{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7924-0CC10-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7924-0CC10-0AA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7924-0CC10-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7924-0CC10-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7 analog terminal block, 3-tier, screw-type, 16-pole IDC, 60 V rated, 1 A rated, 0.5... 2.5 mm² stranded, DIN rail 35 mm / 15 mm, black enclosure, mature lifecycle.","salesMarkdown":"The 6ES7924-0CC10-0AA0 is a 3-tier terminal block designed for analog SIMATIC S7 modules, using screw-type connections on the actuator/sensor side and a 16-pole IDC plug-in connection for the cable side. It mounts on either 35 mm or 15 mm DIN rail, so it fits standard enclosure profiles as well as the narrower rail found in some compact S7 backplane assemblies. The single terminal level per tier keeps wiring tidy for one signal per channel, and the black enclosure with V-0 flammability rating (UL 94 V1) meets the fire-safety requirements for panel-mounted equipment in industrial control cabinets. The 1 A / 60 V rating is the contact limit per terminal point — adequate for 4-20 mA loops, thermocouple signals, RTD inputs, and 0-10 V analog outputs. Operating temperature from 0 to 60 °C keeps it within the ambient limits of a ventilated enclosure; derating is not required within that band. The infeed function means this block can accept the module's supply voltage feed-through — a detail that matters when planning the power distribution for the analog row. No PE connection and no shield connection means the block does not provide a dedicated protective-earth or cable-shield termination point; those must be handled separately on the DIN-rail ground bus or a shielded terminal.","metaTitle":"6ES7924-0CC10-0AA0 Terminal Block, 3-Tier, 60V 1A, DIN Rail","metaDescription":"SIMATIC S7 analog terminal block, 3-tier, screw-type, 16-pole IDC, 60V 1A rated, 0.5-2.5 mm² stranded, DIN rail mount. Mature lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Accessories"],"specifications":{"title":"6ES7924-0CC10-0AA0","Length":"80 mm","Stranded":"0.5 ... 2.5 mm²","Rated Value":"60 V","description":"TERMINAL BLOCK TPA 3-TIER FOR ANALOG SIMATIC S7 MODULES SORT: SCREW TERMINAL WITHOUT LED, PACK. UNIT=1 PCS 16 POLE IDC CONNECT. FOR CABLE","Disconnector":"No","Mounting Type":"DIN rail 35 mm, DIN rail 15 mm","PE connection":"No","lifecycle_stage":"mature","Of The Enclosure":"black","Shield Connection":"No","Insulation Material":"other","Of The Light Source":"without","Current / Rated Value":"1 A","Operating Temperature":"0 ... 60 °C","Width / Of The Enclosure":"68 mm","Number Of Terminal Levels":"1","Position / Of The Terminal":"Top","Required / End Cover Plate":"No","Product Feature / Infeed Function":"Yes","combustibility class acc. to UL 94":"V1","Product Feature / Cross-Connectable":"No","reference code / acc. to IEC 81346-2":"X","Height / With Lowest-Profile Installation":"43.2 mm","Finely Stranded / With Core End Processing":"0.5 ... 2.5 mm²","Finely Stranded / Without Core End Processing":"0.5 ... 2.5 mm²","Number Of Terminal Points / Per Terminal Level":"1","design tested acc. to type of protection / EEx e":"No","Type Of Electrical Connection / For Connecting Cable":"Plug-in connection","Design Of Terminal / Terminal Levels Internally Linked":"No","Type Of Electrical Connection / For Actuators And Sensors":"Screw-type terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$27.43","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6d57f154fff616166253fab8c566f5cb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=502905&mlfb=6ES7924-0CC10-0AA0"},"ai":{"faq":[{"question":"What wire sizes does the 6ES7924-0CC10-0AA0 accept?","answer":"It accepts stranded wire from 0.5 to 2.5 mm², with or without ferrule, on the screw-type terminals. The IDC cable connection accepts the same stranded range."},{"question":"Does this terminal block include a shield connection?","answer":"No. The block has no shield connection and no PE connection. Cable shields must be terminated separately on a DIN-rail ground bus or a dedicated shield terminal."},{"question":"What is the physical size of this terminal block?","answer":"It measures 80 mm in length, 68 mm in width, and 43.2 mm in height with the lowest-profile installation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7924-0CC10-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7924-0CC10-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}