{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7514-2VN03-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7514-2VN03-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7514-2VN03-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7514-2VN03-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 CPU 1514-2 PN, 100×117×75 mm, 32 kB input/output process image, DCP Yes, DNS Yes, MRP Yes, I2t 0.3 A²·s.","salesMarkdown":"## CPU 1514-2 PN for mid-range automation Siemens 6ES7514-2VN03-0AB0 provides a 32 kbyte process image on both inputs and outputs, supporting LAD, FBD, SCL, STL, and GRAPH programming. The unit carries DCP, DNS, DHCP, LLDP, and SNMP out of the box, and handles MRP (Media Redundancy Protocol) as Manager, Automanager, and Client — enough to build a ring with sub-200 ms recovery. MODBUS TCP is also included for linking to drives or HMIs that don't speak PROFINET natively. No IRT and no PROFIsafe on this CPU. It supports UDP for peer-to-peer communication. ## Key specs for panel integration Dimensions: 100 mm wide, 117 mm tall, 75 mm deep. I²t rating of 0.3 A²·s applies to the internal short-circuit protection — keep the external circuit breaker within that let-through curve to avoid nuisance trips. Integrated PID-Temp controller (up to 40 probes) and for valve positioning cut the need for a separate loop controller on temperature or slow analogue loops.","metaTitle":"Siemens 6ES7514-2VN03-0AB0 CPU 1514-2 PN, 32 kB I/O, DCP, MR","metaDescription":"Siemens 6ES7514-2VN03-0AB0 S7-1500 CPU with 32 kB process image, supports LAD, FBD, SCL, STL, GRAPH, DCP, DNS, MRP, and PID-Temp. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DCP":"Yes","DNS":"Yes","FBD":"Yes","I2t":"0.3 A²·s","IRT":"No","LAD":"Yes","MRP":"Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"Yes","HTTP":"Yes; Standard and user pages","LLDP":"Yes","MRPD":"Yes; Requirement: IRT","SNMP":"Yes","Type":"Hardware clock","Depth":"75 mm","GRAPH":"Yes","HTTPS":"Yes; Standard and user pages","Width":"100 mm","title":"6ES7514-2VN03-0AB0","Height":"117 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"16","RS 485":"Yes; Via CM DP module","TCP/IP":"Yes","Via CM":"0","Forcing":"Yes","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","I&M data":"Yes; I&M0 to I&M3","PID-Temp":"Yes; PID controller with integrated optimization for temperature","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","PROFIsafe":"No","Per Probe":"40","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Encryption":"Yes; Optional","Integrated":"2","S7 routing":"Yes","Size, max.":"16 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","IP protocol":"Yes; IPv4","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes; per user program","Single step":"No","Upper Limit":"adjustable maximum cycle time","Via Dataset":"Yes","description":"SIMATIC DP, CPU 1514SP T-2 PN for ET 200SP, central processing unit with work memory 900 KB for program and 3.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT 6 ns bit performance, SIMATIC Memory Card required, BusAdapter required for 1st interface **** approvals and certificate entry 109817813 at support.industry.siemens.com ****","Autocrossing":"Yes","Equidistance":"No","Number range":"0 ... 65 535","RUN/STOP LED":"Yes","Status block":"Yes; Up to 8 simultaneously (in total across all ES clients)","in AS, slave":"Yes","to DP, slave":"Yes; Via CM DP module","OPC UA Client":"Yes; Data Access (registered Read/Write), Method Call","OPC UA Server":"Yes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space","Per Cam Track":"160","Shared device":"Yes","UDP multicast":"Yes; max. 118 multicast circuits","in AS, master":"Yes","to DP, master":"Yes; Via CM DP module","Motion Control":"Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool","Per Output Cam":"20","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"1","Weight, approx.":"265 g","lifecycle_stage":"current","Block protection":"Yes","Firmware version":"V3.0","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"Yes; only via BusAdapter","Outputs (volume)":"8 kbyte","Power loss, typ.":"6.5 W","RJ 45 (Ethernet)":"Yes; X2","Rated value (DC)":"24 V","Data length, max.":"2 kbyte; 1 472 bytes for UDP broadcast","H-Sync forwarding":"Yes","Integrated Switch":"No","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","Optical interface":"No","PROFIBUS DP slave":"Yes","Security policies":"available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss","FW update possible":"Yes","Forcing, variables":"Peripheral inputs/outputs","High-speed counter":"Yes","PROFIBUS DP master":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24","Retentivity preset":"No","Data record routing":"Yes","PG/OP communication":"Yes; encryption with TLS V1.3 pre-selected","Prioritized startup":"No","User authentication":"\"anonymous\" or by user name & password","on Ethernet via NTP":"Yes","Direct data exchange":"No","HW functional status":"FS01","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"1.34 A; Rated value","Mode selector switch":"1","Number of IO modules":"8 192; max. number of modules / submodules","Per External Encoder":"80","Per Positioning Axis":"80","Per Synchronous Axis":"160","Alarms and Conditions":"Yes","BusAdapter (PROFINET)":"Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12","Integrated (For Data)":"3.5 Mbyte","Number of breakpoints":"8","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes; Optionally also encrypted","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules","Of Which In Line, Max.":"32","PROFINET IO Controller":"Yes","Per leading axis proxy":"3","Retentivity adjustable":"Yes","Asset management record":"Yes; per user program","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"3 200","SIMATIC Safe Kinematics":"No","Sampling interval, min.":"100 ms","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"See online help (S7 communication, user data size)","User-Defined Kinematics":"No","For Bit Operations, Typ.":"6 ns","Integrated (For Program)":"900 kbyte","Number of DPV1 alarm OBs":"3","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of program alarms":"1 000","Number of sessions, max.":"48","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"500","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","Runtime license