":"Yes; V5.0 SP2","via CP":"10","CP, LAN":"64; Limited by number of slots and number of connections","CP, PtP":"64; Limited by number of slots and number of connections","Outputs":"8 192","Overall":"64","Present":"Yes","Isolated":"Yes","As Client":"Yes","As Server":"Yes","HiGraph®":"Yes","Supported":"Yes; Via CP and loadable FB","Adjustable":"Yes","Expandable":"No","Integrated":"2","Size, max.":"16 kbyte","via IM 467":"0","Lower Limit":"10 ms","SYNC/FREEZE":"No","Upper Limit":"9 990 s","Equidistance":"No","Inputs, max.":"244 byte","Number, max.":"see instruction list","With Battery":"Yes; all data","Outputs, max.":"244 byte","Interface type":"PROFIBUS DP","Multicomputing":"No","Required Slots":"2","Type of memory":"RAM","expandable RAM":"Yes; with Memory Card (RAM)","Inputs, default":"1 024 byte","Weight, approx.":"1 070 g","Without Battery":"No","lifecycle_stage":"mature","Of Which Central":"8 192","Outputs, default":"1 024 byte","Power loss, typ.":"6 W","Rated value (DC)":"Power supply via system power supply","S7 communication":"No","PROFIBUS DP slave":"No","expandable FEPROM":"Yes; with Memory Card (FLASH)","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"Yes","Per Priority Class":"24","Retentivity preset":"MB 0 to MB 15","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Backup current, max.":"1 810 µA","Backup current, typ.":"600 µA","Reserved For Routing":"0","Via Interface Module":"0","expandable RAM, max.":"64 Mbyte","integrated RAM, max.":"256 kbyte","Number of connections":"44","Retentivity available":"Yes; MB 0 to MB 16383","S7 basic communication":"No","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"Dependent on CP","expandable FEPROM, max.":"64 Mbyte","For Bit Operations, Typ.":"0.03 µs","For Word Operations, Typ.":"0.03 µs","Global data communication":"No","Number of DP slaves, max.":"125; Number of slots, max. 2 048","Point-to-point connection":"No","Hardware clock (real-time)":"Yes","Number of connections, max.":"32","S7 communication, as client":"No","S7 communication, as server":"No","Adjustable For Routing, Max.":"0","Mixed mode IM + CP permitted":"No; IM 467 cannot be used jointly with CP 443-5 Ext.","Retentive And Synchronizable":"Yes","additional within an error OB":"2","reserved for OP communication":"1","reserved for PG communication":"1","Number of expansion units, max.":"21","from backplane bus 5 V DC, max.":"1.7 A","For Fixed Point Arithmetic, Typ.":"0.03 µs","Number of subprocess images, max.":"8","For Floating Point Arithmetic, Typ.":"0.09 µs","Number of connectable IM 460s, max.":"6","Number of connectable IM 463s, max.":"6; IM 463-2","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"No","adjustable for OP communication, max.":"0","adjustable for PG communication, max.":"0","Number of connectable IMs (total), max.":"6","Feeding of external backup voltage to CPU":"5 V DC to 15 V DC","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"0","Direct data exchange (slave-to-slave communication)":"No","Number of login stations for message functions, max.":"16"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,526.28","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/85955fb265602776d2fe9ddebef35c38.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=507753&mlfb=6ES7417-4HL04-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7417-4HL04-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7417-4HL04-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7417-4HL04-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}