{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7522-1BL10-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7522-1BL10-0AA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7522-1BL10-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7522-1BL10-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 digital output module, 6ES7522-1BL10-0AA0, DQ Yes, MSO Yes, 24 V DC, 25 mm width, supplied with 40-pole push-in front connectors. SIL2 rated, 3.8 W power loss.","salesMarkdown":"The 6ES7522-1BL10-0AA0: At 25 mm wide and 129 mm deep, it fits the standard S7-1500 rack and leaves adjacent slots free for I/O or communication modules. SIL 2 rated. The module occupies one slot on the S7-1500 rail. The 40-pole push-in connectors accept wire sizes typical for digital outputs; terminals are clearly marked for channel assignment. Firmware version V1.0.0, HW functional status from FS01. FW can be updated in the field via TIA Portal. No isochronous mode, but prioritized startup is supported. Green RUN LED and red ERROR LED provide on-module status; no per-channel diagnostics. Lifecycle stage is current — no end-of-life or last-time-buy notices. Suitable for new designs and as a spare for existing S7-1500 installations.","metaTitle":"Siemens 6ES7522-1BL10-0AA0 S7-1500 DO Module, 24V DC, 25mm","metaDescription":"Active S7-1500 digital output module, 24V DC, SIL2 rated. Ships with 40-pole push-in front connectors. 25mm wide, 3.8W.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"DQ":"Yes","MSO":"Yes","PWM":"No","Depth":"129 mm","Note:":"Supplied incl. 40-pole push-in front connectors","Width":"25 mm","Height":"147 mm","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","Wire-break":"No","Group error":"No","Lower Limit":"48 Ω","Upper Limit":"12 kΩ","For Uprating":"No","Oversampling":"No","Short-circuit":"No","Shielded, Max.":"1 000 m","For Logic Links":"Yes","Weight, approx.":"280 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"100 µs","\"1\" To \"0\", Max.":"500 µs","Current-sourcing":"Yes","Diagnostic alarm":"No","Firmware version":"V1.0.0","Isochronous mode":"No","Power loss, typ.":"3.8 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","FW update possible":"Yes","On Lamp Load, Max.":"10 Hz","Prioritized startup":"Yes","Between The Channels":"No","Diagnostics function":"No","For Signal \"1\", Min.":"L+ (-0.8 V)","HW functional status":"From FS01","Isolation tested with":"707 V DC (type test)","Maintenance interrupt":"No","SIL acc. to IEC 62061":"SIL 2","Channel status display":"Yes; green LED","For Module Diagnostics":"No","Type of digital output":"Transistor","Current per group, max.":"4 A; see additional description in the manual","For Channel Diagnostics":"No","Current per module, max.":"16 A; see additional description in the manual","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Current consumption, max.":"60 mA","Current per channel, max.":"0.5 A; see additional description in the manual","Number of digital outputs":"32","With Inductive Load, Max.":"0.5 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.5 A","Controlling a digital input":"Yes","Reverse polarity protection":"Yes; through internal protection with 7 A per group","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-30 °C; from FS04","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; from FS04","Monitoring the supply voltage":"No","Substitute values connectable":"No","Suitable for safety functions":"No","DQ with energy-saving function":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"No","Category according to ISO 13849-1":"Cat. 3","Between The Channels, In Groups Of":"8","Remark On Safety-Oriented Shutdown":"https://support.industry.siemens.com/cs/de/de/view/39198632","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Between The Channels And Backplane Bus":"Yes","For Signal \"1\" Permissible Range, Max.":"0.5 A","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"1.15 W","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Performance level according to ISO 13849-1":"PL d","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Limitation of inductive shutdown voltage to":"L+ (-53 V)","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","STEP 7 TIA Portal configurable/integrated from version":"V13 / V13","Suitable for safety-related tripping of standard modules":"Yes; From FS02"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$276.86","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2fb5ce6832f15b2cea64f78f8981bdca.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=510565&mlfb=6ES7522-1BL10-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7522-1BL10-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is DQ on this module?","answer":"DQ is Yes, confirming it is a digital output module."},{"question":"What is MSO on this module?","answer":"MSO is Yes. This indicates support for safety-related output functions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7522-1BL10-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7522-1BL10-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}