{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7534-7QE00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7534-7QE00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7534-7QE00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7534-7QE00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1500 analog input module, AI 4×U/I TC, order code 6ES7534-7QE00-0AB0, 25 mm wide, supports thermocouples B, E, J, K, N, R, S, T and 0–10 V input, supplied with 40-pole push-in front connector.","salesMarkdown":"The Siemens 6ES7534-7QE00-0AB0 is the SIMATIC S7-1500 AI 4×U/I TC analog input module — four channels built around MSI (Yes), MSO (Yes) and PTC (Yes) handling on a 25 mm wide, 147 mm tall, 129 mm deep front plate. It ships with the 40-pole push-in front connector already in the box, so first-fit on the ET 200MP / S7-1500 rack is one card, one connector, one turn of the locking screw. Across the S7-1500 family, the AI 4×U/I TC sits in the same shell as the standard analog cards but is the variant specified where thermocouples and RTDs are the field — its thermocouple list is type B, E, J, K, N, R, S, T; Cu10, Cu50, Cu100, Ni120, Ni200, Ni500, Pt10, Pt50 and Type C / Type L / Type U thermocouples are not in the spec set. ## Voltage, RTD, and TC envelope Voltage input is rated for 0 to 10 V; 0 to +5 V and 0 to +10 V are explicitly out of the module's rating envelope. RTD coverage runs to Pt100, Pt200, Pt500 and Pt1000 plus Ni100 and Ni1000, all at Standard/climate — enough for the conventional Pt100 temperature probes and the lower-resistance Pt/Ni standards a process panel will throw at it, but not the older copper or high-ohm nickel variants listed above. Basic error and noise are stated for integration time 2.5 ms: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%) on voltage; 150 Ohms (±0.02%) on resistance; Pt100 climate ±0.08 K and Ni100 climate ±0.08 K on resistance thermometers; type B, R, S thermocouples ±3 K, and types E, J, K, N, T ±1 K. The ±1 K vs ±3 K spread between the high-temperature platinum types (B, R, S) and the rest is what governs whether a process loop's calibration budget tolerates this card without an external cold-junction box.","metaTitle":"Siemens 6ES7534-7QE00-0AB0 AI 4xU/I TC, 25 mm","metaDescription":"Siemens SIMATIC S7-1500 analog input module 6ES7534-7QE00-0AB0: 4 channels, thermocouples B/E/J/K/N/R/S/T, 0–10 V, 25 mm wide, supplied with 40-pole push-in front connector.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","MSO":"Yes","PTC":"Yes","Cu 10":"No","Cu 50":"No","Depth":"129 mm","Ni 10":"No","Note:":"Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K","Pt 10":"No","Pt 50":"No","Width":"25 mm","title":"6ES7534-7QE00-0AB0","Cu 100":"No","Height":"147 mm","Ni 100":"Yes; Standard/climate","Ni 120":"No","Ni 200":"No","Ni 500":"No","Pt 100":"Yes; Standard/climate","Pt 200":"Yes; Standard/climate","Pt 500":"Yes; Standard/climate","Type B":"Yes","Type C":"No","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"No","Type N":"Yes","Type R":"Yes","Type S":"Yes","Type T":"Yes","Type U":"No","Ni 1000":"Yes; Standard/climate","Pt 1000":"Yes; Standard/climate","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","0 to 10 V":"Yes","ERROR LED":"Yes; red LED","Step: low":"Yes","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","LG-Ni 1000":"Yes; Standard/climate","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; only for input type 1 ... 5 V, 4 ... 20 mA, TC, R, RTD and output type current","description":"SIMATIC S7-1500 Analog input/output module AI 4x U/I/R/RTD/TC ST; 4 channels in groups of 4; Hardware interrupts; Diagnostics AQ 2x U/I ST; 2 channels in groups of 2; Substitute value; Diagnostics Common mode voltage approx. 