required":"Yes; \"Medium\" license required","Current consumption, max.":"0.7 A","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"7 ns","Number of DP slaves, max.":"125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET","Number of delay alarm OBs":"20","Number of variables, max.":"200","Per Speed-Controlled Axis":"40","Publishing interval, min.":"100 ms","Application authentication":"Yes","For Each Set Of Kinematics":"30","Number of S7 routing paths":"16","Number of elements (total)":"8 000; Blocks (OB, FB, FC, DB) and UDTs","Number of connections, max.":"10","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; No condensation","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; No condensation","Number of PROFIBUS interfaces":"1; Via CM DP module","Number of PROFINET interfaces":"2","Number of configurable Traces":"4; Up to 512 KB of data per trace are possible","Address space per module, max.":"288 byte; For input and output data respectively","Industrial Ethernet status LED":"Yes","MRP interconnection, supported":"Yes; as MRP ring node according to IEC 62439-2 Edition 3.0","Number of cyclic interrupt OBs":"20; With minimum OB 3x cycle of 250 µs","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Number of server methods, max.":"50","Address space per station, max.":"2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules","Number of connections per CP/CM":"32","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"9 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"0.51 A","Infeed power to the backplane bus":"8.05 W","Number of server interfaces, max.":"10 of each \"Server interfaces\" / \"Companion specification\" type and 20 of the type \"Reference namespace\"","Number of subprocess images, max.":"32","Number of registerable nodes, max.":"20 000","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"37 ns","Joint commission (Team Engineering)":"Yes; Parallel online access possible for up to 8 engineering systems","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms; For MRP, bumpless for MRPD","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Activation/deactivation of DP slaves":"Yes","Number of accessible variables, max.":"100 000","Number of stations in the ring, max.":"50","activation/deactivation of I-devices":"Yes; per user program","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET","Per Cam (1 000 Points And 50 Segments)":"2","Number of alarms for system diagnostics":"200","Number of slots for SIMATIC memory card":"1","Per Cam (10 000 Points And 50 Segments)":"20","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"10 ms","Number of subscriptions per session, max.":"50","Kinematics With Up To 4 Interpolating Axes":"Yes; max. 3D + orientation","Monitoring of the supply voltage (PWR-LED)":"Yes","Number of technology synchronous alarm OBs":"2","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Number of monitored items, recommended max.":"4 000; for 1 s sampling interval and 1 s send interval","Quantity of operable ET 200AL modules, max.":"16","Quantity of operable ET 200SP modules, max.":"64","User program protection/password protection":"Yes","Kinematics With 5 Or More Interpolating Axes":"No","Number of configurable program messages, max.":"10 000; Program messages are generated by the \"Program_Alarm\" block, ProDiag or GRAPH","Number of connectable IO Devices for RT, max.":"32","Number of connections reserved for ES/HMI/web":"10","Protection Of Confidential Configuration Data":"Yes","Number of alarms for motion technology objects":"160","Module swapping during operation (hot swapping)":"Yes; Multi-hot swapping","Number of connections via integrated interfaces":"128","Several Passive Connections Per Port, Supported":"Yes","Number of inputs/outputs per server method, max.":"20","Number of loadable program messages in RUN, max.":"5 000","Number of IO Controllers with shared device, max.":"4","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Number of login stations for message functions, max.":"64","STEP 7 TIA Portal configurable/integrated from version":"V18 (FW V3.0)","Number of nodes for user-defined server interfaces, max.":"30 000","Retentive data area (incl. timers, counters, flags), max.":"512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB","Number of nodes of the client interfaces, recommended max.":"2 000","Number of inputs/outputs when calling OPC_UA_MethodCall, max.":"20","Number of registerable method calls of OPC_UA_MethodCall, max.":"100","Number of available Motion Control resources for technology objects":"2 400","Number of elements for one call of OPC_UA_MethodGetHandleList, max.":"100","Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.":"20","Number of positioning axes at motion control cycle of 4 ms (typical value)":"11","Number of positioning axes at motion control cycle of 8 ms (typical value)":"20","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8; in total across all interfaces","Number of available Extended Motion Control resources for technology objects":"120","Number of simultaneous calls of the client instructions for data access, per connection, max.":"5","Number of simultaneous calls of the client instructions for session management, per connection, max.":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,587.50","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce9ac6d45726561f85da09d9c983a054.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1647423&mlfb=6ES7514-2VN03-0AB0"},"ai":{"faq":[{"question":"Does the 6ES7514-2VN03-0AB0 support PROFIsafe?","answer":"No. For safety over PROFINET you need a CPU with integrated F-capability, like the 6ES7516-3AN03-0AB0 or a separate F-CPU. This unit is standard logic only."},{"question":"What is the process image size?","answer":"32 kB for inputs and 32 kB for outputs — all I/O is in the process image by default, so no forced partial update or overlap handling required."},{"question":"Does it include integrated PID control?","answer":"Yes. PID-Temp with support for up to 40 temperature probes and PID_3Step for valve applications. Configuration is done in TIA Portal — no add-on block required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7514-2VN03-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7514-2VN03-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}