{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7513-1RL00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7513-1RL00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7513-1RL00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7513-1RL00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6ES7513-1RL00-0AB0. Full specifications and sourcing options are below.","salesMarkdown":"## Overview The 6ES7513-1RL00-0AB0 is a Siemens Unclassified module with DNS support enabled, two ports, and MRP Automanager per IEC 62439-2 Edition 2.0 for network redundancy. It communicates via Modbus TCP and IPv4 at 100 Mbps, drawing 5.7 W, and measures 35 mm wide, 147 mm high, 129 mm deep at 430 g. This module acts as a network interface with MRP Automanager capability, enabling ring redundancy per IEC 62439-2 Edition 2.0 — critical for high-availability industrial networks where a single cable break must not drop communication. The two ports support Modbus TCP and IPv4 at 100 Mbps, with LLDP for topology discovery and SNMP for network management, plus UDP for multicast or datagram traffic. ## Applications Typical deployment is in industrial Ethernet rings where MRP redundancy is specified — for example, on machine cells, conveyor systems, or process skids that require deterministic failover under 200 ms. The Modbus TCP and IPv4 stack fits into mixed-protocol environments where legacy Modbus devices coexist with modern IP-based controllers. Within the Siemens portfolio this module sits in the Unclassified category, but its feature set — MRP Automanager, Modbus TCP, IPv4, LLDP, SNMP — aligns it with network interface modules for S7-1500 or ET 200SP systems that need redundant ring topology. It is specified by controls integrators who require a compact, DIN-rail-mounted device with both MRP redundancy and Modbus TCP gateway capability in a single unit. The evidence does not list an official lifecycle status for the 6ES7513-1RL00-0AB0.","metaTitle":"Siemens 6ES7513-1RL00-0AB0 Unclassified Module, DNS Yes, 2 Ports, MRP, Modbus TC","metaDescription":"Siemens 6ES7513-1RL00-0AB0 Unclassified module: DNS yes, 2 ports, MRP Automanager per IEC 62439-2, Modbus TCP, IPv4, 100 Mbps, 5.7 W, 430 g.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"CFC":"No","DCP":"Yes","DNS":"Yes","FBD":"Yes","I2t":"0.02 A²·s","IRT":"No","LAD":"Yes","MRP":"Yes; MRP Automanager according to IEC 62439-2 Edition 2.0","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"No","LLDP":"Yes","MRPD":"No","Max.":"70 °C","Min.":"-40 °C","SNMP":"Yes","Type":"Hardware clock","Depth":"129 mm","GRAPH":"Yes","HTTPS":"No","Width":"35 mm","Height":"147 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"16","TCP/IP":"Yes","Forcing":"Yes","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","I&M data":"Yes; I&M0 to I&M3","PID-Temp":"Yes; PID controller with integrated optimization for temperature","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"No","Size, max.":"16 kbyte","Web server":"No","Backup time":"6 wk; At 40 °C ambient temperature, typically","IP protocol":"Yes; IPv4","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","Autocrossing":"Yes","Equidistance":"No","Number range":"0 ... 65 535","RUN/STOP LED":"Yes","Status block":"Yes; up to 8 simultaneously","OPC UA Client":"No","OPC UA Server":"No","UDP multicast":"Yes; Max. 5 multicast circuits","Motion Control":"No","Number of keys":"6","Program alarms":"Yes","Autonegotiation":"Yes","Copy protection":"No","Inputs (volume)":"8 kbyte","Number of ports":"2","Weight, approx.":"430 g","lifecycle_stage":"current","Block protection":"Yes","Firmware version":"V2.9","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"Yes","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.7 W","RJ 45 (Ethernet)":"Yes; X1","Rated value (DC)":"24 V","Data length, max.":"2 kbyte; 1 472 bytes for UDP broadcast","Integrated Switch":"Yes","Forcing, variables":"Peripheral inputs/outputs","High-speed counter":"No","PROFINET IO Device":"No","Per Priority Class":"24","Retentivity preset":"No","PG/OP communication":"Yes; encryption with TLS V1.3 pre-selected","on Ethernet via NTP":"Yes","HW functional status":"FS01","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"1.9 A; Rated value","Mode selector switch":"1","Number of IO modules":"2 048; max. number of modules / submodules","Password for display":"Yes","Screen diagonal [cm]":"3.45 cm","Integrated (For Data)":"1.5 Mbyte","Number of breakpoints":"8; Breakpoints are only supported in RUN-Solo status","Number of startup OBs":"100","Open IE communication":"Yes","SIMATIC communication":"Yes; Only Server","Counting and measuring":"Yes","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"1 000","Status/control variable":"Yes","For Bit Operations, Typ.":"80 ns","Integrated (For Program)":"300 kbyte","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of program alarms":"300","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"500","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Word Operations, Typ.":"96 ns","Number of delay alarm OBs":"20","Number of variables, max.":"200","Number of elements (total)":"4 000; Blocks (OB, FB, FC, DB) and UDTs","Memory size per trace, max.":"512 kbyte","Number of connections, max.":"88","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"No","S7 communication, as server":"Yes","Vertical Installation, Max.":"40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off","Vertical Installation, Min.":"0 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off","Horizontal Installation, Min.":"0 °C","Number of PROFINET interfaces":"1","Number of configurable Traces":"4","Industrial Ethernet status LED":"Yes","MRP interconnection, supported":"Yes; as MRP ring node according to IEC 62439-2 Edition 3.0","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"128 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"1","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"0.7 A","Number of subprocess images, max.":"32","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"512 ns","Joint commission (Team Engineering)":"No","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms; PROFINET MRP","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of stations in the ring, max.":"50; Only 16 are recommended, however","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"64","Number of alarms for system diagnostics":"100","Number of slots for SIMATIC memory card":"1","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"5 ms","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000; Program messages are generated by the \"Program_Alarm\" block, ProDiag or GRAPH","Number of connections reserved for ES/HMI/web":"10","Protection Of Confidential Configuration Data":"Yes","Several Passive Connections Per Port, Supported":"Yes","Number of loadable program messages in RUN, max.":"2 500","Number of login stations for message functions, max.":"32","STEP 7 TIA Portal configurable/integrated from version":"V17 (FW V2.9) / V16 (FW V2.8) / V15.1 (FW V2.6)","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$6,676.99 – $7,228.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce9ac6d45726561f85da09d9c983a054.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265871&mlfb=6ES7513-1RL00-0AB0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7513-1RL00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7513-1RL00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}