{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7531-7QF00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7531-7QF00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7531-7QF00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7QF00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1500 analog input module, 6ES7531-7QF00-0AB0, 8 channels, MSI, PTC, depth 129 mm.","salesMarkdown":"The Siemens 6ES7531-7QF00-0AB0 is an 8-channel analog input module for the S7-1500 system. It handles RTDs (Pt100, Ni100, Pt1000, Ni1000 standard/climate), voltage (1-5 V), and current (0-20 mA). MSI and PTC inputs are built in—MSI powers 2-wire transmitters directly, PTC connects motor thermal protection without external relays. The module fits a standard S7-1500 slot: 35 mm wide, 147 mm tall, 129 mm deep. Status indication via green RUN LED and red ERROR LED.","metaTitle":"Siemens 6ES7531-7QF00-0AB0 Analog Input Module MSI PTC","metaDescription":"6ES7531-7QF00-0AB0 S7-1500 analog input module with MSI and PTC. Accepts RTDs, 0-20mA, 1-5V. Depth 129mm. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","PTC":"Yes","Cu 10":"No","Cu 50":"No","Depth":"129 mm","Ni 10":"No","Pt 10":"No","Pt 50":"No","Width":"35 mm","Cu 100":"No","Height":"147 mm","Ni 100":"Yes; Standard/climate","Ni 120":"No","Ni 200":"No","Ni 500":"No","Pt 100":"Yes; Standard/climate","Pt 200":"No","Pt 500":"No","Type B":"No","Type C":"No","Type E":"No","Type J":"No","Type K":"No","Type L":"No","Type N":"No","Type R":"No","Type S":"No","Type T":"No","Type U":"No","Ni 1000":"Yes; Standard/climate","Pt 1000":"Yes; Standard/climate","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","ERROR LED":"Yes; red LED","MAINT LED":"No","Step: low":"Yes","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","LG-Ni 1000":"Yes; Standard/climate","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; Only for 1 ... 5 V, 4 ... 20 mA, R, and RTD","Group error":"No","-1 V to +1 V":"Yes","-5 V to +5 V":"Yes","Oversampling":"No","Step: Medium":"Yes","0 To 150 Ohms":"No","0 To 300 Ohms":"No","0 To 600 Ohms":"Yes","4 mA to 20 mA":"Yes","Short-circuit":"No","-10 V to +10 V":"Yes","0 To 3000 Ohms":"No","0 To 6000 Ohms":"Yes","Shielded, Max.":"200 m; 50 m at 50 mV","Parameterizable":"Yes","Weight, approx.":"250 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"No","-20 mA to +20 mA":"Yes","-25 mV to +25 mV":"No","-50 mV to +50 mV":"Yes","-80 mV to +80 mV":"No","Diagnostic alarm":"Yes","Firmware version":"V1.0.0","Power loss, typ.":"0.9 W","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"No","-500 mV to +500 mV":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Prioritized startup":"No","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"FS01","Integration time (ms)":"2,5 / 16,67 / 20 / 100 ms","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Input resistance (PTC)":"10 MΩ","Cu 10 according to GOST":"No","Cu 50 according to GOST":"No","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"8","For voltage measurement":"8","Ni 10 according to GOST":"No","Number of analog inputs":"8","Pt 10 according to GOST":"No","Pt 50 according to GOST":"No","Type TXK/TXK(L) to GOST":"No","Cu 100 according to GOST":"No","Ni 100 according to GOST":"No","Ni 120 according to GOST":"No","Ni 200 according to GOST":"No","Ni 500 according to GOST":"No","Pt 100 according to GOST":"No","Pt 200 according to GOST":"No","Pt 500 according to GOST":"No","between the inputs (UCM)":"8 V DC","Common mode voltage, max.":"4 V","Input resistance (Ni 100)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Ni 1000 according to GOST":"No","Pt 1000 according to GOST":"No","Input resistance (Ni 1000)":"10 MΩ","Input resistance (Pt 1000)":"10 MΩ","Calibration possible in RUN":"No","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"0 °C","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Input resistance (0 to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (1 V to 5 V)":"10 MΩ","Input resistance (LG-Ni 1000)":"10 MΩ","Monitoring the supply voltage":"No","Common mode interference, min.":"60 dB","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Between the inputs and MANA (UCM)":"4 V DC","Input resistance (-10 V to +10 V)":"10 MΩ","Input resistance (0 to 6000 ohms)":"10 MΩ","Integration time, parameterizable":"Yes","Between The Channels, In Groups Of":"8","Crosstalk between the inputs, max.":"-50 dB","Reparameterization possible in RUN":"Yes","Input resistance (-20 mA to +20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (-50 mV to +50 mV)":"10 MΩ","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.85 W","Current, relative to input range, (+/-)":"0.3 %","Voltage, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"No","Resistance, relative to input range, (+/-)":"0.3 %","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 2-Wire Transducer":"Yes; with external supply","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.1 %","For resistance/resistance thermometer measurement":"8","Temperature error (relative to input range), (+/-)":"0.006 %/K","For Resistance Measurement With Two-Wire Connection":"Yes; Only for PTC","Additional Conversion Time For Wire-Break Monitoring":"4 ms (to be considered in R/RTD/U 1 to 5 V measurement)","Resolution with overrange (bit including sign), max.":"16 bit","Additional Conversion Time For Resistance Measurement":"8 ms","For Resistance Measurement With Three-Wire Connection":"Yes; All measuring ranges except PTC; internal compensation of the cable resistances","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","Basic conversion time, including integration time (ms)":"10 / 24 / 27 / 107 ms","Resistance thermometer, relative to input range, (+/-)":"Ptxxx Standard: ±1.0 K, Ptxxx Climate: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Climate: ±0.5 K","STEP 7 TIA Portal configurable/integrated from version":"V15.1 / V16","Constant measurement current for resistance-type transmitter, typ.":"230 ... 370 µA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"12 V; 12 V continuous, 30 V for max. 1 s","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$307.34","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d88ea7d00be1b9cbc844644cf1e4f2e1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1343226&mlfb=6ES7531-7QF00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7531-7QF00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What does the PTC (Yes) spec indicate?","answer":"PTC (Positive Temperature Coefficient) inputs allow direct connection of motor thermal protection elements (like PTC thermistors) to the module for overtemperature monitoring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7531-7QF00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7531-7QF00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}