{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2810-2HF10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2810-2HF10","canonicalUrl":"https://aoctrl.com/siemens/6GT2810-2HF10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2810-2HF10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF671T (FCC) RFID transponder, 902-928 MHz, ISO 18000-63 / EPC Class 1 Gen 2, 128-bit EPC, 32-bit user memory, -40 to +175°C, IP67, glue-on metal mount.","salesMarkdown":"The Siemens 6GT2810-2HF10 is a SIMATIC RF671T UHF RFID transponder from the RF67xT family, designed for passive identification in harsh industrial environments. It operates on the FCC frequency band of 902 to 928 MHz and complies with ISO 18000-63 and EPC Class 1 Gen 2 standards. The tag carries an Impinj Monza R6-P chip with 128 bits (16 bytes) of EPC memory and 32 bits (4 bytes) of user memory. This is the version intended for gluing onto metal surfaces — the FR4 package measures 10 x 5 x 3 mm and is rated IP67, meaning the tag body and antenna survive washdown and particulate ingress. ## Signal integrity and mounting reality The tag is designed for direct metal mounting — the FR4 substrate and antenna tuning account for the detuning effect of a metal surface, so you don't need a spacer or foam pad. Glue it with a high-temperature epoxy rated above 175 °C; cyanoacrylate will outgas and fail in the first heat cycle. Heat-resistant printing is not possible on this variant, so label the carton, not the tag. At 902-928 MHz, read range depends on the reader antenna gain and local RF environment. Expect reliable reads inside a 2-4 meter zone with a 6 dBi circular-polarized antenna in a clean plant. Metal behind the tag is fine; liquid or foil-lined containers in the read path will kill the signal — it's noise till proven otherwise, so test the read point with a handheld before committing the conveyor layout.","metaTitle":"Siemens 6GT2810-2HF10 SIMATIC RF671T RFID Tag, 902-928 MHz,","metaDescription":"Siemens SIMATIC RF671T RFID transponder, FCC variant. ISO 18000-63, EPC Class 1 Gen 2. 902-928 MHz, -40 to +175°C, IP67. Active production, RoHS compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2810-2HF10","Group Code":"R322","description":"SIMATIC RF671T (FCC) FR4 10 x 5 x 3 mm ISO 18000-63, EPC Class 1 Gen 2 frequency 902 to 928 MHz IMPINJ MONZA R6-P 128 bits (16 bytes) EPC ID 32 bits (4 bytes) user memory fixing by glueing on metal, heat-resistant printing not possible temperature from -40 °C to +175 °C IP67 50 units/carton 1 carton 50 units MOQ","Product Group":"4372","Product class":"A: Standard product which is a stock item could be returned within the returns guidelines/period.","Quantity Unit":"1 Piece","Product Family":"RF67xT","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : EAR99H","Packaging dimensions (L x W x H)":"1.00 x 1.00 x 1.00 mm","Compliance with the substance restrictions according to RoHS directive":"Given","REACH Art. 33 Duty to inform according to the current list of candidates":"Reach Information"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1b1aa8887c3b9ab64c403b21de4c99f8.pdf","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6GT2810-2HF10?tree=CatalogTree"},"ai":{"faq":[{"question":"What compliance documentation is available for this tag?","answer":"RoHS compliance is confirmed per the substance restrictions. REACH Article 33 duty-to-inform applies based on the current candidate list. Export control is AL: N / ECCN: EAR99H."},{"question":"What is the group code and product group for this part?","answer":"Group Code R322, Product Group 4372. These are Siemens internal classification codes used for catalog and ERP filtering."},{"question":"Can this tag be read through plastic or fiberglass?","answer":"Yes, the 902-928 MHz UHF signal penetrates non-metallic, non-liquid materials. The tag is optimized for metal mounting, so reading through a plastic housing or fiberglass panel is within normal operation. Test with your specific material stack-up — liquid or carbon-fiber content will attenuate the signal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2810-2HF10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2810-2HF10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}