{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2891-4FN10","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2891-4FN10","canonicalUrl":"https://aoctrl.com/siemens/6GT2891-4FN10","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2891-4FN10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF, MV plug-in cable, pre-assembled, 6-core, 10 m, M12 8-pin male/female, 300 V, UL CM, trailing.","salesMarkdown":"The Siemens 6GT2891-4FN10 is a pre-assembled, highly flexible communication cable for the SIMATIC RF identification system. It connects an RFID reader to a communication module like the ASM 456, RF160C, RF170C, or RF18XC, or serves as an extension between them. The cable is 10 m long, terminated with an M12 8-pin male connector on one end and an M12 8-pin female connector on the other, so it plugs straight in without field wiring. Rated for a maximum of 300 V, this cable handles the signal and low-power supply voltages typical in RFID reader circuits without derating concerns. The 300 V rating is the UL/ETL listing for the cable itself (CM rated), meaning it passes the vertical-tray flame test for general building use — a standard requirement for plenum-adjacent runs in North American installations. The cable is designed for continuous flexing applications: it withstands 3,000,000 bending cycles with a minimum bend radius of 75 mm under continuous flex, and can take a single bend as tight as 21.6 mm. This makes it suitable for dynamic applications like cable carriers on moving gantries or robot arms, not just static panel-to-reader drops. It is resistant to grease, mineral oil, and UV radiation, and is silicon-free — important for paint-shop or adhesive-application environments where silicone contamination causes surface defects. The cable is not halogen-free, so it is not the first choice for enclosed public spaces with strict smoke-toxicity requirements. ## Construction and mechanical limits The cable uses a braided shield of tin-plated copper wires, giving good EMI rejection for the sensitive reader-to-modem link. The 6-core construction (6x1x0.25 mm² / 6x24 AWG) follows the L-YC11Y designation with PVC insulation per DIN 47100 color coding. Maximum tensile load is 200 N, so it can be pulled through cable trays but should not be used as a load-bearing line. Loop resistance is 160 mΩ/m maximum, and insulation resistance is 20 GΩ·m — both figures confirm the cable can carry the 24 VDC supply and RS-232/422 signals over the full 10 m without excessive drop or leakage.","metaTitle":"Siemens 6GT2891-4FN10 SIMATIC RF MV Plug-in Cable, 10 m, 300","metaDescription":"Siemens 6GT2891-4FN10 SIMATIC RF MV plug-in cable, 10 m length, 300 V rated, M12 8-pin connectors, UL CM rated. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"title":"6GT2891-4FN10","Maximum":"300 V","To Grease":"resistant","Wire Length":"10 m","description":"SIMATIC RF, MV plug-in cable, pre-assembled, between ASM 456, RF160C, RF170C, RF18XC and reader, or extension cable for ASM 456, RF160C, RF170C, RF18XC with RF, MV, MOBY PUR, trailing, length 10 m.","EAC approval":"Yes","Halogen-Free":"No","Silicon-Free":"Yes","Fire Behavior":"flame resistant according to IEC 60332-1-2","During Storage":"-30 ... +80 °C","To Mineral Oil":"resistant","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-30 ... +80 °C","During Transport":"-30 ... +80 °C","Cable Designation":"L-YC11Y 6x1x0.25 6x24AWG CM","Weight Per Length":"45 kg/km","During Installation":"-30 ... +80 °C","Product Description":"Highly flexible communication line (6-core)","Suitability For Use":"Plug-in or extension cable for connecting a reader to a communication module","Design Of The Shield":"Braided shield made of tin-plated copper wires","Of The Wire Insulation":"PVC","Tensile Load / Maximum":"200 N","With Continuous Bending":"75 mm","Number Of Bending Cycles":"3000000","according to IEC 81346-2":"WG","Number Of Electrical Cores":"6","Type Of Electrical Connection":"M12 (male, 8 pin, straight) / M12 (female, 8 pin, straight)","UL/ETL listing / 300 V Rating":"Yes; CM (only cable without plug)","according to IEC 81346-2:2019":"WGB","Of The Insulation Of Data Wires":"DIN 47100","Number Of Electrical Connections":"2","Insulation Resistance Coefficient":"20 GΩ·m","Loop Resistance Per Length / Maximum":"160 mΩ/m","With Single Bend / Minimum Permissible":"21.6 mm","With Multiple Bends / Minimum Permissible":"43 mm","radiological resistance / to UV radiation":"resistant","Symmetrical Tolerance Of The Outer Diameter / Of Cable Sheath":"0.2 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$53.34","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a9ed0c9997ea1d5bd94ec749264949a1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=105347&mlfb=6GT2891-4FN10"},"ai":{"faq":[{"question":"What is the maximum voltage rating?","answer":"The cable is rated for a maximum of 300 V, with a UL/ETL listing confirming the CM flame-rating for the cable itself (without plug)."},{"question":"What approvals does this cable carry?","answer":"It carries EAC approval for the Eurasian Customs Union, and UL/ETL listing for 300 V with a CM (Communications) fire rating per the National Electrical Code. The cable is also flame-resistant according to IEC 60332-1-2."},{"question":"What is the cable's resistance to chemicals and environmental factors?","answer":"The cable is resistant to grease, mineral oil, and UV radiation. It is silicon-free, making it suitable for paint and adhesive environments, but it is not halogen-free."},{"question":"What is the minimum bend radius for continuous flexing?","answer":"For continuous bending, the minimum permissible bend radius is 75 mm. For a single bend it can go as tight as 21.6 mm, and for multiple bends 43 mm. It is rated for 3,000,000 bending cycles."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2891-4FN10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2891-4FN10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}