{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7510-1SJ00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7510-1SJ00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7510-1SJ00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7510-1SJ00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 failsafe CPU, 6ES7510-1SJ00-0AB0, compact 100 mm, PROFINET, FBD/LAD failsafe, MRP, PID control.","salesMarkdown":"## Compact failsafe CPU with integrated PROFINET The Siemens 6ES7510-1SJ00-0AB0 is a compact failsafe CPU, 100 mm wide, with integrated PROFINET and support for FBD and LAD failsafe programming. It includes PROFIsafe for safety communication over the network, and handles up to 32 kbyte of process image for both inputs and outputs. Equipped with MRP redundancy manager/client capability (up to 50 devices in a ring) and MRPD requiring IRT, this CPU fits into high-availability topologies. On-board PID control for temperature and valves simplifies loop applications without extra modules. DIN-rail mount, 100 mm wide fits standard enclosure. Depth 75 mm leaves room for front connectors and cable bend radius. Terminal access on the front; leave 50 mm clearance below for PROFINET patch cables. Spring-clamp screwless connections on the power supply and integrated I/O—strip 10 mm. PROFINET ports are on the left side; use standard RJ45 cables. For MRP rings, connect port 1 and port 2 to neighbours. No additional PROFINET switch needed for small rings.","metaTitle":"Siemens 6ES7510-1SJ00-0AB0 failsafe CPU, PROFINET, compact","metaDescription":"Compact failsafe CPU with 32KB process image, MRP, PID control. Sourced to order. S7-1500 series, 100x117x75mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"DCP":"Yes","FBD":"Yes; incl. failsafe","I2t":"0.14 A²·s","IRT":"Yes","LAD":"Yes; incl. failsafe","MRP":"Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"Yes; Standard and user-defined pages","LLDP":"Yes","MRPD":"Yes; Requirement: IRT","SNMP":"Yes","Type":"Hardware clock","Depth":"75 mm","GRAPH":"Yes","HTTPS":"Yes; Standard and user-defined pages","Width":"100 mm","title":"6ES7510-1SJ00-0AB0","Height":"117 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"16","RS 485":"Yes; Via CM DP module","TCP/IP":"Yes","Via CM":"0","Forcing":"Yes","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","PID-Temp":"Yes; PID controller with integrated optimization for temperature","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","PROFIsafe":"Yes","Supported":"Yes","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"Yes","Size, max.":"16 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","Via Dataset":"Yes","description":"***Spare part*** SIMATIC DP, CPU 1510SP F-1 PN for ET 200SP, Central processing unit with Work memory 150 KB for program and 750 KB for data, 1st interface, PROFINET IRT with 3-port switch, 72 ns bit performance, SIMATIC Memory Card required, BusAdapter required for Port 1 and 2","Autocrossing":"Yes","Equidistance":"No","Number range":"1 ... 65 535","RUN/STOP LED":"Yes","Status block":"Yes; Up to 8 simultaneously (in total across all ES clients)","in AS, slave":"Yes","to DP, slave":"Yes; Via CM DP module","Shared device":"Yes","in AS, master":"Yes","to DP, master":"Yes; Via CM DP module","Motion Control":"Yes","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"1","Weight, approx.":"310 g","lifecycle_stage":"current","Block protection":"Yes","Firmware version":"V1.7","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"only via 1st interface (X1)","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.6 W","RJ 45 (Ethernet)":"Yes; 1. integr. + 2. via BusAdapter BA 2x RJ45","Rated value (DC)":"24 V","Data length, max.":"1 472 byte","Integrated Switch":"Yes","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","PROFIBUS DP slave":"Yes","Forcing, variables":"Inputs, outputs","High-speed counter":"Yes","PROFIBUS DP master":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24; Up to 8 possible for F-blocks","Retentivity preset":"No","Data record routing":"Yes","PG/OP communication":"Yes","Prioritized startup":"Yes; Max. 32 PROFINET devices","on Ethernet via NTP":"Yes","Direct data exchange":"Yes; Requirement: IRT and isochronous mode (MRPD optional)","HW functional status":"FS01","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"4.7 A; Rated value","Mode selector switch":"1","Number of IO modules":"1 024; max. number of modules / submodules","Number of axes, max.":"3; Max. number of synchronous axes (requirement: there must be no other motion technology objects created)","Integrated (For Data)":"750 kbyte","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes","SIL acc. to IEC 61508":"SIL 