{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7547-1JF00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7547-1JF00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7547-1JF00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7547-1JF00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens CM 8xIO-Link, order code 6ES7547-1JF00-0AB0, 8-port IO-Link master for S7-1500, supports V1.0 and V1.1, 1 A per port, 4 A total module current, 24 V DC.","salesMarkdown":"## 8-port IO-Link master for the S7-1500 rack The Siemens 6ES7547-1JF00-0AB0 is an 8-port IO-Link master module that slots directly into an S7-1500 system. It handles both IO-Link V1.0 and V1.1 devices, so you can mix legacy smart sensors with the latest generation on the same module. Each port delivers 1 A, with a total module current of 4 A — enough to power a bank of IO-Link actuators or multi-sensor heads without an external hub. Port type A covers standard IO-Link; port type B adds 24 V DC via an external terminal for loads that need separate power. ## Port power and diagnostics that matter on the line The 1 A per-port rating means you can drive a small valve manifold or a vision sensor directly from the module — no separate power supply needed for each device. The 4 A total cap limits the module to four fully loaded ports or eight lightly loaded ones; plan your device current budget accordingly. Diagnostic alarms are available per port in IO-Link mode only, with short-circuit protection per channel and a wire-break detection flag. The green LED per port shows channel status; red LEDs flag module and channel diagnostics — useful for a field tech walking the cabinet. The module supports I&M data (I&M0 to I&M3) and firmware update via the backplane, so you can push a new FW version without pulling the module. Minimum cycle time is 2 ms — fast enough for most sensor-level IO-Link loops. ## DIN-rail fit and environmental limits The module is 35 mm wide, 147 mm high, and 129 mm deep — it occupies one standard S7-1500 slot width. Vertical installation is rated from -30 °C to 40 °C with derating above that; the 40 °C ceiling means you need airflow or spacing in a densely packed cabinet running warm. Isolation tested at 707 V DC (type test) between channels and the backplane. Reverse polarity protection is built in on the 24 V DC supply. Unshielded cable runs up to 20 m are allowed — enough for most sensor drops inside a machine envelope.","metaTitle":"Siemens 6ES7547-1JF00-0AB0 CM 8xIO-Link, 8-Port, V1.1","metaDescription":"Siemens 6ES7547-1JF00-0AB0 CM 8xIO-Link communication module for S7-1500. 8 ports, IO-Link V1.0/V1.1, 1 A per port, 4 A total.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Communication Modules"],"specifications":{"DI":"Yes","DQ":"No","Depth":"129 mm","Width":"35 mm","title":"6ES7547-1JF00-0AB0","Height":"147 mm","IO-Link":"Yes","I&M data":"Yes; I&M0 to I&M3","Wire-break":"Yes","Group error":"Yes","Port type A":"Yes","Port type B":"Yes; 24 V DC via external terminal","Rated value":"1 A; 4 A total current per module","description":"S7-1500, CM 8xIO-Link, communication module IO-Link Master V1.1; Front connector (screw terminals or push-in) to be ordered separately","Master backup":"Yes","Short-circuit":"Yes","TIO IO-Link IN":"No","Number of ports":"8","TIO IO-Link OUT":"No","lifecycle_stage":"current","Cycle time, min.":"2 ms","Diagnostic alarm":"Yes; The port diagnosis is available in the IO-Link mode only.","Firmware version":"V1.0.2","Rated value (DC)":"24 V","Number of outputs":"8","FW update possible":"Yes","TIO IO-Link IN/OUT":"No","Between The Channels":"No","HW functional status":"FS04","IO-Link protocol 1.0":"Yes","IO-Link protocol 1.1":"Yes","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","For Channel Diagnostics":"Yes; red LED","Short-circuit protection":"Yes; per channel, electronic","Current consumption, max.":"50 mA; without load","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C; Observe derating","Vertical Installation, Min.":"-30 °C","Configuration without S7-PCT":"Yes","Cable length unshielded, max.":"20 m","Horizontal Installation, Max.":"60 °C; Observe derating","Horizontal Installation, Min.":"-30 °C","Monitoring the supply voltage":"Yes","Memory size for device parameter":"2 kbyte; for each port","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Of Which Simultaneously Controllable":"8","Size of process data, input per port":"33 byte; max.","Size of process data, output per port":"32 byte; max.","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"GSD as of Revision 5","PROFINET from GSD version/GSD revision":"GSDML V2.34","Size of process data, input per module":"240 byte; max.","Size of process data, output per module":"240 byte; max.","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"Configurable via GSD file","STEP 7 TIA Portal configurable/integrated from version":"V15.1 with HSP 274"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$407.67 – $1,079.78","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/afd36e9db9763e939ecdeaee6103048b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1343227&mlfb=6ES7547-1JF00-0AB0"},"ai":{"faq":[{"question":"Does 6ES7547-1JF00-0AB0 support IO-Link V1.1?","answer":"Yes, the module supports both IO-Link V1.0 and V1.1 protocols. This means it can communicate with older V1.0 devices and newer V1.1 devices that offer additional data and parameterization features."},{"question":"What is the difference between port type A and port type B on this module?","answer":"Port type A carries standard IO-Link communication and power on the same cable. Port type B adds a separate 24 V DC supply via an external terminal, allowing you to power higher-current loads (like actuators) independently from the IO-Link communication line."},{"question":"What is the maximum cable length for unshielded connections?","answer":"Unshielded cable runs up to 20 m are permitted per port. For longer runs or noisy environments, shielded cable is recommended to maintain signal integrity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7547-1JF00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7547-1JF00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}