{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7531-7QD00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7531-7QD00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7531-7QD00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7QD00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 analog input module, 6ES7531-7QD00-0AB0, supports MSI and PTC inputs, Pt100/1000 RTDs, and thermocouples, 25 x 147 x 129 mm, supplied with 40-pole front connector.","salesMarkdown":"## Analog input module for S7-1500 with MSI and PTC The Siemens 6ES7531-7QD00-0AB0 is an analog input module for the S7-1500 system that supports MSI (Motor Starter Interface) and PTC thermistor inputs, meaning it can directly read motor temperature sensors and starter diagnostics without an external converter. It accepts Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 RTDs in standard or climate ranges, plus thermocouple types B, E, J, K, N, R, S, T, covering the majority of industrial temperature sensing needs in a single slot. ## Signal types and accuracy The module handles 0 to 20 mA, 1 V to 5 V, and ±50 mV, ±80 mV, ±250 mV voltage ranges, with additional basic error and noise specs for the 2.5 ms integration time: voltage accuracy within ±0.02% to ±0.05% depending on range, and Pt100 climate accuracy within ±0.08 K. Thermocouple accuracy at the same integration time is ±3 K for types B, R, S and ±1 K for types E, J, K, N, T, which is adequate for process monitoring and oven control loops. The module does not support Cu10, Cu50, Cu100, Ni10, Ni120, Ni200, Ni500, Pt10, Pt50, or thermocouple types C, L, U — confirm your sensor type against the supported list before specifying. ## Status indication and identification A green RUN LED and a red ERROR LED on the front panel give immediate visual status — the RUN LED confirms the module is configured and communicating, the ERROR LED flags a wiring or parameter fault. I&M data (I&M0 to I&M3) is supported, so the module carries manufacturer, location, and date identifiers that the TIA Portal reads for asset tracking and maintenance records. This module is supplied with a 40-pole push-in front connector, so no separate connector order is needed for the first installation.","metaTitle":"Siemens 6ES7531-7QD00-0AB0 Analog Input Module, MSI, PTC","metaDescription":"Siemens 6ES7531-7QD00-0AB0 analog input module for S7-1500. Supports MSI, PTC, Pt100, thermocouples. 25 mm width, 129 mm depth.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","PTC":"Yes","Cu 10":"No","Cu 50":"No","Depth":"129 mm","Ni 10":"No","Note:":"Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K","Pt 10":"No","Pt 50":"No","Width":"25 mm","Cu 100":"No","Height":"147 mm","Ni 100":"Yes; Standard/climate","Ni 120":"No","Ni 200":"No","Ni 500":"No","Pt 100":"Yes; Standard/climate","Pt 200":"Yes; Standard/climate","Pt 500":"Yes; Standard/climate","Type B":"Yes","Type C":"No","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"No","Type N":"Yes","Type R":"Yes","Type S":"Yes","Type T":"Yes","Type U":"No","Ni 1000":"Yes; Standard/climate","Pt 1000":"Yes; Standard/climate","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","ERROR LED":"Yes; red LED","Step: low":"Yes","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","LG-Ni 1000":"Yes; Standard/climate","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD","-1 V to +1 V":"Yes","-5 V to +5 V":"Yes","Oversampling":"No","Step: Medium":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","0 To 3000 Ohms":"No","0 To 6000 Ohms":"Yes","Shielded, Max.":"800 m; for U/I, 200 m for R/RTD, 50 m for TC","Parameterizable":"Yes","Weight, approx.":"210 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"Yes","-20 mA to +20 mA":"Yes","-25 mV to +25 mV":"No","-50 mV to +50 mV":"Yes","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes","Firmware version":"V1.0.0","Isochronous mode":"No","Power loss, typ.":"2.3 W","Rated value (DC)":"24 V","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"Yes","-500 mV to +500 mV":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Prioritized startup":"No","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"From FS01","Output current, max.":"20 mA; Max. 47 mA per channel for a duration < 10 s","Integration time (ms)":"2,5 / 16,67 / 20 / 100 ms","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Input resistance (PTC)":"10 MΩ","Cu 10 according to GOST":"No","Cu 50 according to GOST":"No","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"4","For voltage measurement":"4","Ni 10 according to GOST":"No","Note Regarding Accuracy":"at temperatures below 0 °C, the figures for operating error and temperature error are doubled","Number of analog inputs":"4","Pt 10 according to GOST":"No","Pt 50 according to GOST":"No","Type TXK/TXK(L) to GOST":"No","Cu 100 according to GOST":"No","Measuring range scalable":"No","Ni 100 according to GOST":"No","Ni 120 according to GOST":"No","Ni 200 according to GOST":"No","Ni 500 according to GOST":"No","Pt 100 according to GOST":"No","Pt 200 according to GOST":"No","Pt 500 according to GOST":"No","Scalable measured values":"No","Short-circuit protection":"Yes","between the inputs (UCM)":"20 V DC","Common mode voltage, max.":"10 V","Current consumption, max.":"165 mA","Input resistance (Ni 100)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Input resistance (Pt 200)":"10 MΩ","Input resistance (Pt 500)":"10 MΩ","Input resistance (Type B)":"10 MΩ","Input resistance (Type E)":"10 MΩ","Input resistance (Type K)":"10 MΩ","Input resistance (Type N)":"10 MΩ","Input resistance (Type R)":"10 MΩ","Input resistance (Type S)":"10 MΩ","Input resistance (Type T)":"10 MΩ","Input resistance (type J)":"10 MΩ","Ni 1000 according to GOST":"No","Pt 1000 according to GOST":"No","Input resistance (Ni 1000)":"10 MΩ","Input resistance (Pt 1000)":"10 MΩ","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-25 °C; From FS03","For thermocouple measurement":"4","Adjustment of measuring range":"No","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-25 °C; From FS03","Input resistance (0 to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (1 V to 5 V)":"100 kΩ","Input resistance (LG-Ni 1000)":"10 MΩ","Monitoring the supply voltage":"Yes","Analog input with oversampling":"No","Common mode interference, min.":"60 dB","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"100 kΩ","Reference channel of the module":"No","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Between the inputs and MANA (UCM)":"10 V DC","Input resistance (-10 V to +10 V)":"100 kΩ","Input resistance (0 to 6000 ohms)":"10 MΩ","Integration time, parameterizable":"Yes","Internal Temperature Compensation":"Yes","Between The Channels, In Groups Of":"4","Burden of 2-wire transmitter, max.":"820 Ω","Crosstalk between the inputs, max.":"-80 dB","Reparameterization possible in RUN":"Yes","Standardization of measured values":"No","Input resistance (-2.5 V to +2.5 V)":"10 MΩ","Input resistance (-20 mA to +20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (-50 mV to +50 mV)":"10 MΩ","Input resistance (-80 mV to +80 mV)":"10 MΩ","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Input resistance (-250 mV to +250 mV)":"10 MΩ","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.7 W","Current, relative to input range, (+/-)":"0.1 %","Voltage, relative to input range, (+/-)":"0.1 %","Time for offset calibration (per module)":"Basic conversion time of the slowest channel","external temperature compensation via RTD":"Yes","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Resistance, relative to input range, (+/-)":"0.1 %","Temperature error of internal compensation":"±6 °C","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Thermocouple, relative to input range, (+/-)":"0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K","Linearity error (relative to input range), (+/-)":"0.02 %","For resistance/resistance thermometer measurement":"2","Compensation for 0 °C reference point temperature":"Yes; fixed value can be set","Temperature error (relative to input range), (+/-)":"0.005 %/K; With TC type T 0.02 ± % / K","For Resistance Measurement With Two-Wire Connection":"Yes; Only for PTC","Additional Conversion Time For Wire-Break Monitoring":"9 ms (to be considered in R/RTD/TC measurement)","For Resistance Measurement With Four-Wire Connection":"Yes; All measuring ranges except PTC","Resolution with overrange (bit including sign), max.":"16 bit","Additional Conversion Time For Resistance Measurement":"150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms","For Resistance Measurement With Three-Wire Connection":"Yes; All measuring ranges except PTC; internal compensation of the cable resistances","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","Basic conversion time, including integration time (ms)":"9 / 23 / 27 / 107 ms","Resistance thermometer, relative to input range, (+/-)":"0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K","STEP 7 TIA Portal configurable/integrated from version":"V13 / V13.0.2","Between The Channels And The Power Supply Of The Electronics":"Yes","Constant measurement current for resistance-type transmitter, typ.":"150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"28.8 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.02 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$227.33","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8bd0f9df7be4f91fa449e559df4104c1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=409081&mlfb=6ES7531-7QD00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7QD00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 6ES7531-7QD00-0AB0 and get current pricing?","answer":"The 6ES7531-7QD00-0AB0 is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and current pricing."},{"question":"Is 6ES7531-7QD00-0AB0 compatible with Siemens S7-1500?","answer":"Yes, this is an S7-1500 analog input module designed for the S7-1500 backplane bus, occupying one slot at 25 mm width."},{"question":"Does 6ES7531-7QD00-0AB0 support Pt100 RTD inputs?","answer":"Yes, it supports Pt100 in standard and climate ranges, along with Pt200, Pt500, Pt1000, Ni100, and Ni1000."},{"question":"What is the MSI function on 6ES7531-7QD00-0AB0?","answer":"MSI (Motor Starter Interface) is supported, allowing the module to read diagnostics and status from Siemens motor starters directly without additional wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7531-7QD00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7531-7QD00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}