{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3210-1PC31-6UL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3210-1PC31-6UL0","canonicalUrl":"https://aoctrl.com/siemens/6SL3210-1PC31-6UL0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3210-1PC31-6UL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120 Power Module PM240-2, unfiltered with built-in braking chopper, 3-phase 200-240 V AC, 37 kW high overload, IP20, blocksize format.","salesMarkdown":"## Duty ratings that set the operating envelope The 6SL3210-1PC31-6UL0 is a SINAMICS G120 Power Module PM240-2 in the air-cooled blocksize format, rated for 3-phase 200-240 V AC input. For high-overload (HO) duty it delivers 37 kW continuous output, with 200 % overload for 3 seconds, 150 % for 57 seconds, and 100 % for 240 seconds — this profile suits applications like conveyors or extruders that need short torque bursts without oversizing the drive. Under low-overload (LO) duty the continuous rating rises to 45 kW, with 150 % for 3 seconds, 110 % for 57 seconds, and 100 % for 240 seconds. The HO ambient ceiling is 50 °C; LO derates to 40 °C ambient — a meaningful difference if the panel runs warm. ## Built-in braking chopper and unfiltered topology An integrated braking chopper handles DC-bus overvoltage during deceleration, so an external braking resistor can be added without a separate chopper module. The unfiltered design means the drive outputs PWM voltage with full dV/dt — motor cable runs beyond 25 meters may need an output reactor or dV/dt filter to protect the motor winding insulation. The module ships without a control unit or operator panel; it accepts any CU from the SINAMICS G120 family (CU240E-2, CU250S-2, etc.) and is approved for CU firmware version V4.7 HF8 and later. The blocksize footprint measures 708 x 305 x 357 mm (HxWxD) with IP20 protection — plan for top and bottom gland-plate clearance in the enclosure. ## Lifecycle and compliance — active production, made to order Listed as active and in the mature lifecycle stage. The product class is C — manufactured or produced to order, so it is not a stocked shelf item; each unit is built against a customer order, which means lead time depends on the production queue at the time of the RFQ.","metaTitle":"Siemens 6SL3210-1PC31-6UL0 SINAMICS G120 PM240-2, 37 kW HO","metaDescription":"Siemens 6SL3210-1PC31-6UL0 SINAMICS G120 Power Module PM240-2, unfiltered, 37 kW high overload at 200-240 V, IP20. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3210-1PC31-6UL0","Group Code":"R220","description":"SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 45kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708 X 305 X 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8","Product Group":"9775","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"Air-cooled Power Modules in blocksize format","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : 9N9999","Packaging dimensions (L x W x H)":"745.00 x 469.00 x 385.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 01-01-17","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,291.84","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjEwLTFQQzMxLTZVTDAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': 'ae15f72eaa3a8e05642ffc8561c87909.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/ae15f72eaa3a8e05642ffc8561c87909.pdf', 'status': 1}","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=313346&mlfb=6SL3210-1PC31-6UL0"},"ai":{"faq":[{"question":"What is the difference between high-overload and low-overload ratings on this drive?","answer":"High-overload (HO) provides 37 kW continuous with 200 % peak for 3 seconds at 50 °C ambient. Low-overload (LO) provides 45 kW continuous with 150 % peak for 3 seconds at 40 °C ambient. The HO rating is for applications needing short torque spikes; LO suits constant-torque loads where peak demand is modest."},{"question":"Does 6SL3210-1PC31-6UL0 include a control unit?","answer":"No, it ships without a control unit or operator panel. It requires a separate SINAMICS G120 CU (e.g., CU240E-2 or CU250S-2) and is approved for firmware V4.7 HF8 and later."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3210-1PC31-6UL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3210-1PC31-6UL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}