{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2700-6DE03","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2700-6DE03","canonicalUrl":"https://aoctrl.com/siemens/6GT2700-6DE03","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2700-6DE03","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RTLS4060T, ETSI, UWB, phase, 6GT2700-6DE03, IP65, 10-30 VDC, 3.5 W, Bulgin 8-pin.","salesMarkdown":"The 6GT2700-6DE03 is a SIMATIC RTLS4060T transponder from Siemens, part of the RTLS4000 real-time locating system. It uses UWB (ultra-wideband) phase technology for precise indoor positioning, operating in the 2405–2480 MHz and 3100–7000 MHz bands depending on country approvals. The transponder is housed in a light gray (RAL 7035) PC enclosure rated IP65, sized at 151 mm deep, 66 mm wide, and 43 mm high, and mounts via 4 x M5 screws. The IP65 rating means the transponder's housing and optics withstand washdown and dust ingress — suitable for deployment on moving assets in warehouse, logistics, or production environments where exposure to moisture or particulates is expected. The supply voltage range of 10 to 30 VDC at a max power draw of 3.5 W is delivered through an 8-pin Bulgin connector (type PX0410/08S/6065), which also carries two digital inputs (24 V) and one digital output rated for up to 250 mA. This means the transponder can be wired directly into a 24 V industrial control circuit without a separate power supply, and the integrated I/O allows it to trigger or read local signals without a separate I/O block. Range depends on the environment: the transponder is specified for a maximum of 30 m in open air, but that figure extends to 500 m under the same conditions — the manual must be consulted for the applicable range in the actual deployment. The operating temperature range during read/write access is -15 to +50 °C, with the same range applying outside the read/write area and during storage. This limits the transponder to conditioned indoor spaces; it is not rated for freezer or high-heat zones. RTLS transponders like this one are attached to assets, tools, or personnel to provide real-time location data within a facility. The RTLS4000 system with UWB phase technology is designed for applications requiring sub-meter accuracy — tracking work-in-progress on a production line, locating expensive tooling in a warehouse, or monitoring personnel movement in a hazardous zone. The transponder itself stores configuration data in FLASH memory and communicates via the IEEE 802.15.4-2015 UWB HRP PHY protocol. This part carries an NRND (Not Recommended for New Designs) status. Siemens continues to support existing installations.","metaTitle":"Siemens 6GT2700-6DE03 SIMATIC RTLS4060T Transponder, UWB, NR","metaDescription":"Siemens 6GT2700-6DE03 SIMATIC RTLS4060T UWB transponder, ETSI, phase technology, IP65. NRND status. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["RFID & Auto-ID"],"specifications":{"Color":"light gray (RAL 7035)","Depth":"151 mm","Width":"66 mm","title":"6GT2700-6DE03","Height":"43 mm","Typical":"3 m","Material":"PC","Accessories":"Connecting cable with Bulgin plug, 8-pin","description":"SIMATIC RTLS transponder RTLS4060T, ETSI, UWB, phase.","During Storage":"-15 ... +50 °C","Type Of Memory":"FLASH","lifecycle_stage":"mature","Fastening Method":"4 x M5 screws","Property Of Memory":"Configuration memory","Range / 1 / Maximum":"30 m; Range information for open air applications; always follow the manual","Range / 2 / Maximum":"500 m; Range information for open air applications; always follow the manual","protection class IP":"IP65","Type Of Voltage Supply":"Bulgin connector, type PX0410/08S/6065 pin, 8-pin, 10 to 30 Volt, max. 3.5 W","Operating Frequency / 1":"3100 ... 7000 MHz; depending on the country approvals","Operating Frequency / 2":"2405 ... 2480 MHz; depending on the country approvals","During Read/Write Access":"-15 ... +50 °C","Operator Element Version":"8-pin plug type PX0410/08S/6065 for 2 DI (24 V), 1 DO (max. 250 mA), VCC 24 V DC","Suitability For Operation":"RTLS4000 with UWB, phase technology","Outside The Read/Write Area":"-15 ... +50 °C","Product Component / Backup Battery":"No","Protocol / 1 / With Radio Transmission":"IEEE 802.15.4-2015 UWB HRP PHY","Protocol / 2 / With Radio Transmission":"IEEE 802.15.4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9d1193912bdb0125093158bb54ce0519.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1133048&mlfb=6GT2700-6DE03"},"ai":{"faq":[{"question":"What is the supply voltage and connector type?","answer":"The transponder accepts 10 to 30 VDC at a maximum of 3.5 W through an 8-pin Bulgin connector, type PX0410/08S/6065. The same connector also provides two 24 V digital inputs and one digital output rated up to 250 mA."},{"question":"What is the IP rating and what does it mean for deployment?","answer":"IP65. The housing and optics are protected against dust ingress and low-pressure water jets from any direction, making the transponder suitable for washdown environments and outdoor deployment under cover."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2700-6DE03","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2700-6DE03 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-20T14:41:02.429Z","lastPublished":"2026-07-20T14:41:02.429Z","indexable":true}}