3","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"64; CPU + 64 modules + server module (mounting width max. 1 m)","Of Which In Line, Max.":"64","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"1 000","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"See online help (S7 communication, user data size)","For Bit Operations, Typ.":"72 ns","Integrated (For Program)":"150 kbyte","Number of DPV1 alarm OBs":"3","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of program alarms":"300","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"500","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"86 ns","Number of DP slaves, max.":"125","Number of delay alarm OBs":"20","Number of variables, max.":"200","Number of S7 routing paths":"16","Number of elements (total)":"2 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements","Number of connections, max.":"64","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Number of PROFIBUS interfaces":"1; Via CM DP module","Number of PROFINET interfaces":"1","Number of configurable Traces":"4; Up to 512 KB of data per trace are possible","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20; With Failsafe, two RTGs with one \"Cyclic interrupt OB\" or one \"Free cycle OB\" (F-OB) each are possible","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"115 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"2","Number of positioning axes, max.":"6; Max. number of positioning axes (requirement: there must be no other motion technology objects created)","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"0.6 A","Infeed power to the backplane bus":"8.75 W","Number of external encoders, max.":"6; Max. number of external encoders (requirement: there must be no other motion technology objects created)","Number of subprocess images, max.":"32","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes; Specific write protection both for Standard and for Failsafe","For Floating Point Arithmetic, Typ.":"461 ns","Joint commission (Team Engineering)":"Yes; Parallel online access possible for up to 3 engineering systems","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Activation/deactivation of DP slaves":"Yes","Number of stations in the ring, max.":"50","Number of speed-controlled axes, max.":"6; Max. number of speed-controlled axes (requirement: there must be no other motion technology objects created)","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"64; In total, up to 189 distributed I/O devices can be connected via PROFIBUS or PROFINET","Number of alarms for system diagnostics":"100","Number of slots for SIMATIC memory card":"1","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"5 ms","Monitoring of the supply voltage (PWR-LED)":"Yes","Number of technology synchronous alarm OBs":"2","Performance level according to ISO 13849-1":"PLe","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000","Number of connectable IO Devices for RT, max.":"64","Number of connections reserved for ES/HMI/web":"10","Number of alarms for motion technology objects":"80","Low demand mode: PFDavg in accordance with SIL3":"< 2.00E-05","Number of connections via integrated interfaces":"64","Several Passive Connections Per Port, Supported":"Yes","Number of IO Controllers with shared device, max.":"4","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Number of login stations for message functions, max.":"32","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","High demand/continuous mode: PFH in accordance with SIL3":"< 1.00E-09","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8; in total across all interfaces"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$665.48","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce9ac6d45726561f85da09d9c983a054.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=552739&mlfb=6ES7510-1SJ00-0AB0"},"ai":{"faq":[{"question":"What does the failsafe capability mean for this CPU?","answer":"The CPU supports FBD and LAD programming with failsafe extensions (FBD incl. failsafe, LAD incl. failsafe) and PROFIsafe over PROFINET. You can write safety logic directly without an external fail-safe module, keeping the design compact."},{"question":"Does it support MRP and IRT?","answer":"Yes, MRP as redundancy manager and/or client with up to 50 devices per ring. MRPD is supported but requires IRT."},{"question":"What programming languages are available?","answer":"All standard S7-1500 languages: LAD, FBD, SCL, STL, GRAPH. FBD and LAD include failsafe variants."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7510-1SJ00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7510-1SJ00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}