{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2815-0BN40","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2815-0BN40","canonicalUrl":"https://aoctrl.com/siemens/6GT2815-0BN40","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2815-0BN40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF600 connecting cable, LMR-400-FR LSZH UL, pre-assembled 40 m, 50 Ω, 2000 V maximum, halogen-free, CMR/FT4 rated.","salesMarkdown":"The Siemens 6GT2815-0BN40 is a pre-assembled coaxial cable for the SIMATIC RF600 system, purpose-built to connect a UHF antenna to an RF600 reader. It comes terminated with R-TNC (female, straight) connectors on both ends, so it's a drop-in replacement for a 40 m run — no field termination needed. Rated at 50 Ω characteristic impedance, which matches the standard for UHF RFID antenna systems — mismatched impedance would cause reflections and reduce read range. The maximum voltage rating of 2000 V is the cable's dielectric withstand, not an operating voltage; the actual RF signal is low-voltage, but this rating tells you the insulation can handle transient surges on long outdoor runs. Attenuation is specified at 0.13 dB/m at 900 MHz, so over the full 40 m length you lose about 5.2 dB. That's within the link budget of most UHF readers, but if you're pushing the edge of read range, factor that loss into your system gain calculation. The cable is halogen-free and carries a flame-resistant rating of CMR (UL/NEC) and FT4 (CSA) — that's riser-rated for plenum and vertical shaft installations where smoke toxicity matters. The designation LMR-400-FR LSZH UL confirms it's a low-smoke zero-halogen variant of the LMR-400 class, so it's suitable for indoor cable trays and enclosed spaces where code demands low-halogen cabling. This cable is part of the SIMATIC RF600 UHF RFID system, used in logistics, warehousing, and production lines for identifying pallets, totes, and work-in-progress. The 40 m length is typical for connecting a reader cabinet to an antenna mounted on a gantry or dock door — long enough to route through cable trays but short enough to keep RF loss manageable.","metaTitle":"Siemens 6GT2815-0BN40 SIMATIC RF600 Coaxial Cable, 40 m, 50","metaDescription":"SIMATIC RF600 connecting cable, LMR-400-FR LSZH UL, 40 m, 50 Ω, 2000 V max, halogen-free, CMR/FT4 rated. Active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2815-0BN40","Maximum":"2000 V","Rated Value":"50 Ω","Wire Length":"40 m","description":"SIMATIC RF600 connecting cable for antenna L40 pre-assembled, between reader and antenna, IP65 PE, CMR/MPR, Length 40 m damping.","Halogen-Free":"Yes","Fire Behavior":"Flame-resistant acc. to UL/NEC, CSA: CMR, FT4 (only cable without plug)","Of Dielectric":"PE","During Storage":"-70 ... +85 °C","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-40 ... +85 °C","During Transport":"-40 ... +85 °C","Cable Designation":"LMR-400-FR LSZH UL","Weight Per Length":"133 kg/km","Of Inner Conductor":"Cu","During Installation":"-40 ... +80 °C","Product Description":"Coaxial cable","Suitability For Use":"Plug-in cable for connecting a UHF antenna to an RF600 reader","Design Of The Shield":"Braided shield made of tin-plated copper wires","at 900 MHz / maximum":"0.13 dB/m","according to IEC 81346-2":"WG","Type Of Electrical Connection":"R-TNC (female, straight) / R-TNC (female, straight)","according to IEC 81346-2:2019":"WGB","Number Of Electrical Connections":"2","Loop Resistance Per Length / Maximum":"14.3 mΩ/m","With Single Bend / Minimum Permissible":"50 mm","radiological resistance / to UV radiation":"resistant"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=249115&mlfb=6GT2815-0BN40"},"ai":{"faq":[{"question":"What is the maximum voltage rating?","answer":"The cable is rated for a maximum of 2000 V, which is the dielectric withstand voltage of the insulation."},{"question":"What is the characteristic impedance?","answer":"It is rated at 50 Ω, matching standard UHF antenna and reader impedance."},{"question":"What compliance documentation is available?","answer":"The cable is halogen-free and flame-resistant per UL/NEC (CMR) and CSA (FT4). It is a low-smoke zero-halogen (LSZH) design."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2815-0BN40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2815-0BN40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}