10 V 16 bit; Accuracy 0.3%; Delivery including push-in front connector, infeed element, shield bracket and shield terminal","-1 V to +1 V":"Yes","-5 V to +5 V":"No","Oversampling":"No","Step: Medium":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","4 mA to 20 mA":"Yes","Short-circuit":"Yes; Only for output type \"voltage\"","-10 V to +10 V":"Yes","0 To 3000 Ohms":"No","0 To 6000 Ohms":"Yes","Shielded, Max.":"800 m; for current, 200 m for voltage","Parameterizable":"Yes","Weight, approx.":"250 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"Yes","-20 mA to +20 mA":"Yes","-25 mV to +25 mV":"No","-50 mV to +50 mV":"Yes","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes","Firmware version":"V1.0.0","Isochronous mode":"No","Power loss, typ.":"3.3 W","Rated value (DC)":"24 V","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"Yes","-500 mV to +500 mV":"Yes","FW update possible":"Yes","For Inductive Load":"2.5 ms","For Resistive Load":"1.5 ms","Overflow/underflow":"Yes","For Capacitive Load":"2.5 ms","Prioritized startup":"No","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"From FS01","Output current, max.":"20 mA; Max. 47 mA per channel for a duration < 10 s","Integration time (ms)":"2,5 / 16,67 / 20 / 100 ms","Isolation tested with":"707 V DC (type test)","Output range scalable":"No","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Input resistance (PTC)":"10 MΩ","Cu 10 according to GOST":"No","Cu 50 according to GOST":"No","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"4","For voltage measurement":"4","Ni 10 according to GOST":"No","Note Regarding Accuracy":"at temperatures below 0 °C, the figures for operating error and temperature error are doubled","Number of analog inputs":"4","Pt 10 according to GOST":"No","Pt 50 according to GOST":"No","Type TXK/TXK(L) to GOST":"No","Cu 100 according to GOST":"No","Measuring range scalable":"No","Ni 100 according to GOST":"No","Ni 120 according to GOST":"No","Ni 200 according to GOST":"No","Ni 500 according to GOST":"No","Number of analog outputs":"2","Pt 100 according to GOST":"No","Pt 200 according to GOST":"No","Pt 500 according to GOST":"No","Scalable measured values":"No","Short-circuit protection":"Yes","between the inputs (UCM)":"20 V DC","Common mode voltage, max.":"10 V","Current consumption, max.":"200 mA","Input resistance (Ni 100)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Input resistance (Pt 200)":"10 MΩ","Input resistance (Pt 500)":"10 MΩ","Input resistance (Type B)":"10 MΩ","Input resistance (Type E)":"10 MΩ","Input resistance (Type K)":"10 MΩ","Input resistance (Type N)":"10 MΩ","Input resistance (Type R)":"10 MΩ","Input resistance (Type S)":"10 MΩ","Input resistance (Type T)":"10 MΩ","Input resistance (type J)":"10 MΩ","Ni 1000 according to GOST":"No","Pt 1000 according to GOST":"No","between S- and MANA (UCM)":"8 V DC","Input resistance (Ni 1000)":"10 MΩ","Input resistance (Pt 1000)":"10 MΩ","With Current Outputs, Max.":"750 Ω","With Voltage Outputs, Min.":"1 kΩ; 0.5 kOhm at 1 to 5 V","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-25 °C; From FS03","For thermocouple measurement":"4","Adjustment of measuring range":"No","Conversion time (per channel)":"0.5 ms","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-25 °C; From FS03","Input resistance (0 to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (1 V to 5 V)":"100 kΩ","Input resistance (LG-Ni 1000)":"10 MΩ","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Analog input with oversampling":"No","Common mode interference, min.":"60 dB","Cycle time (all channels), min.":"3.2 ms; ±0.5 ms, regardless of the number of activated channels","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"100 kΩ","Reference channel of the module":"No","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Between the inputs and MANA (UCM)":"10 V DC","Input resistance (-10 V to +10 V)":"100 kΩ","Input resistance (0 to 6000 ohms)":"10 MΩ","Integration time, parameterizable":"Yes","Internal Temperature Compensation":"Yes","Between The Channels, In Groups Of":"2","Burden of 2-wire transmitter, max.":"820 Ω","Crosstalk between the inputs, max.":"-80 dB","Reparameterization possible in RUN":"Yes","Standardization of measured values":"No","Crosstalk between the outputs, max.":"-100 dB","Input resistance (-2.5 V to +2.5 