{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2810-2AG84-0AX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2810-2AG84-0AX1","canonicalUrl":"https://aoctrl.com/siemens/6GT2810-2AG84-0AX1","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2810-2AG84-0AX1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF682L SmartLabel Nomex, 6GT2810-2AG84-0AX1, UHF RFID tag, 156 x 40 x 0.4 mm, 860-960 MHz, NXP UCODE 7xm-2k, IP67, -40 to +230°C.","salesMarkdown":"The Siemens 6GT2810-2AG84-0AX1 is a SIMATIC RF682L SmartLabel — a UHF RFID tag built on a Nomex paper substrate, sized 156 x 40 x 0.4 mm and beige in color. It operates across the full 860 to 960 MHz UHF band and uses an NXP UCODE 7xm-2k transponder chip with EPCglobal Class 1 Gen 2 / ISO 18000-63 protocol. The tag is IP67 rated, meaning the entire assembly — including the antenna and chip — withstands dust ingress and temporary immersion, so it survives washdown environments in automotive paint shops or industrial laundries. The operating temperature range outside the read/write area spans -40 to +230 °C, with permanent operation up to 85 °C, 6 hours at 200 °C, 1 hour at 220 °C, and short-term peaks to 230 °C. This makes the tag suitable for tracking assets through paint curing ovens or powder-coating lines where standard plastic tags would fail. During read/write access the tag works from -25 to +85 °C, which covers most production-floor environments. The Nomex paper substrate is silicon-free and printable via thermal transfer — critical for paint-shop applications where silicone contamination causes adhesion failure in downstream coating processes. Memory is organized as 96-bit (12-byte) EPC memory expandable to 448-bit (56-byte), plus 2048-bit (256-byte) user memory and 96-bit (12-byte) TID memory. The tag supports lock, unlock, kill, write protection, and password protection on the memory. Maximum transfer rate is 320 kbit/s, and the read range reaches up to 6 m depending on the reader — though the system manual notes overrange is possible and range is reader-dependent. The tag is multitag-capable, so multiple tags can be read in the field simultaneously. It has no backup battery — it's a passive UHF tag powered entirely by the reader's interrogation signal. ## Deployment and mounting The tag can be fastened by gluing or screwing — the 0.4 mm thickness and paper substrate mean it conforms to curved surfaces but is not designed for repeated flexing; torsion and bending stress are only conditionally permissible. It's intended for the SIMATIC RF600 system and is suitable for paint-shop customer versions. The 156 x 40 mm footprint is large enough for custom printing of barcodes or human-readable labels via thermal transfer, which can be applied before or after the tag is mounted.","metaTitle":"Siemens 6GT2810-2AG84-0AX1 SIMATIC RF682L SmartLabel, 860-96","metaDescription":"Siemens SIMATIC RF682L SmartLabel Nomex RFID tag, 156x40x0.4 mm, 860-960 MHz, NXP UCODE 7xm-2k, IP67, -40 to +230°C. Mature lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["RFID & Auto-ID"],"specifications":{"Color":"beige","Depth":"40 mm","IECEx":"No","Width":"156 mm","title":"6GT2810-2AG84-0AX1","Height":"0.4 mm","Material":"Paper","Printable":"Yes","description":"SIMATIC RF682L SmartLabel Nomex, 156x 40x 0.4 mm frequency 860 to 930 MHz NXP UCODE 7xm-2k EPC ID 56 bytes/448 bits user memory 256 byte/2048 bit for assembly custom made printing -40 °C…+200 °C (short term 230 °C) stacked, no core diameter 1,000 units/box 5 boxes/carton 5,000 MOQ suitable for paint shops customer version","Polarization":"Linear","Silicon-Free":"Yes","During Storage":"-40 ... +85 °C","Type Of Memory":"EEPROM","Range / Maximum":"6 m; observe system manual RF600: overrange is possible, range is reader dependent: observe http://support.automation.siemens.com/WW/view/en/67384964","lifecycle_stage":"mature","Fastening Method":"gluing, screwing","Printing Process":"Thermal transfer process","Property Of Memory":"lock, unlock, kill, write protection, password protection","Operating Frequency":"860 ... 960 MHz","protection class IP":"IP67","During Read/Write Access":"-25 ... +85 °C","Suitability For Operation":"RF600","Outside The Read/Write Area":"-40 ... +230 °C","Type Of Memory Organization":"EPC memory 96 bit (12 byte) expandable up to 448 bit (56 byte), user memory 2048 bit (256 byte), TID memory 96 bit (12 byte)","Type Of Transponder Chip Used":"NXP UCODE 7xm-2k","Resistance To Mechanical Stress":"Torsion and bending stress conditionally permissible","Ambient Condition / For Operation":"Operating temperature permanent up to 85 °C, for 6 hours up to 200 °C, for 1 hour up to 220 °C, short-term up to 230 °C","Product Component / Backup Battery":"No","Product Feature / Multitag-Capable":"Yes","Protocol / With Radio Transmission":"EPCglobal Class 1 Gen 2 / ISO 18000-63","Storage Capacity / Of The User Memory":"256 byte","Transfer Rate / With Radio Transmission / Maximum":"320 kbit/s"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1530720&mlfb=6GT2810-2AG84-0AX1"},"ai":{"faq":[{"question":"What temperatures can this tag withstand?","answer":"Outside the read/write area it survives -40 to +230 °C, with permanent operation at 85 °C, 6 hours at 200 °C, 1 hour at 220 °C, and short-term peaks to 230 °C. During read/write access the range is -25 to +85 °C."},{"question":"What protocol and frequency does this tag use?","answer":"It operates at 860 to 960 MHz using EPCglobal Class 1 Gen 2 / ISO 18000-63 protocol, with a maximum transfer rate of 320 kbit/s."},{"question":"Is this tag suitable for paint shop environments?","answer":"Yes, it is specifically suitable for paint-shop customer versions. The Nomex paper substrate is silicon-free, printable via thermal transfer, and withstands the high temperatures of paint curing ovens. The IP67 rating protects against washdown."},{"question":"What memory capacity does this tag have?","answer":"EPC memory is 96 bits (12 bytes) expandable to 448 bits (56 bytes), user memory is 2048 bits (256 bytes), and TID memory is 96 bits (12 bytes). The memory supports lock, unlock, kill, write protection, and password protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2810-2AG84-0AX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2810-2AG84-0AX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}