{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7510-1DJ00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7510-1DJ00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7510-1DJ00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7510-1DJ00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1500 CPU 1510-1 PN, 6ES7510-1DJ00-0AB0, MRP redundancy manager, integrated PID temperature control, 32 kB I/O process image, MODBUS TCP.","salesMarkdown":"## CPU 1510-1 PN: S7-1500 mid-range controller with redundancy and built-in PID The 6ES7510-1DJ00-0AB0 supports PROFINET with MRP as redundancy manager (ring up to 50 devices) and MRPD with IRT. Integrated PID controllers handle temperature and valve positioning. The process image accommodates 32 kbytes each for inputs and outputs, all presented in the process image—no external mapping required. ## Communication and protocol support Ethernet interface runs at 100 Mbps and supports MODBUS TCP alongside PROFINET. Default HTTP and HTTPS server allow standard and user-defined pages. No DHCP client; configure IP statically or via DCP. SNMP, LLDP, and UDP are available for network diagnostics. Programming can be done in LAD, FBD, STL, SCL, and GRAPH—all supported. S7 routing and forcing are enabled. The hardware clock is present. Width 100 mm, height 117 mm, depth 75 mm. Mounts on standard DIN rail or panel.","metaTitle":"Siemens 6ES7510-1DJ00-0AB0 CPU 1510-1 PN, MRP, PID","metaDescription":"Siemens SIMATIC S7-1500 CPU 1510-1 PN. Supports MRP redundancy manager, integrated PID temperature control, 32 kB process image, MODBUS TCP. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"DCP":"Yes","FBD":"Yes","I2t":"0.14 A²·s","IRT":"Yes","LAD":"Yes","MRP":"Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"Yes; Standard and user-defined pages","LLDP":"Yes","MRPD":"Yes; Requirement: IRT","SNMP":"Yes","Type":"Hardware clock","Depth":"75 mm","GRAPH":"Yes","HTTPS":"Yes; Standard and user-defined pages","Width":"100 mm","title":"6ES7510-1DJ00-0AB0","Height":"117 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"16","RS 485":"Yes; Via CM DP module","TCP/IP":"Yes","Via CM":"0","Forcing":"Yes","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","PID-Temp":"Yes; PID controller with integrated optimization for temperature","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"Yes","Size, max.":"16 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","Via Dataset":"Yes","description":"***Spare part*** SIMATIC DP, CPU 1510SP-1 PN for ET 200SP, Central processing unit with Work memory 100 KB for program and 750 KB for data, 1st interface, PROFINET IRT with 3-port switch, 72 ns bit performance, SIMATIC Memory Card required, BusAdapter required for Port 1 and 2","Autocrossing":"Yes","Equidistance":"No","Number range":"0 ... 65 535","RUN/STOP LED":"Yes","Status block":"Yes; Up to 8 simultaneously (in total across all ES clients)","in AS, slave":"Yes","to DP, slave":"Yes; Via CM DP module","Shared device":"Yes","in AS, master":"Yes","to DP, master":"Yes; Via CM DP module","Motion Control":"Yes","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"1","Weight, approx.":"310 g","lifecycle_stage":"current","Block protection":"Yes","Firmware version":"V1.8","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"only via 1st interface (X1)","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.6 W","RJ 45 (Ethernet)":"Yes; X1","Rated value (DC)":"24 V","Data length, max.":"1 472 byte","Integrated Switch":"Yes","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","PROFIBUS DP slave":"Yes","Forcing, variables":"Peripheral inputs/outputs","High-speed counter":"Yes","PROFIBUS DP master":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24","Retentivity preset":"No","Data record routing":"Yes","PG/OP communication":"Yes","Prioritized startup":"Yes; Max. 32 PROFINET devices","on Ethernet via NTP":"Yes","Direct data exchange":"Yes; Requirement: IRT and isochronous mode (MRPD optional)","HW functional status":"FS04","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"4.7 A; Rated value","Mode selector switch":"1","Number of IO modules":"1 024; max. number of modules / submodules","Number of axes, max.":"3; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool","BusAdapter (PROFINET)":"Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC","Integrated (For Data)":"750 kbyte","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes","SIL acc. to IEC 61508":"No","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"64; CPU + 64 modules + server module (mounting width max. 1 m)","Of Which In Line, Max.":"64","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"1 000","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"See online help (S7 communication, user data size)","For Bit Operations, Typ.":"72 ns","Integrated (For Program)":"100 kbyte","Number of DPV1 alarm OBs":"3","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of program alarms":"300","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"500","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"86 ns","Number of DP slaves, max.":"125","Number of delay alarm OBs":"20","Number of variables, max.":"200","Number of S7 routing paths":"16","Number of elements (total)":"2 000; Blocks (OB, FB, FC, DB) and UDTs","Number of connections, max.":"64","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Number of PROFIBUS interfaces":"1; Via CM DP module","Number of PROFINET interfaces":"1","Number of configurable Traces":"4; Up to 512 KB of data per trace are possible","Address space per module, max.":"32 byte; For input and output data respectively","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Address space per station, max.":"1 280 byte; for central inputs and outputs; depending on configuration","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"115 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"20","Number of positioning axes, max.":"6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"0.6 A","Infeed power to the backplane bus":"8.75 W","Number of external encoders, max.":"6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool","Number of subprocess images, max.":"32","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"461 ns","Joint commission (Team Engineering)":"Yes; Parallel online access possible for up to 3 engineering systems","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Activation/deactivation of DP slaves":"Yes","Number of stations in the ring, max.":"50","Number of speed-controlled axes, max.":"6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"64; In total, up to 189 distributed I/O devices can be connected via PROFIBUS or PROFINET","Number of alarms for system diagnostics":"100","Number of slots for SIMATIC memory card":"1","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"5 ms","Monitoring of the supply voltage (PWR-LED)":"Yes","Number of technology synchronous alarm OBs":"2","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000","Number of connectable IO Devices for RT, max.":"64","Number of connections reserved for ES/HMI/web":"10","Number of alarms for motion technology objects":"80","Number of connections via integrated interfaces":"64","Several Passive Connections Per Port, Supported":"Yes","Number of IO Controllers with shared device, max.":"4","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Number of login stations for message functions, max.":"32","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1 Update 4","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8; in total across all interfaces"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$873.25","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce9ac6d45726561f85da09d9c983a054.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=93916&mlfb=6ES7510-1DJ00-0AB0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7510-1DJ00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7510-1DJ00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}