{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2815-0BH30","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2815-0BH30","canonicalUrl":"https://aoctrl.com/siemens/6GT2815-0BH30","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2815-0BH30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF600 connecting cable antenna L3 pre-assembled, 50 Ω, LMR-195, R-TNC (female, straight) both ends, 3 m, IP65, PE dielectric, CMR/FT4 flame-resistant, black sheath.","salesMarkdown":"The Siemens 6GT2815-0BH30 is a pre-assembled coaxial cable in the SIMATIC RF600 family, purpose-built for connecting a UHF antenna to an RF600 reader. It comes terminated with R-TNC (female, straight) connectors on both ends, so it is a drop-in link between the reader port and the antenna — no field termination needed. The cable is 3 m long, has a characteristic impedance of 50 Ω, and is rated for a maximum voltage of 1000 V. The sheath is black, the dielectric is PE, and the cable designation is LMR-195. This is a sealed assembly rated IP65, so it handles washdown environments and outdoor exposure on the antenna side of an RFID portal. The braided shield is tin-plated copper, giving good EMI rejection over the 3 m run. At 900 MHz the attenuation is 0.365 dB/m, meaning about 1.1 dB total loss across the full length — acceptable for most UHF read ranges. The 1000 V maximum rating is the dielectric withstand of the cable itself, not the operating voltage of the RFID system (which is usually well under 50 V). It means the cable can coexist in a tray with higher-voltage power cables without breakdown risk, as long as the jacket is intact. Fire behavior is flame-resistant per UL/NEC and CSA CMR / FT4 (applies to the cable only, not the plug). That qualifies it for plenum and riser runs in commercial buildings — a common requirement when the cable passes through air-handling spaces. Minimum bend radius is 12.7 mm for a single bend and 50.8 mm for repeated flexing. That is tight enough to route through standard cable trays and around reader enclosures, but repeated sharp kinks will degrade the impedance match. Radiological resistance to UV radiation is listed as resistant, so the sheath holds up in direct sunlight — important for outdoor antenna mounts.","metaTitle":"Siemens 6GT2815-0BH30 SIMATIC RF600 Coaxial Cable, 3 m, 50 Ω","metaDescription":"Siemens 6GT2815-0BH30 SIMATIC RF600 pre-assembled coaxial cable, 3 m, 50 Ω, 1000 V max, LMR-195, R-TNC connectors, IP65, CMR/FT4 rated. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2815-0BH30","Maximum":"1000 V","Rated Value":"50 Ω","Wire Length":"3 m","description":"SIMATIC RF600 connecting cable antenna L3 pre-assembled, between reader and antenna, IP65, PE, CMR/MPR, length 3 m.","Halogen-Free":"No","Fire Behavior":"Flame-resistant acc. to UL/NEC, CSA: CMR, FT4 (only cable without plug)","Of Dielectric":"PE","During Storage":"-70 ... +85 °C","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-40 ... +85 °C","During Transport":"-40 ... +85 °C","Cable Designation":"LMR-195","Weight Per Length":"30 kg/km","Of Inner Conductor":"Cu","During Installation":"-40 ... +80 °C","Product Description":"Coaxial cable","Suitability For Use":"Plug-in cable for connecting a UHF antenna to an RF600 reader","Design Of The Shield":"Braided shield made of tin-plated copper wires","at 900 MHz / maximum":"0.365 dB/m","Tensile Load / Maximum":"180 N","according to IEC 81346-2":"WG","Type Of Electrical Connection":"R-TNC (female, straight) / R-TNC (female, straight)","according to IEC 81346-2:2019":"WGB","Number Of Electrical Connections":"2","Loop Resistance Per Length / Maximum":"41 mΩ/m","With Single Bend / Minimum Permissible":"12.7 mm","With Multiple Bends / Minimum Permissible":"50.8 mm","radiological resistance / to UV radiation":"resistant"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=48766&mlfb=6GT2815-0BH30"},"ai":{"faq":[{"question":"What is the maximum voltage rating of this cable?","answer":"The maximum voltage is 1000 V. This is the dielectric withstand rating of the coaxial cable, not the RFID system operating voltage."},{"question":"What is the characteristic impedance of this cable?","answer":"The rated impedance is 50 Ω, matching standard UHF antenna and reader ports."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2815-0BH30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2815-0BH30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}