{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6GT2891-4MH50","brand":"Siemens","brandSlug":"siemens","productSlug":"6GT2891-4MH50","canonicalUrl":"https://aoctrl.com/siemens/6GT2891-4MH50","factsUrl":"https://aoctrl.com/api/mcp/products/6GT2891-4MH50","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC RF IO-Link connecting cable, pre-assembled, M12 4-pin male to female, 3-core PUR, 5 m length, 30 V maximum.","salesMarkdown":"The Siemens 6GT2891-4MH50 is a pre-assembled IO-Link connecting cable from the SIMATIC RF family, purpose-built to link an IO-Link device (like an RFID reader) to an IO-Link master. Both ends terminate in M12 4-pin straight connectors — male on one side, female on the other — so it plugs directly between the sensor and the master without field wiring. The cable runs 5 m fixed length, unshielded, with three cores (brown, white, blue, black wire insulation) in a black PVC jacket. The 30 V maximum rating matches the standard IO-Link voltage range, so it handles the 24 V DC supply and data line common in IO-Link v1.1 systems. The 30 V maximum is the voltage ceiling for the cable assembly — IO-Link masters typically output 24 V DC, so this is comfortably above the working voltage. The 5 m length is the fixed pre-assembled run; if your panel layout needs a longer or shorter drop, this exact order code won't stretch or trim. The jacket carries flame-resistant ratings per AWM STYLE 21317: VW-1 for USA applications and FT-1 for Canada, both at 80 °C. That means the cable passes vertical flame testing for use inside control cabinets or cable trays where flammability compliance matters. It is not halogen-free, so if your spec requires zero-halogen for smoke density in occupied spaces, this isn't the cable for that job. Minimum bend radius with a single bend is 34.4 mm; with multiple bends it's 64.5 mm. That's tight enough for routing inside a junction box or along a DIN-rail channel, but the symmetrical outer diameter tolerance of 0.15 mm means the jacket thickness is consistent — no bulges that snag during pull-through. This cable sits between an IO-Link master (typically a SIMATIC RF120C or similar) and an IO-Link-capable reader or sensor. The M12 4-pin connectors are standard for IO-Link — pin 1 is 24 V, pin 3 is 0 V, pin 4 is the data line (C/Q). The straight form factor means it works best where both ports face the same direction; if you need a right-angle exit to save space, you'd look for a different cable variant. The cable is designated LiY-11Y 4xAWG 22/19, which is a PVC-insulated, unshielded data cable with 22 AWG stranded conductors. Loop resistance per meter is 108 mΩ/m maximum, so at 5 m the total loop resistance is about 0.54 Ω — negligible for IO-Link's 24 V supply, but worth noting if you're daisy-chaining power through multiple cables.","metaTitle":"Siemens 6GT2891-4MH50 SIMATIC RF IO-Link Cable, 5 m, 30 V","metaDescription":"Siemens 6GT2891-4MH50 SIMATIC RF IO-Link connecting cable, pre-assembled, M12 4-pin both ends, 3-core PUR, 5 m length, 30 V max. Active production. Flame-resistant jacket.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["RFID & Auto-ID"],"specifications":{"Maximum":"30 V","Wire Length":"5 m","Halogen-Free":"No","Fire Behavior":"flame resistant according to AWM STYLE 21317 80°C 30V VW-1 for USA and AWM I/II A/B 80°C 30V FT-1 for Canada","During Storage":"-40 ... +80 °C","Of Cable Sheath":"Black","lifecycle_stage":"mature","During Operation":"-5 ... +80 °C","During Transport":"-40 ... +80 °C","Cable Designation":"LiY-11Y 4xAWG 22/19","During Installation":"-5 ... +80 °C","Product Description":"Sensor cable (3-core)","Suitability For Use":"Plug-in cable for connecting an IO-Link device to an IO-Link master","Design Of The Shield":"unshielded","Of The Wire Insulation":"PVC","according to IEC 81346-2":"WG","Number Of Electrical Cores":"3","Type Of Electrical Connection":"M12 (male, 4 pin, straight) / M12 (female, 4 pin, straight)","according to IEC 81346-2:2019":"WGB","Of The Insulation Of Data Wires":"brown, white, blue, black","Number Of Electrical Connections":"2","Insulation Resistance Coefficient":"20 GΩ·m","Loop Resistance Per Length / Maximum":"108 mΩ/m","With Single Bend / Minimum Permissible":"34.4 mm","With Multiple Bends / Minimum Permissible":"64.5 mm","Symmetrical Tolerance Of The Outer Diameter / Of Cable Sheath":"0.15 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9f69370122d6bf0237ae8ec3b63b318b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=519624&mlfb=6GT2891-4MH50","alternativesUrl":"https://aoctrl.com/api/mcp/products/6GT2891-4MH50/alternatives.json"},"ai":{"faq":[{"question":"What is the maximum voltage rating?","answer":"The cable assembly is rated for a maximum of 30 V, which covers the standard 24 V DC supply used in IO-Link systems."},{"question":"What is the cable length?","answer":"The pre-assembled cable is 5 m long, fixed — not a cut-to-length spool."},{"question":"What connectors does it use?","answer":"Both ends are M12 4-pin straight connectors: male on one end, female on the other. Pinout follows the standard IO-Link assignment."},{"question":"Is the cable shielded?","answer":"No, it is unshielded. For environments with high EMI, you would need a shielded variant."},{"question":"What fire rating does the jacket carry?","answer":"The jacket is flame-resistant per AWM STYLE 21317: VW-1 for the US market and FT-1 for Canada, rated at 80 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6GT2891-4MH50","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6GT2891-4MH50 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}