{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7523-1BP50-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7523-1BP50-0AA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7523-1BP50-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7523-1BP50-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 digital input/output module, 6ES7523-1BP50-0AA0, combining DI, DQ, MSI, and MSO on a 35 x 147 x 129 mm form factor, rated 24 V DC, 4.7 W power loss.","salesMarkdown":"## What this module does on the S7-1500 backplane The 6ES7523-1BP50-0AA0 is a mixed digital input/output module for the Siemens S7-1500 system, combining four channel types on one unit: digital inputs (DI), digital outputs (DQ), module-specific inputs (MSI), and module-specific outputs (MSO). It runs on a 24 V DC rated supply and dissipates 4.7 W typical power loss, which sets the thermal budget for the adjacent slot in the rack. The module accepts both source and sink input wiring — the signal thresholds are defined as -5 to +5 V for logic 0 and -11 to -30 V or +11 to +30 V for logic 1, referenced to COM. This means it can interface with PNP or NPN field devices without rewiring the common rail. ## Integration into the panel — what the dimensions and cabling tell you The module measures 35 mm wide, 147 mm high, and 129 mm deep — a compact slice that fits the standard S7-1500 DIN-rail footprint. The 35 mm width is one slot position on the rail, so you can estimate the total rack width from the module count. Cable and connection modules are ordered separately — the module itself has no fixed wiring terminals. You need the appropriate front connector (e.g., 6ES7592-1AM00-0XB0 for 40-pin or 6ES7592-1BM00-0XB0 for 50-pin) and a pre-assembled cable to the field junction box. Factor this into the BOM and the panel wiring schedule. ## Signal timing and wiring distance limits The input transition from 0 to 1 takes a maximum of 100 µs, and from 1 to 0 a maximum of 500 µs. This is fast enough for most discrete sensing (proximity switches, limit switches, pushbuttons) but not for high-speed counting or encoder inputs — the module has no counter function. Maximum cable length is 1 000 m for shielded cable and 600 m for unshielded. In a typical plant-floor installation, shielded cable is recommended for runs beyond 100 m or near variable-frequency drives to avoid noise coupling. ## Lifecycle and sourcing — current production, no cross-reference","metaTitle":"Siemens 6ES7523-1BP50-0AA0 Digital I/O Module, 24 V DC","metaDescription":"Siemens 6ES7523-1BP50-0AA0 digital input/output module for S7-1500. Supports DI, DQ, MSI, MSO. 24 V DC rated, 4.7 W power loss. Current lifecycle.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"DI":"Yes","DQ":"Yes","MSI":"Yes","MSO":"Yes","PWM":"No","Depth":"129 mm","Note:":"Please order cable and connection modules separately","Width":"35 mm","Height":"147 mm","Counter":"No","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","MAINT LED":"No","Wire-break":"No","Group error":"No","Lower Limit":"80 Ω","Upper Limit":"10 kΩ","For Uprating":"No","Oversampling":"No","2-Wire Sensor":"Yes","Short-circuit":"No","For Signal \"0\"":"-5 ... +5 V (reference potential is COM)","For Signal \"1\"":"-11 ... -30 V; +11 ... +30 V (reference potential is COM)","Shielded, Max.":"1 000 m","Current-sinking":"Yes","For Logic Links":"Yes","Parameterizable":"No","Weight, approx.":"250 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"100 µs","\"1\" To \"0\", Max.":"500 µs","Current-sourcing":"No","Diagnostic alarm":"No","Firmware version":"V1.0.0","Isochronous mode":"No","Power loss, typ.":"4.7 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","Source/sink input":"Yes","FW update possible":"Yes","Hardware interrupt":"No","On Lamp Load, Max.":"10 Hz","up to 40 °C, max.":"4 A","up to 60 °C, max.":"4 A","At \"0\" To \"1\", Max.":"4 ms","At \"0\" To \"1\", Min.":"3 ms","At \"1\" To \"0\", Max.":"4 ms","At \"1\" To \"0\", Min.":"3 ms","Prioritized startup":"No","Between The Channels":"No","Diagnostics function":"No","For Signal \"1\", Min.":"M+ (0.5 V)","For Signal \"1\", Typ.":"2.7 mA","HW functional status":"From FS01","Isolation tested with":"707 V DC (type test)","Maintenance interrupt":"No","Channel status display":"Yes; via SIMATIC TOP connect connection module","For Module Diagnostics":"No","Type of digital output":"Transistor","Current per group, max.":"2 A","For Channel Diagnostics":"No","Current per module, max.":"4 A","Number of digital inputs":"32","Short-circuit protection":"No; external fusing necessary, max. 4 A per group, tripping characteristic type B or C","Current consumption, max.":"45 mA; without load","Current per channel, max.":"0.3 A","Number of digital outputs":"32","With Inductive Load, Max.":"0.5 Hz; According to IEC 60947-5-1, DC-13","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.3 A","Controlling a digital input":"Yes","Reverse polarity protection":"Yes; Through internal protection with 4 A per group","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-30 °C","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Monitoring the supply voltage":"No","Substitute values connectable":"No","DQ with energy-saving function":"No","Digital inputs, parameterizable":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"No","Between The Channels, In Groups Of":"16; 32 when using SIMATIC TOP connect connection module","Integrated operating cycle counter":"No","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Between The Channels And Backplane Bus":"Yes","For Signal \"1\" Permissible Range, Max.":"0.3 A","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.35 / -","Power available from the backplane bus":"0.6 W","Monitoring of the supply voltage (PWR-LED)":"Yes; via SIMATIC TOP connect connection module","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"L+ (-53 V)","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Cam control (switching at comparison values)":"No","Number of simultaneously controllable inputs":"32","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","STEP 7 TIA Portal configurable/integrated from version":"V16 with HSP 0319 / V17","External Protection For Power Supply Lines (Recommendation)":"input side: 24 V DC/4 A miniature circuit breaker with type B or C tripping characteristic; output side: 24 V DC/6 A miniature circuit breaker with type B tripping characteristic"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$255.27","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a9d4e2bab9affb14574eaa060873e859.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1448138&mlfb=6ES7523-1BP50-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7523-1BP50-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is 6ES7523-1BP50-0AA0 used for?","answer":"It is a mixed digital input/output module for the Siemens S7-1500 PLC system, combining DI, DQ, MSI, and MSO on one unit. Typical use is in control panels where a combination of discrete sensors and actuators needs to be wired to a single slot, saving rack space and reducing wiring complexity."},{"question":"Is 6ES7523-1BP50-0AA0 sinking or sourcing?","answer":"It supports both source and sink input wiring. The module accepts PNP (source) or NPN (sink) field devices without rewiring the common rail, as long as the voltage thresholds are met: logic 0 at -5 to +5 V, logic 1 at -11 to -30 V or +11 to +30 V referenced to COM."},{"question":"Does 6ES7523-1BP50-0AA0 require connection modules?","answer":"Yes. The module itself has no fixed wiring terminals. Cable and connection modules must be ordered separately. You need a front connector (e.g., 40-pin or 50-pin) and a pre-assembled cable to the field junction box."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7523-1BP50-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7523-1BP50-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}