{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7417-4XT05-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7417-4XT05-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7417-4XT05-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7417-4XT05-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"********** Replacement part ********* SIMATIC S7-400, CPU 417-4 Central processing unit with: work memory 30 MB, (15 MB code; 15 MB data) 1st interface MPI 12 Mbit/s; 2nd interface PROFIBUS DP, 3rd/4th interface plug-in IFM module","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"Limited by number of slots and number of connections","CFC":"Yes","FBD":"Yes","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","DPV0":"Yes","DPV1":"No","Type":"SFB","Depth":"219 mm","GRAPH":"Yes","RDREC":"8","WRREC":"8","Width":"50 mm","Height":"290 mm","Inputs":"244 byte","Number":"16","Preset":"120","RD_REC":"8","RS 485":"Yes","STEP 7":"Yes","WR_REC":"8","via CP":"4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller","CP, PtP":"CP 440: Limited by number of slots; CP 441: limited by number of connections","Forcing":"Yes","Outputs":"244 byte","Overall":"64","Present":"Yes","RDSYSST":"8","Routing":"Yes; with interface active","WR_PARM":"8","DPNRM_DG":"8","DP_TOPOL":"1","GSD file":"http://support.automation.siemens.com/WW/view/en/113652","Isolated":"Yes","PARM_MOD":"1","WR_DPARM":"2","As Client":"Yes","As Server":"Yes","HiGraph®":"Yes","MPI, max.":"200 ms","Retentive":"Yes","Supported":"Yes; Via CP and loadable FB","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Expandable":"No","Integrated":"0","Max. Cycle":"32 ms","Resolution":"1 ms","S7 routing":"Yes","Size, max.":"16 kbyte; Size of bit memory address area","via IM 467":"4","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"10 ms","SYNC/FREEZE":"Yes","Single step":"Yes","Slots, max.":"244","Upper Limit":"9 990 s","Equidistance":"Yes","Inputs, max.":"244 byte","Number, max.":"see instruction list","Preset, Max.":"1 200","Status block":"Yes; Up to 2 simultaneously","With Battery":"Yes; all data","in AS, slave":"Yes","to DP, slave":"Yes","to IF 964 DP":"Yes","Outputs, max.":"244 byte","Overall, Max.":"1 024","in AS, master":"Yes","to DP, master":"Yes","to MPI, slave":"Yes","Alarm 8-blocks":"Yes","Interface type":"pluggable interface module (IF), technical data as for 2nd interface","Multicomputing":"Yes; 4 CPUs max. (with UR1 or UR2)","Nesting levels":"7","Per Slot, Max.":"128 byte","Program alarms":"Yes","Required Slots":"2","SCAN procedure":"Yes","Type of memory":"RAM","expandable RAM":"Yes; with Memory Card (RAM)","to MPI, master":"Yes","Inputs, default":"1 024 byte","Range of values":"SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours","Weight, approx.":"0.9 kg","Without Battery":"No","connectable OPs":"63","lifecycle_stage":"mature","Adjustable, Max.":"64 kbyte","Firmware version":"V5.3","Isochronous mode":"Yes","Of Which Central":"8 192","Outputs, default":"1 024 byte","Power loss, max.":"8 W","Power loss, typ.":"7.5 W","Rated value (DC)":"Power supply via system power supply","S7 communication":"Yes","Backup time, max.":"See reference manual, module data, Chapter 3.3","Data length, max.":"1 452 bytes via CP 443-1 Adv.","Optical interface":"No","PROFIBUS DP slave":"Yes","expandable FEPROM":"Yes; with Memory Card (FLASH)","Address area, max.":"32","Forcing, variables":"Inputs, outputs, bit memories, peripheral inputs, peripheral outputs","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"Yes","Per Priority Class":"24","Retentivity preset":"MB 0 to MB 15","Data record routing":"Yes","Interfaces/bus type":"1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)","Number/Number range":"0 to 15","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Programming package":"STEP 7 V5.3 SP2 or higher with HW update","on Ethernet via NTP":"No; Via CP","Backup current, max.":"750 µA","Backup current, typ.":"225 µA; up to 40 °C","HW functional status":"04","ISO-on-TCP (RFC1006)":"Via CP 443-1 and loadable FB","In 100 Ms Grid, Max.":"128","In 500 Ms Grid, Max.":"512","Reserved For Routing":"0","Shortest Clock Pulse":"1 ms; 0.5 ms without use of SFC 126, 127","Via Interface Module":"2","expandable RAM, max.":"64 Mbyte","integrated RAM, max.":"1 Mbyte","Consistent Data, Max.":"244 byte","In 1000 Ms Grid, Max.":"1 024","Integrated (For Data)":"15 Mbyte","Number of breakpoints":"4","Number of connections":"32","Number of startup OBs":"3; OB 100-102","Retentivity available":"Yes","S7 basic communication":"No","System functions (SFC)":"see instruction list","With 100 Ms Grid, Max.":"1","Integrated power supply":"No","Number of entries, max.":"3 200","Status/control variable":"Yes; Up to 16 variable tables","Symbol-related messages":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"8 kbyte","expandable FEPROM, max.":"64 Mbyte","For Bit Operations, Typ.":"18 