{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7531-7NF00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7531-7NF00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7531-7NF00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7NF00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog input module, AI 4xU/I 2-wire ST, 6ES7531-7NF00-0AB0, voltage/current 0-20mA and 1-5V, no thermocouple support, MSI Yes, 35x147x129mm.","salesMarkdown":"The Siemens 6ES7531-7NF00-0AB0 is a 4-channel analog input module for the ET 200SP distributed I/O system, accepting 0 to 20 mA and 1 V to 5 V signals on a 2-wire interface. It does not support thermocouples or RTDs — every TC/RTD type in the spec table is flagged No (Pt100, Pt1000, type K, type J, type B, etc.). If your line-down spare was reading a temperature probe, this module won’t do the job. The module fits the standard ET 200SP form factor: 35 mm wide, 147 mm tall, 129 mm deep. This module carries I&M data (I&M0 to I&M3) for asset tracking — a small but useful detail for panels that log module IDs against the PLC hardware catalog. Mounts directly into an ET 200SP baseUnit (not included). The terminal assignments follow the standard 2-wire AI pinout — no special wiring beyond the 0-20 mA or 1-5 V signal loop. Step resolutions are Low and High (selectable per channel). If you're swapping a failed module on site, power down the rack, pull the old card, clip in this one — the baseUnit stays. The 35 mm width leaves no gap in the rail; verify the baseUnit color (light) matches the module type if your panel uses the keying system.","metaTitle":"Siemens 6ES7531-7NF00-0AB0 SIMATIC ET 200SP AI module, 4xU/I","metaDescription":"Siemens 6ES7531-7NF00-0AB0 analog input module for ET 200SP. 4 channels, voltage/current 0-20mA, 1-5V. No TC/RTD. MSI Yes. 35x147x129mm. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","PTC":"No","Cu 10":"No","Cu 50":"No","Depth":"129 mm","Ni 10":"No","Pt 10":"No","Pt 50":"No","Width":"35 mm","title":"6ES7531-7NF00-0AB0","Cu 100":"No","Height":"147 mm","Ni 100":"No","Ni 120":"No","Ni 200":"No","Ni 500":"No","Pt 100":"No","Pt 200":"No","Pt 500":"No","Type B":"No","Type C":"No","Type E":"No","Type J":"No","Type K":"No","Type L":"No","Type N":"No","Type R":"No","Type S":"No","Type T":"No","Ni 1000":"No","Pt 1000":"No","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","ERROR LED":"Yes; red LED","Step: low":"Yes","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","LG-Ni 1000":"No","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; only for 1 ... 5 V and 4 ... 20 mA","description":"SIMATIC S7-1500 analog input module AI 8xU/I HF, up to 24 bit resolution, accuracy 0.1%, 8 channels in groups of 1; common mode voltage: 30 V AC/60 V DC, Diagnostics; Hardware interrupts Measured values ​​scalable, measuring range adjustment, Calibrate in RUN; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately","-5 V to +5 V":"Yes","Oversampling":"No","Step: Medium":"Yes","0 To 150 Ohms":"No","0 To 300 Ohms":"No","0 To 600 Ohms":"No","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","0 To 3000 Ohms":"No","0 To 6000 Ohms":"No","Shielded, Max.":"800 m","Parameterizable":"Yes","Weight, approx.":"280 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"Yes","-20 mA to +20 mA":"Yes","-25 mV to +25 mV":"No","-50 mV to +50 mV":"No","-80 mV to +80 mV":"No","Diagnostic alarm":"Yes","Firmware version":"V1.1.0","Isochronous mode":"No","Power loss, typ.":"1.9 W","Rated value (DC)":"24 V","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"No","-500 mV to +500 mV":"No","FW update possible":"Yes","Overflow/underflow":"Yes","Prioritized startup":"Yes","Between The Channels":"Yes","Diagnostics function":"Yes","HW functional status":"From FS01","Integration time (ms)":"Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms","Isolation tested with":"2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Cu 10 according to GOST":"No","Cu 50 according to GOST":"No","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"8","For voltage measurement":"8","Ni 10 according to GOST":"No","Note Regarding Accuracy":"at temperatures below 0 °C, the figures for operating error and temperature error are doubled","Number of analog inputs":"8","Pt 10 according to GOST":"No","Pt 50 according to GOST":"No","Type TXK/TXK(L) to GOST":"No","Cu 100 according to GOST":"No","Measuring range scalable":"No","Ni 100 according to GOST":"No","Ni 120 according to GOST":"No","Ni 200 according to GOST":"No","Ni 500 according to GOST":"No","Pt 100 according to GOST":"No","Pt 200 according to GOST":"No","Pt 500 according to GOST":"No","Scalable measured values":"Yes","Common mode voltage, max.":"60 V DC/30 V AC","Current consumption, max.":"50 mA; with 24 V DC supply","Ni 1000 according to GOST":"No","Pt 1000 according to GOST":"No","Between Different Circuits":"60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-30 °C; From FS02","Adjustment of measuring range":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; From FS02","Input resistance (0 to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (1 V to 5 V)":"100 kΩ","Monitoring the supply voltage":"Yes","Common mode interference, min.":"80 dB","Input resistance (-5 V to +5 V)":"100 kΩ","Input resistance (4 mA to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (-10 V to +10 V)":"100 kΩ","Integration time, parameterizable":"Yes","Between The Channels, In Groups Of":"1","Crosstalk between the inputs, max.":"-80 dB","Reparameterization possible in RUN":"Yes","Input resistance (-2.5 V to +2.5 V)":"100 kΩ","Input resistance (-20 mA to +20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.85 W","Current, relative to input range, (+/-)":"0.05 %","Voltage, relative to input range, (+/-)":"0.05 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 2-Wire Transducer":"Yes; with external transmitter supply","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.02 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","For Resistance Measurement With Two-Wire Connection":"No","For Resistance Measurement With Four-Wire Connection":"No","Resolution with overrange (bit including sign), max.":"24 bit; When using the function \"Scaling of the measured values\" or \"Measuring range adaptation\" (32 bit REAL format); 16 bit when using the S7 format (16 bit INTEGER)","For Resistance Measurement With Three-Wire Connection":"No","Basic conversion time, including integration time (ms)":"Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms","STEP 7 TIA Portal configurable/integrated from version":"V14 / -","Basic execution time of the module (all channels released)":"Corresponds to the channel with the highest basic conversion time","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"28.8 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.02 %","Series mode interference (peak value of interference < rated value of input range), min.":"80 dB; in the Standard operating mode, 40 dB in the Fast operating mode"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$584.20","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a72e60a8e1612d5b4196770b708cbcde.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689601&mlfb=6ES7531-7NF00-0AB0"},"ai":{"faq":[{"question":"What are the physical dimensions of the 6ES7531-7NF00-0AB0?","answer":"The module is 35 mm wide, 147 mm high, and 129 mm deep — standard ET 200SP single-wide form factor. It fits any baseUnit without overhang."},{"question":"Does this module have diagnostic LEDs?","answer":"Yes. It has a green RUN LED and a red ERROR LED for quick visual status at the cabinet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7531-7NF00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7531-7NF00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}