{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2810-2HC81","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2810-2HC81","canonicalUrl":"https://aoctrl.com/siemens/6GT2810-2HC81","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2810-2HC81","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF620T Container Tag, 6GT2810-2HC81, 127x38x6 mm, IP67, 860-960 MHz, EPC Class 1 Gen 2, IMPINJ MONZA 4QT chip, 64-byte user memory.","salesMarkdown":"The Siemens 6GT2810-2HC81 is a SIMATIC RF620T container tag — a rugged, IP67-rated UHF RFID transponder built for the RF600 reader system. It operates across 860 to 960 MHz (covering global UHF bands) and complies with EPCglobal Class 1 Gen 2 and ISO 18000-63 protocols, so it talks to any standard UHF reader that speaks those protocols. The tag carries an IMPINJ MONZA 4QT chip with 128-bit EPC memory (expandable to 128 bit) and 64 bytes of user memory, plus a 32-bit TID. That user memory is useful for storing lot numbers, maintenance history, or a second identifier alongside the EPC. Read range is listed at up to 8 m, but that's reader-dependent — the system manual (RF600) is the authority for actual performance in your layout. Overrange is possible, so don't treat 8 m as a hard ceiling. Dimensions are 127 mm deep × 38 mm wide × 6 mm tall — a slim, rectangular form factor that mounts via gluing, two M5 screws, or the optional spacer kit. The polypropylene (PP) body in anthracite is laser-engravable for your own asset numbering. IP67 means the tag survives washdown, dust, and temporary immersion — suitable for container tracking, pallet ID, or outdoor asset tagging where moisture and dirt are the norm. Shock resistance meets DIN EN 60721-3-7 Class 7M3 at 1000 m/s², and vibration resistance is 500 m/s², so it holds up on forklift-mounted containers or conveyor pallets. ## Environmental limits and memory handling Read/write temperature range is -25 to +85 °C; outside read/write access it survives -40 to +85 °C. Storage range is -40 to +80 °C. That covers most industrial and outdoor environments short of foundry or cryo. Memory is EEPROM with lock, unlock, write protection, and password protection features. No backup battery — it's passive, powered by the reader field. Multitag-capable, so you can read multiple tags in the field simultaneously. cULus approval is listed, so it's accepted for installations requiring UL recognition in the US and Canada. No IECEx rating — not certified for explosive atmospheres.","metaTitle":"Siemens 6GT2810-2HC81 SIMATIC RF620T Container Tag, 860-960","metaDescription":"Siemens SIMATIC RF620T container tag for RF600 system. 127x38x6 mm, IP67, EPC Class 1 Gen 2, 860-960 MHz, 64-byte user memory. Mature lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["RFID & Auto-ID"],"specifications":{"Color":"anthracite","Depth":"127 mm","IECEx":"No","Width":"38 mm","Height":"6 mm","Material":"PP (polypropylene)","Printable":"Yes","Accessories":"Spacers","Polarization":"Linear","During Storage":"-40 ... +80 °C","Type Of Memory":"EEPROM","cULus approval":"Yes","Range / Maximum":"8 m; observe system manual RF600: overrange is possible, range is reader dependent: observe http://support.automation.siemens.com/WW/view/en/67384964","lifecycle_stage":"mature","Fastening Method":"gluing, 2 x M5 screws, spacer (see accessories)","Printing Process":"Laser inscription","Shock Resistance":"According to DIN EN 60721-3-7 Class 7 M3","Property Of Memory":"lock, unlock, write protection, password protection","Shock Acceleration":"1000 m/s²","Operating Frequency":"860 ... 960 MHz","protection class IP":"IP67","During Read/Write Access":"-25 ... +85 °C","Vibrational Acceleration":"500 m/s²","Suitability For Operation":"RF600","Outside The Read/Write Area":"-40 ... +85 °C","Type Of Memory Organization":"EPC memory 96 bit (12 byte) assigned with sequential identifier and expandable up to 128 bit (16 byte), user memory 512 bit (64 byte), TID memory 32 bit (4 byte)","Type Of Transponder Chip Used":"IMPINJ MONZA 4QT","Resistance To Mechanical Stress":"Torsion and bending stress not permissible","Product Component / Backup Battery":"No","Product Feature / Multitag-Capable":"Yes","Protocol / With Radio Transmission":"EPCglobal Class 1 Gen 2 / ISO 18000-63","Storage Capacity / Of The User Memory":"64 byte","Transfer Rate / With Radio Transmission / Maximum":"320 kbit/s"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=206956&mlfb=6GT2810-2HC81","alternativesUrl":"https://aoctrl.com/api/mcp/products/6GT2810-2HC81/alternatives.json"},"ai":{"faq":[{"question":"What is the read range of this tag?","answer":"The maximum range is listed as 8 m, but this is reader-dependent — the RF600 system manual provides the actual performance for your specific reader and environment. Overrange is possible, so the 8 m figure is a guideline, not a hard limit."},{"question":"What approvals does this tag carry?","answer":"The tag has cULus approval for US and Canada. It does not carry IECEx certification for explosive atmospheres."},{"question":"Can this tag be written to more than once?","answer":"Yes, the EEPROM memory supports multiple read/write cycles with lock, unlock, write protection, and password protection features. The user memory (64 bytes) can be rewritten as needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2810-2HC81","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2810-2HC81 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}