{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2091-4LN10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2091-4LN10","canonicalUrl":"https://aoctrl.com/siemens/6GT2091-4LN10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2091-4LN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF MV plug-in cable, 6GT2091-4LN10, pre-assembled PUR trailing cable, 10 m length, Sub-D (male, 9 pin, 45°) to M12 (female, 8 pin, straight), 300 V rated.","salesMarkdown":"The Siemens 6GT2091-4LN10 is a pre-assembled SIMATIC RF MV plug-in cable, purpose-built to connect an RFID reader to the RF120C communication module. It's a 6-core, shielded, trailing cable, 10 m long, terminated on one end with a Sub-D male 9-pin connector (45° angled) and on the other with an M12 female 8-pin straight connector. The cable designation is L-YC11Y 6x1x0.25 6x24AWG CM, and it's rated for 300 V maximum. The 300 V rating covers the signal and power levels typical on an RFID reader link — no issue for standard 24 VDC sensor supplies, and gives headroom for longer cable runs where voltage drop is a concern. The PUR jacket is resistant to grease and mineral oil, and the braided shield of tin-plated copper keeps RF noise from the reader signal out of the rest of the cabinet. The cable is rated for 3 million bending cycles with a continuous bend radius of 75 mm, which means it's built for moving applications like robot arms or linear slides, not just static tray runs. If you're pulling it through a cable carrier, the minimum single-bend radius is 21.6 mm and multiple-bend minimum is 43 mm — stay above those and the shield integrity holds. ## Regulatory and environmental fit The cable carries EAC approval for Eurasian markets, and the bare cable (without plug) has a UL/ETL listing at 300 V with a CM (Communications) rating, which covers North American plenum and riser installations. The jacket is halogen-free? No — it's PVC (: Halogen-Free: No). It is silicon-free, which matters in paint-shop or adhesive-bonding environments where silicone outgassing can cause adhesion failures. Fire behavior is flame resistant per IEC 60332-1-2, so it passes the vertical flame test for single cables. UV radiation resistant for outdoor exposure, though the black sheath and PUR material already handle that. Temperature range is -30 to +80 °C across storage, transport, operation, and installation — a wide enough window for unheated warehouses or machine-side use.","metaTitle":"Siemens 6GT2091-4LN10 SIMATIC RF MV Plug-in Cable, 10 m, 300","metaDescription":"SIMATIC RF MV plug-in cable, pre-assembled, 10 m, PUR trailing cable, Sub-D to M12, 300 V rated, grease and oil resistant. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2091-4LN10","Maximum":"300 V","To Grease":"resistant","Wire Length":"10 m","description":"SIMATIC RF, MV plug-in cable, pre-assembled, between RF120C and reader, PUR, trailing, length 10 m.","EAC approval":"Yes","Halogen-Free":"No","Silicon-Free":"Yes","Fire Behavior":"flame resistant according to IEC 60332-1-2","During Storage":"-30 ... +80 °C","To Mineral Oil":"resistant","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-30 ... +80 °C","During Transport":"-30 ... +80 °C","Cable Designation":"L-YC11Y 6x1x0.25 6x24AWG CM","Weight Per Length":"45 kg/km","During Installation":"-30 ... +80 °C","Product Description":"Highly flexible communication line (6-core)","Suitability For Use":"Plug-in cable for connecting a reader to the RF120C communication module","Design Of The Shield":"Braided shield made of tin-plated copper wires","Of The Wire Insulation":"PVC","Tensile Load / Maximum":"200 N","With Continuous Bending":"75 mm","Number Of Bending Cycles":"3000000","according to IEC 81346-2":"WG","Number Of Electrical Cores":"6","Type Of Electrical Connection":"Sub-D (male, 9 pin, 45°) / M12 (female, 8 pin, straight)","UL/ETL listing / 300 V Rating":"Yes; CM (only cable without plug)","according to IEC 81346-2:2019":"WGB","Of The Insulation Of Data Wires":"DIN 47100","Number Of Electrical Connections":"2","Insulation Resistance Coefficient":"20 GΩ·m","Loop Resistance Per Length / Maximum":"160 mΩ/m","With Single Bend / Minimum Permissible":"21.6 mm","With Multiple Bends / Minimum Permissible":"43 mm","radiological resistance / to UV radiation":"resistant","Symmetrical Tolerance Of The Outer Diameter / Of Cable Sheath":"0.2 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/304b9129d03b5e7a066f278afea7ecc4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=299236&mlfb=6GT2091-4LN10"},"ai":{"faq":[{"question":"What is the 300 V rating for — is it signal or power?","answer":"The 300 V maximum is the cable's voltage rating, covering both signal and any auxiliary power carried on the reader cable. For a typical 24 VDC RFID reader link, that's well within limits and gives margin for longer runs."},{"question":"Does this cable work with the RF120C module?","answer":"Yes, it's specifically designed as a plug-in cable between an RFID reader and the RF120C communication module. The Sub-D 9-pin male end connects to the module; the M12 8-pin female end connects to the reader."},{"question":"What approvals does it carry for global use?","answer":"It has EAC approval for Eurasian markets and a UL/ETL listing at 300 V with CM rating for the bare cable. It's also flame resistant per IEC 60332-1-2."},{"question":"Can I use this in a cable carrier / drag chain?","answer":"Yes — it's rated for 3 million bending cycles with a continuous bend radius of 75 mm. For a single bend the minimum radius is 21.6 mm; for multiple bends it's 43 mm. The PUR jacket and braided shield handle dynamic flexing well."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2091-4LN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2091-4LN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}