{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7532-5ND00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7532-5ND00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7532-5ND00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7532-5ND00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1500 analog output module, 35 mm wide, 24 V DC supply, order code 6ES7532-5ND00-0AB0, covering ±10 V, 0–10 V, 1–5 V, 0/4–20 mA and ±20 mA spans with channel diagnostics and SIL 2 rating.","salesMarkdown":"The Siemens 6ES7532-5ND00-0AB0 is a SIMATIC S7-1500 analog output module that drops onto the S7-1500 backplane next to the CPU, occupying a 35 mm slice of DIN real estate at 147 mm tall and 129 mm deep, and it draws 5 W typical from the 24 V DC supply while sitting on the same L+ rail the rest of the station uses. This is the output side of an S7-1500 analog station: the CPU writes a real to the channel, the module drives the corresponding voltage or current out to the field device, and it reports back per-channel and module diagnostics so the controls integrator can see a failed loop without walking the panel. Lifecycle is current production per the spec table, so the part is specified-into-the-BOM rather than chased as last-time-buy. Quote against an RFQ for the supply posture. ## Output spans and field-side behaviour Wire-break detection runs only on the current output type, and short-circuit detection only on the voltage output type — wire the loop to the current setting if you need open-loop visibility, and to the voltage setting if you need a hard short flag on a 0–10 V drive. Settling times land at 0.2 ms on a resistive load, 2 ms on an inductive load, and 1.8 ms on a capacitive load, so a fast proportional valve or a soft-driven actuator both stay inside one settling envelope without reconfiguration. Maximum shielded cable run is 800 m on a current output and 200 m on a voltage output, which is the binding layout number when the junction box sits well away from the cabinet — pull voltage loops short, push current loops where you need distance. ## Diagnostics, isochronous, and safety footprint The module supports isochronous mode and prioritized startup, and carries I&M data from I&M0 to I&M3, so it can be named, identified, and read-back during commissioning without an extra parameter file floating on a laptop. Front-panel indicators give a green RUN LED, a red ERROR LED for module diagnostics, a green channel-status LED per channel, and a red channel-diagnostics LED per channel, which is what the field-service tech reads first when a loop goes flat. Wire-break on the current path and overflow/underflow on the value path are both flagged back to the CPU, which shortens the time between a failed transmitter and a yellow bar in the HMI. ## Configuration, firmware, and accuracy envelope Firmware is V1.1.0 on this build, HW functional status is from FS01, and the firmware is update-capable in the field, so a future revision lands as a routine download rather than a card swap. Below 0 °C the operating error and temperature error figures double, which is the binding clause for any cold-room or outdoor-enclosure deployment — the card still runs, the accuracy envelope just widens on the way down.","metaTitle":"Siemens 6ES7532-5ND00-0AB0 analog output module, 35 mm","metaDescription":"Siemens 6ES7532-5ND00-0AB0 SIMATIC S7-1500 analog output module, 35 mm wide, current production, supports ±10 V, 0/4–20 mA. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Output Modules"],"specifications":{"MSO":"Yes","Depth":"129 mm","Width":"35 mm","title":"6ES7532-5ND00-0AB0","Height":"147 mm","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to 10 V":"Yes","ERROR LED":"Yes; red LED","0 to 20 mA":"Yes","1 V to 5 V":"Yes","Wire-break":"Yes; Only for output type \"current\"","description":"SIMATIC S7-1500, analog output module AQ 4xU/I HF, 16-bit resolution accuracy 0.1%, 4 channels in groups of 1, common mode voltage: 30 V AC/60 V DC, diagnostics; substitute value, isochronous mode; the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:2015. delivery including infeed element, shielding bracket and shield terminal: front connector (screw terminals or push-in) to be ordered separat","-5 V to +5 V":"No","Oversampling":"No","4 mA to 20 mA":"Yes","Short-circuit":"Yes; Only for output type \"voltage\"","-10 V to +10 V":"Yes","Shielded, Max.":"800 m; for current, 200 m for voltage","Weight, approx.":"300 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes","Firmware version":"V1.1.0","Isochronous mode":"Yes","Power loss, typ.":"5 W","Rated value (DC)":"24 V","FW update possible":"Yes","For Inductive Load":"2 ms; see additional description in the manual","For Resistive Load":"0.2 ms; see additional description in the manual","Overflow/underflow":"Yes","For Capacitive Load":"1.8 ms; see additional description in the manual","Prioritized startup":"Yes","Between The Channels":"Yes","Diagnostics function":"Yes","HW functional status":"From FS01","Isolation tested with":"2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus","SIL acc. to IEC 62061":"SIL 2","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","For Channel Diagnostics":"Yes; red LED","Note Regarding Accuracy":"at temperatures below 0 °C, the figures for operating error and temperature error are doubled","Number of analog outputs":"4","Current consumption, max.":"160 mA","Between Different Circuits":"60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels","Bus cycle time (TDP), min.":"250 µs","With Current Outputs, Max.":"750 Ω","With Voltage Outputs, Min.":"1 kΩ; 0.5 kOhm at 1 to 5 V","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-25 °C; From FS02","Conversion time (per channel)":"125 µs; independent of number of activated channels","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-25 °C; From FS02","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Cycle time (all channels), min.":"125 µs; independent of number of activated channels","Category according to ISO 13849-1":"Cat. 3","Between The Channels, In Groups Of":"1","Remark On Safety-Oriented Shutdown":"https://support.industry.siemens.com/cs/de/de/view/39198632","Reparameterization possible in RUN":"Yes","Crosstalk between the outputs, max.":"-100 dB","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Current output, no-load voltage, max.":"22 V","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Voltage Output Two-Wire Connection":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.95 W","For Voltage Output Four-Wire Connection":"Yes","Between the channels and load voltage L+":"Yes","Current, relative to output range, (+/-)":"0.1 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.06 %","Execution and activation time (TCO), min.":"100 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Performance level according to ISO 13849-1":"PL d","With Current Outputs, Inductive Load, Max.":"10 mH","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Voltage output, short-circuit current, max.":"24 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Linearity error (relative to output range), (+/-)":"0.015 %","Temperature error (relative to output range), (+/-)":"0.002 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V14 / -","Suitable for safety-related tripping of standard modules":"Yes; From FS03","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.02 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.005 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$502.92","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/884ccd0b5b6dcfe1750fc2cc658e9281.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689603&mlfb=6ES7532-5ND00-0AB0"},"ai":{"faq":[{"question":"What is the MSO status on 6ES7532-5ND00-0AB0?","answer":"The MSO flag is Yes on this order code per the spec table."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7532-5ND00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7532-5ND00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}