{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7531-7LH00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7531-7LH00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7531-7LH00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7LH00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1500 analog input module, 6ES7531-7LH00-0AB0, 35 mm wide, four channels across 1–5 V, ±1 V, ±5 V, and ±10 V spans, 200 m shielded wiring.","salesMarkdown":"## What this module is The Siemens 6ES7531-7LH00-0AB0 is an analog input module for the SIMATIC S7-1500 I/O family, designed to digitize low-level voltage signals from field transducers into the backplane for the controller. It drops into a 35 mm slot on the S7-1500 DIN rail, measuring 147 mm tall and 129 mm deep — the standard ET 200MP / S7-1500 module envelope, so it lines up with adjacent digital and analog siblings without special panel prep. ## Measurement ranges and where the diagnostics fire Four voltage spans are supported: 1 V to 5 V, -1 V to +1 V, -5 V to +5 V, and -10 V to +10 V. Wire-break detection is enabled, but only on the 1 V to 5 V range — circuits working in ±1 V, ±5 V, or ±10 V do not raise a wire-break diagnostic, so an open transducer must be caught by the limit-alarm path instead. Resolution is selectable: low, medium, high, and none, which lets the integrator trade noise against conversion time per channel. Each channel reports overflow and underflow, and the module emits a diagnostic alarm plus two upper and two lower limit alarms per channel — enough to bracket a process window and catch out-of-range excursions without leaning on the CPU. ## Field wiring constraints Shielded cable runs top out at 200 m — the integrator plans the conduit path against that ceiling, not the headline sensor range. Front-panel status is RUN (green) and ERROR (red); there is no MAINT LED, so a planned-replacement workflow is signalled through the firmware, not the bezel. Identification and maintenance data I&M0 through I&M3 is stored on the module, which keeps the asset tag, plant designation, and install date queryable from the controller for plant-bookkeeping hooks. ## Power and service Typical power dissipation is 0.75 W, which leaves headroom on the S7-1500 backplane budget when several AI modules are stacked in one station. Firmware ships at V1.0.0 and is field-updatable, so feature additions or bug fixes can be pushed without a swap.","metaTitle":"Siemens 6ES7531-7LH00-0AB0 AI Module, 35 mm, 1–5 V","metaDescription":"Siemens 6ES7531-7LH00-0AB0 SIMATIC AI 4xU/I 16-bit module: lifecycle current, ±10 V / ±5 V / ±1 V / 1–5 V ranges, 35 mm slot, 200 m shielded.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","Depth":"129 mm","Width":"35 mm","title":"6ES7531-7LH00-0AB0","Height":"147 mm","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","ERROR LED":"Yes; red LED","MAINT LED":"No","Step: low":"Yes","0 to +10 V":"No","1 V to 5 V":"Yes","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; Only for 1 ... 5 V","Group error":"No","description":"SIMATIC S7-1500, analog input module AI 16xU BA, 16-bit resolution accuracy 0.5%, 16 channels in groups of 16, common mode voltage 4 V DC, diagnostics, hardware interrupts; delivery including infeed element, shield bracket and shield terminal: front connector (screw terminals or push-in) to be ordered separately","-1 V to +1 V":"Yes","-5 V to +5 V":"Yes","Oversampling":"No","Step: Medium":"Yes","Short-circuit":"No","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes","Weight, approx.":"250 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"No","-25 mV to +25 mV":"No","-50 mV to +50 mV":"No","-80 mV to +80 mV":"No","Diagnostic alarm":"Yes","Firmware version":"V1.0.0","Isochronous mode":"No","Power loss, typ.":"0.75 W","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"No","-500 mV to +500 mV":"No","FW update possible":"Yes","Overflow/underflow":"Yes","Prioritized startup":"No","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"From FS01","Integration time (ms)":"2,5 / 16,67 / 20 / 100 ms","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For voltage measurement":"16","Number of analog inputs":"16","Measuring range scalable":"No","Scalable measured values":"No","between the inputs (UCM)":"8 V DC","Common mode voltage, max.":"4 V","Calibration possible in RUN":"No","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-30 °C","Adjustment of measuring range":"No","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Input resistance (1 V to 5 V)":"10 MΩ","Monitoring the supply voltage":"No","Common mode interference, min.":"60 dB","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"10 MΩ","Between the inputs and MANA (UCM)":"4 V DC","Input resistance (-10 V to +10 V)":"10 MΩ","Integration time, parameterizable":"Yes","Between The Channels, In Groups Of":"16","Crosstalk between the inputs, max.":"-50 dB","Reparameterization possible in RUN":"Yes","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.85 W","Voltage, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"No","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Linearity error (relative to input range), (+/-)":"0.1 %","Temperature error (relative to input range), (+/-)":"0.006 %/K","Additional Conversion Time For Wire-Break Monitoring":"4 ms (to be considered for 1 to 5 V measurement)","Resolution with overrange (bit including sign), max.":"16 bit","Basic conversion time, including integration time (ms)":"10 / 24 / 27 / 107 ms","STEP 7 TIA Portal configurable/integrated from version":"V16 with HSP 312 / V17","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"12 V; 12 V continuous, 30 V for max. 1 s","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$889.18","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/96d96bffae783c1eaab87d82cd9b6a0c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1456252&mlfb=6ES7531-7LH00-0AB0"},"ai":{"faq":[{"question":"What is the maximum shielded cable run to the module?","answer":"200 m for shielded cabling."},{"question":"How wide is the module on the DIN rail?","answer":"35 mm wide, 147 mm tall, 129 mm deep — the standard S7-1500 slot."},{"question":"Can the firmware be updated in the field?","answer":"Yes. Firmware ships at V1.0.0 and is field-updatable, so the module does not need to be swapped for a firmware revision."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7531-7LH00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7531-7LH00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}