{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2810-2DC10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2810-2DC10","canonicalUrl":"https://aoctrl.com/siemens/6GT2810-2DC10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2810-2DC10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF640T Tool Tag, 6GT2810-2DC10, on-metal UHF RFID transponder, 902-928 MHz, 50×8 mm, IP68/IPx9K, NXP G2XM, 64-byte user memory.","salesMarkdown":"The Siemens 6GT2810-2DC10 is a SIMATIC RF640T Tool Tag — a compact on-metal UHF RFID transponder built for industrial asset tracking. It operates in the 902 to 928 MHz FCC band using the EPCglobal Class 1 Gen 2 / ISO 18000-63 protocol, with a NXP G2XM chip inside. The 50 mm diameter by 8 mm height form factor mounts directly to metal surfaces using two M4 screws, and the PA12 housing with IP68/IPx9K protection means it survives washdown cycles, coolant spray, and outdoor exposure on a production line. The 4 m read range is the maximum under ideal conditions — actual performance depends on the reader model, antenna placement, and the metal mounting surface. The tag is designed for on-metal use, so it won't detune when screwed onto a steel tool holder or machine body. The 64-byte user memory (512 bit) stores application data like tool ID, calibration date, or maintenance counters alongside the 96-bit EPC, expandable to 240 bits. Operating temperature during read/write is -25 to +85 °C, with storage tolerance from -40 to +125 °C, covering most factory floor conditions including paint ovens and cold storage. ## Integration notes Mounting uses two M4 screws through the tag body — no special bracket needed. The RF600 system manual warns that overrange is possible beyond 4 m, and actual range is reader-dependent.","metaTitle":"Siemens 6GT2810-2DC10 SIMATIC RF640T Tool Tag, 902-928 MHz,","metaDescription":"Siemens SIMATIC RF640T on-metal UHF RFID tag for industrial tool tracking. 902-928 MHz FCC band, 4 m range, IP68/IPx9K, NXP G2XM chip, 64-byte user memory. Active production, cULus","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"MTBF":"1757 a","Color":"anthracite","IECEx":"No","title":"6GT2810-2DC10","Height":"8 mm","Diameter":"50 mm","Material":"PA12","Printable":"No","description":"SIMATIC RF640T Tool Tag; 50x 8 mm (DxH); On-Metal Transponder ISO 18000-6C, EPC Class 1 GEN 2, Frequency 902 to 928 MHz (FCC), Chip type NXP G2XM, EPC 240 bit 64-byte add-on memory, minimum order quantity 10 units.","Polarization":"Linear","Silicon-Free":"Yes","During Storage":"-40 ... +125 °C","Type Of Memory":"EEPROM","cULus approval":"Yes","Range / Maximum":"4 m; observe system manual RF600: overrange is possible, range is reader dependent: observe http://support.automation.siemens.com/WW/view/en/67384964","lifecycle_stage":"mature","Fastening Method":"2 x M4 screws","Shock Resistance":"According to DIN EN 60721-3-7 Class 7 M3","Property Of Memory":"lock, unlock, write protection, password protection","Shock Acceleration":"1000 m/s²","Operating Frequency":"902 ... 928 MHz","protection class IP":"IP68/IPx9K","During Read/Write Access":"-25 ... +85 °C","Vibrational Acceleration":"200 m/s²","Suitability For Operation":"RF600","Outside The Read/Write Area":"-40 ... +125 °C","Type Of Memory Organization":"EPC memory 96 bit (12 byte) assigned with sequential identifier and expandable up to 240 bit (30 byte), user memory 512 bit (64 byte), TID memory 64 bit (8 byte)","Type Of Transponder Chip Used":"NXP G2XM","Product Component / Backup Battery":"No","Product Feature / Multitag-Capable":"Yes","Protocol / With Radio Transmission":"EPCglobal Class 1 Gen 2 / ISO 18000-63","Storage Capacity / Of The User Memory":"64 byte","Transfer Rate / With Radio Transmission / Maximum":"320 kbit/s"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=400306&mlfb=6GT2810-2DC10"},"ai":{"faq":[{"question":"What is the read range of this tag?","answer":"The maximum read range is 4 m, but this is reader-dependent and overrange is possible. Actual performance varies with the specific RF600 reader model, antenna gain, and mounting surface. Test with your hardware before finalizing placement."},{"question":"Can this tag be mounted on metal?","answer":"Yes, it is specifically designed as an on-metal transponder. The PA12 housing and antenna design prevent detuning when mounted directly onto metal surfaces using the two M4 screw holes."},{"question":"What is the memory capacity?","answer":"The tag has 64 bytes (512 bit) of user memory, plus an EPC memory of 96 bits (12 bytes) expandable to 240 bits (30 bytes), and an 8-byte TID memory. The EEPROM supports lock, unlock, write protection, and password protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2810-2DC10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2810-2DC10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}