V)":"10 MΩ","Input resistance (-20 mA to +20 mA)":"25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC","Input resistance (-50 mV to +50 mV)":"10 MΩ","Input resistance (-80 mV to +80 mV)":"10 MΩ","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Current output, no-load voltage, max.":"22 V","Input resistance (-250 mV to +250 mV)":"10 MΩ","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Voltage Output Two-Wire Connection":"Yes","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","PROFINET from GSD version/GSD revision":"V2.3 / -","Power available from the backplane bus":"0.7 W","Current, relative to input range, (+/-)":"0.1 %","For Voltage Output Four-Wire Connection":"Yes","Voltage, relative to input range, (+/-)":"0.1 %","Between the channels and load voltage L+":"Yes","Current, relative to output range, (+/-)":"0.2 %","Time for offset calibration (per module)":"Basic conversion time of the slowest channel","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.2 %","external temperature compensation via RTD":"Yes","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Resistance, relative to input range, (+/-)":"0.1 %","Temperature error of internal compensation":"±6 °C","With Current Outputs, Inductive Load, Max.":"10 mH","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Voltage output, short-circuit current, max.":"24 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Thermocouple, relative to input range, (+/-)":"0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K","Linearity error (relative to input range), (+/-)":"0.02 %","For resistance/resistance thermometer measurement":"2","Linearity error (relative to output range), (+/-)":"0.15 %","Compensation for 0 °C reference point temperature":"Yes; fixed value can be set","Temperature error (relative to input range), (+/-)":"0.005 %/K; With TC type T 0.02 ± % / K","For Resistance Measurement With Two-Wire Connection":"Yes; Only for PTC","Temperature error (relative to output range), (+/-)":"0.002 %/K","Additional Conversion Time For Wire-Break Monitoring":"9 ms","For Resistance Measurement With Four-Wire Connection":"Yes; All measuring ranges except PTC","Resolution with overrange (bit including sign), max.":"16 bit","Additional Conversion Time For Resistance Measurement":"150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms","For Resistance Measurement With Three-Wire Connection":"Yes; All measuring ranges except PTC; internal compensation of the cable resistances","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","Basic conversion time, including integration time (ms)":"9 / 23 / 27 / 107 ms","Resistance thermometer, relative to input range, (+/-)":"0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K","STEP 7 TIA Portal configurable/integrated from version":"V13 / V13.0.2","Constant measurement current for resistance-type transmitter, typ.":"150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"28.8 V","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.02 %","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.02 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$417.83","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c568380d9c08969f0a895aa660157e93.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=417854&mlfb=6ES7534-7QE00-0AB0"},"ai":{"faq":[{"question":"What is 6ES7534-7QE00-0AB0's listed MSI on this component line?","answer":"MSI is listed as Yes on the 6ES7534-7QE00-0AB0 component line."},{"question":"What is 6ES7534-7QE00-0AB0's listed MSO on this component line?","answer":"MSO is listed as Yes on the 6ES7534-7QE00-0AB0 component line."},{"question":"What thermocouple and RTD types does 6ES7534-7QE00-0AB0 read?","answer":"Thermocouple types B, E, J, K, N, R, S, T and RTDs Pt100, Pt200, Pt500, Pt1000 plus Ni100 and Ni1000 (Standard/climate) are supported on 6ES7534-7QE00-0AB0."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7534-7QE00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7534-7QE00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}