{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2815-1BN10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2815-1BN10","canonicalUrl":"https://aoctrl.com/siemens/6GT2815-1BN10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2815-1BN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF600 connecting cable, pre-assembled, 10 m, 50 Ω, R-TNC (female, straight) both ends, IP65, black PE sheath, flame-resistant CMR/FT4.","salesMarkdown":"The Siemens 6GT2815-1BN10 is a pre-assembled coaxial cable for connecting a UHF antenna to an RF600 reader in an RFID installation. It is a fixed-length assembly, 10 m, with a characteristic impedance of 50 Ω — the standard for RF reader-to-antenna links in the 860–960 MHz UHF band. The cable is designated LMR-300, a low-loss 50 Ω coax with a solid copper inner conductor and a braided shield of tin-plated copper wires. Both ends terminate with R-TNC (female, straight) connectors. That connector type is common on Siemens RF600 readers and antennas — it mates directly without adapters. The maximum voltage rating is 2000 V — that is the peak voltage the cable dielectric (PE) can withstand before breakdown, not the operating voltage. In practice, the RF signal on this cable is a few volts peak-to-peak; the 2000 V rating is a safety margin for transient or installation-phase faults. Attenuation at 900 MHz is 0.199 dB/m. Over the 10 m length that adds up to roughly 2 dB of signal loss — acceptable for typical reader-to-antenna distances in a warehouse or production line. If the run needs to be longer, a lower-loss cable (e.g., LMR-400) would be needed, but that changes the connector and impedance matching. The cable is flame-resistant per UL/NEC and CSA CMR/FT4 (only the cable without the plug). CMR (Communications Riser) and FT4 (Flame Test) ratings mean it can be run through vertical shafts and plenum spaces in commercial buildings without special conduit — a common requirement for RFID installations above drop ceilings or between floors.","metaTitle":"Siemens 6GT2815-1BN10 SIMATIC RF600 Coaxial Cable, 10 m, 50","metaDescription":"Siemens 6GT2815-1BN10 SIMATIC RF600 connecting cable, 10 m, 50 Ω, R-TNC connectors, IP65, flame-resistant CMR/FT4. Active production. RFQ for sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2815-1BN10","Maximum":"2000 V","Rated Value":"50 Ω","Wire Length":"10 m","description":"SIMATIC RF600 connecting cable for antenna L10; damping 2 DB; pre-assembled; IP65; PE, CMR/MPR, length 10 m.","Halogen-Free":"No","Fire Behavior":"Flame-resistant acc. to UL/NEC, CSA: CMR, FT4 (only cable without plug)","Of Dielectric":"PE","During Storage":"-70 ... +85 °C","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-40 ... +85 °C","During Transport":"-40 ... +85 °C","Cable Designation":"LMR-300","Weight Per Length":"80 kg/km","Of Inner Conductor":"Cu","During Installation":"-40 ... +80 °C","Product Description":"Coaxial cable","Suitability For Use":"Plug-in cable for connecting a UHF antenna to an RF600 reader","Design Of The Shield":"Braided shield made of tin-plated copper wires","at 900 MHz / maximum":"0.199 dB/m","Tensile Load / Maximum":"535 N","according to IEC 81346-2":"WG","Type Of Electrical Connection":"R-TNC (female, straight) / R-TNC (female, straight)","according to IEC 81346-2:2019":"WGB","Number Of Electrical Connections":"2","Loop Resistance Per Length / Maximum":"14.3 mΩ/m","With Single Bend / Minimum Permissible":"22.2 mm","With Multiple Bends / Minimum Permissible":"76.2 mm","radiological resistance / to UV radiation":"resistant"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a3d64187c8340c6fc0e41a6af16bd2fc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=188895&mlfb=6GT2815-1BN10"},"ai":{"faq":[{"question":"What is the maximum voltage rating?","answer":"The maximum voltage rating is 2000 V, which is the peak dielectric withstand voltage of the PE insulation."},{"question":"What is the characteristic impedance?","answer":"The characteristic impedance is 50 Ω, standard for UHF RFID antenna connections."},{"question":"What compliance certifications does it carry?","answer":"The cable (without plug) is flame-resistant according to UL/NEC and CSA: CMR, FT4. The cable sheath is PE and is resistant to UV radiation. Halogen-free is not specified."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2815-1BN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2815-1BN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}