{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2815-0BN10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2815-0BN10","canonicalUrl":"https://aoctrl.com/siemens/6GT2815-0BN10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2815-0BN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF600 connecting cable, coaxial, LMR-195, 10 m, 50 Ω, pre-assembled R-TNC (female) both ends, IP65, PE dielectric, CMR/FT4 flame rated.","salesMarkdown":"The Siemens 6GT2815-0BN10 is a pre-assembled coaxial cable from the SIMATIC RF600 family, designed as a plug-in connection between an RF600 reader and a UHF antenna. It carries a characteristic impedance of 50 Ω, which is the standard for UHF RFID antenna feeds — mismatching this value introduces return loss and reduces read range. The cable is terminated with R-TNC (female, straight) connectors on both ends, so it drops directly into the reader and antenna ports without field termination. Maximum voltage rating is 1000 V, which is the insulation rating of the cable and connectors. Attenuation is specified at 0.365 dB/m at 900 MHz, which is the center of the UHF RFID band (860–960 MHz). Over the 10 m length, that works out to roughly 3.65 dB of loss — about half the power is dissipated in the cable. For a typical reader output of 30 dBm, the antenna sees about 26.35 dBm. If your installation requires a longer cable run, factor this loss into the link budget; the reader's output power may need adjustment to stay within regulatory limits. The cable is designated LMR-195, a low-loss 50 Ω coaxial cable with a solid copper inner conductor and a braided shield of tin-plated copper wires. The minimum bend radius with a single bend is 12.7 mm; with repeated flexing, keep bends above 50.8 mm to avoid work-hardening the braid. Flame rating is CMR (Communications Riser) per UL/NEC and FT4 per CSA, but only for the cable without the plug — the assembled connectors may have a different listing. For plenum-rated installations, verify the connector's own flame rating separately.","metaTitle":"Siemens 6GT2815-0BN10 SIMATIC RF600 Coaxial Cable, 10 m, 50","metaDescription":"Siemens 6GT2815-0BN10 SIMATIC RF600 coaxial cable, 10 m, 50 Ω, pre-assembled R-TNC connectors, IP65, CMR/FT4 flame rating. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2815-0BN10","Maximum":"1000 V","Rated Value":"50 Ω","Wire Length":"10 m","description":"SIMATIC RF600 connecting cable antenna L10 pre-assembled, between reader and antenna, IP65, PE, CMR/MPR, length 10 m.","Halogen-Free":"No","Fire Behavior":"Flame-resistant acc. to UL/NEC, CSA: CMR, FT4 (only cable without plug)","Of Dielectric":"PE","During Storage":"-70 ... +85 °C","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-40 ... +85 °C","During Transport":"-40 ... +85 °C","Cable Designation":"LMR-195","Weight Per Length":"30 kg/km","Of Inner Conductor":"Cu","During Installation":"-40 ... +80 °C","Product Description":"Coaxial cable","Suitability For Use":"Plug-in cable for connecting a UHF antenna to an RF600 reader","Design Of The Shield":"Braided shield made of tin-plated copper wires","at 900 MHz / maximum":"0.365 dB/m","Tensile Load / Maximum":"180 N","according to IEC 81346-2":"WG","Type Of Electrical Connection":"R-TNC (female, straight) / R-TNC (female, straight)","according to IEC 81346-2:2019":"WGB","Number Of Electrical Connections":"2","Loop Resistance Per Length / Maximum":"41 mΩ/m","With Single Bend / Minimum Permissible":"12.7 mm","With Multiple Bends / Minimum Permissible":"50.8 mm","radiological resistance / to UV radiation":"resistant"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$81.28","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=32294&mlfb=6GT2815-0BN10"},"ai":{"faq":[{"question":"What is the maximum voltage rating?","answer":"The cable assembly is rated for a maximum voltage of 1000 V. This is the insulation rating, not the RFID system operating voltage."},{"question":"What is the characteristic impedance?","answer":"50 Ω, which is the standard impedance for UHF antenna feeds. Using a cable with a different impedance will cause mismatch loss."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2815-0BN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2815-0BN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}