{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3210-1PH26-2UL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3210-1PH26-2UL0","canonicalUrl":"https://aoctrl.com/siemens/6SL3210-1PH26-2UL0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3210-1PH26-2UL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120 Power Module PM240-2, air-cooled blocksize format, 6SL3210-1PH26-2UL0, 45 kW high overload / 55 kW low overload, 3AC 500-690 V, IP20, without filter.","salesMarkdown":"## Active production — lifecycle and sourcing posture The 6SL3210-1PH26-2UL0: This SINAMICS G120 Power Module is listed as active in production. The lifecycle stage is marked mature, meaning the design is stable and the part has been in volume production long enough that the firmware version (V4.7 HF8) and hardware revision are well-characterized under change control. Product class D indicates this is made to order against customer specifications, requiring engineering services — not a stocked shelf item. ## Overload profile and application fit High overload rating: 45 kW continuous with 200 % for 3 s, 150 % for 57 s, and 100 % for 240 s, ambient -20 to +50 °C. Low overload rating: 55 kW continuous with 150 % for 3 s, 110 % for 57 s, 100 % for 240 s, ambient -20 to +40 °C. The HO profile suits cyclic loads like conveyors or presses where peak torque is needed briefly; the LO profile fits pumps or fans running steady-state near the motor nameplate. Input is 3-phase AC 500-690 V +10/-20 %, 47-63 Hz. The wide voltage band covers 525 V and 690 V grids common in European and North American industrial plants without a step-down transformer. No built-in line filter — plan external EMC filtering if the installation must meet EN 61800-3 Category C2 or C3 conducted emission limits. ## Compliance and documentation for validation RoHS compliant since 01-01-17. REACH Article 33 notification applies: lead (CAS 7439-92-1) above 0.1 % w/w in the product. The REACH candidate list declaration is available from Siemens — include it in the material declaration package for GMP or environmental compliance audits.","metaTitle":"Siemens 6SL3210-1PH26-2UL0 SINAMICS G120 PM240-2, 45 kW HO","metaDescription":"Siemens 6SL3210-1PH26-2UL0 SINAMICS G120 Power Module PM240-2, 45 kW high overload, 55 kW low overload, 3AC 500-690 V, IP20, active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3210-1PH26-2UL0","Group Code":"R220","description":"SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC500-690V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 55kW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 551 X 275 X 237 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 HF8","Product Group":"9775","Product class":"D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)","Quantity Unit":"1 Piece","Product Family":"Air-cooled Power Modules in blocksize format","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : 9N9999","Packaging dimensions (L x W x H)":"595.00 x 400.00 x 350.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 01-01-17","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,962.40","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjEwLTFQSDI2LTJVTDAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': '7bd1a146fadcf9ee0f844f26974f7675.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/7bd1a146fadcf9ee0f844f26974f7675.pdf', 'status': 1}","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=506199&mlfb=6SL3210-1PH26-2UL0"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for this drive?","answer":"RoHS compliance since 01-01-17 is confirmed. REACH Article 33 declares lead above 0.1 % w/w. The product carries an AL N / ECCN 9N9999 export classification. Full EU Declaration of Conformity and REACH candidate list statement are available from Siemens documentation portal."},{"question":"What is the difference between the high overload and low overload ratings?","answer":"High overload (HO) is 45 kW continuous with 200 % for 3 s, 150 % for 57 s, 100 % for 240 s, ambient -20 to +50 °C. Low overload (LO) is 55 kW continuous with 150 % for 3 s, 110 % for 57 s, 100 % for 240 s, ambient -20 to +40 °C. HO handles peak torque cycles; LO handles steady loads at higher continuous power."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3210-1PH26-2UL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3210-1PH26-2UL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}