ns","Integrated (For Program)":"15 Mbyte","Number of DPV1 alarm OBs":"3; OB 55-57","Number of GD loops, max.":"16","Number of background OBs":"1; OB 90","Number of clock memories":"8; in 1 memory byte","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"8; OB 10-17","Process control messages":"Yes","Size of GD packets, max.":"54 byte","For Word Operations, Typ.":"18 ns","Global data communication":"No","Number of DP slaves, max.":"125","Number of delay alarm OBs":"4; OB 20-23","Number of variables, max.":"512","Of Which Consistent, Max.":"32 byte","PROFIBUS and Ethernet CPs":"14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum","Plug-in interface modules":"IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)","Automatic Baud Rate Search":"No","Hardware clock (real-time)":"Yes","Number of other interfaces":"0","Number of RS 485 interfaces":"2","Number of connections, max.":"32","Number of process alarm OBs":"8; OB 40-47","Process diagnostic messages":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","from interface 5 V DC, max.":"90 mA; At each DP interface","Adjustable For Routing, Max.":"0","Mixed mode IM + CP permitted":"No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)","Number of multicomputing OBs":"1; OB 60","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","User data per DP slave, max.":"244 byte","With 500, 1000 Ms Grid, Max.":"10","additional within an error OB":"2","reserved for OP communication":"1","reserved for PG communication":"1","reserved for S7 communication":"0","Number of connection resources":"32","Number of cyclic interrupt OBs":"9; OB 30-38 (shortest cycle that can be set = 500 µs)","Number of isochronous mode OBs":"4; OB 61-64","Number of expansion units, max.":"21","Number of synchronous error OBs":"2; OB 121, 122","from backplane bus 5 V DC, max.":"1.8 A","from backplane bus 5 V DC, typ.":"1.5 A","For Fixed Point Arithmetic, Typ.":"18 ns","Number of asynchronous error OBs":"9; OB 80-88","User data per address area, max.":"32 byte","from backplane bus 24 V DC, max.":"600 mA; 150 mA per DP interface","Number of subprocess images, max.":"15","Deviation per day (buffered), max.":"1.7 s; Power off","For Floating Point Arithmetic, Typ.":"54 ns","Number of connectable IM 460s, max.":"6","Number of connectable IM 463s, max.":"4; IM 463-2","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","CiR synchronization time, basic load":"60 ms","Deviation per day (unbuffered), max.":"8.6 s; For power On","Number of GD packets, receiver, max.":"32","Output current of the interface, max.":"150 mA","User data per isochronous slave, max.":"244 byte","adjustable for OP communication, max.":"0","adjustable for PG communication, max.":"0","adjustable for S7 communication, max.":"0","Number of GD packets, transmitter, max.":"16","Number of connectable IMs (total), max.":"6","Automatic Detection Of Transmission Rate":"No","Feeding of external backup voltage to CPU":"5 V DC to 15 V DC","Limit class A, for use in industrial areas":"Yes","Number of DP masters with isochronous mode":"4","simultaneously active Alarm-S blocks, max.":"1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks","CiR synchronization time, time per I/O byte":"7 µs","Limit class B, for use in residential areas":"No","User program protection/password protection":"Yes","adjustable for S7 basic communication, max.":"0","Size of GD packet (of which consistent), max.":"1 variable","User data per job (of which consistent), max.":"240 byte","Number of connectable OPs with message processing":"63; When using alarm_S and alarm_D","Direct data exchange (slave-to-slave communication)":"No","Number of connectable OPs without message processing":"63","Number of login stations for message functions, max.":"63; Max. 63 with ALARM_S and ALARM_D (OPs); max. 12 with ALARM_8 and ALARM_P (e.g. WinCC)","Retentive data area (incl. timers, counters, flags), max.":"Total working and load memory (with backup battery)","Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.":"64/64","Number of instances for alarm 8 and S7 communication blocks, max.":"10 000","Number of archives that can log on simultaneously (SFB 37 AR_SEND)":"64","number of simultaneously active system functions (SFC) / with DPSYC_FR":"2","number of simultaneously active system functions (SFC) / with D_ACT_DP":"8","Number of pluggable S5 modules (via adapter capsule in central device), max.":"6"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,943.60 – $12,169.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/227fe47ddc79c8c0ea85aecafcc36ce5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=230143&mlfb=6ES7417-4XT05-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7417-4XT05-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7417-4XT05-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7417-4XT05-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}