{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3210-1RE28-8AL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3210-1RE28-8AL0","canonicalUrl":"https://aoctrl.com/siemens/6SL3210-1RE28-8AL0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3210-1RE28-8AL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120 PM240P-2 Power Module, 6SL3210-1RE28-8AL0, 37 kW high overload / 45 kW low overload, 380-480 V 3-phase, 47-63 Hz, IP20, with integrated Class A filter.","salesMarkdown":"## Duty profile that decides the application The 6SL3210-1RE28-8AL0: This PM240P-2 Power Module delivers 37 kW at 150 % overload for 60 s, then settles to 100 % for 240 s under high-overload duty — that's the cycle for a punch press or extruder that needs a burst of torque without tripping the drive. Switch to low-overload mode and it handles 45 kW continuous with a 135 % peak for 3 s, then 110 % for 57 s — a conveyor or pump that rarely sees transient loads can run at the higher base rating. The integrated Class A filter means it meets EN 61800-3 conducted emission limits without an external filter box — saves a DIN rail slot and a wiring step in the panel. ## Lifecycle reality — NRND and what that means for the BOM Siemens lists this module as NRND (Not Recommended for New Design) — the drive family is still supported for existing installations, but new projects should look at the current G120X or G120XA series for long-term availability. Product class C means it's manufactured to order and cannot be returned or re-stocked — confirm the BOM line before committing, because once ordered it's yours. RoHS compliant since December 2016, but the REACH declaration flags lead (CAS 7439-92-1) above 0.1 % — factor that into any substance-restriction audit for the end customer. ## Physical fit and integration constraints The module measures 551 x 275 x 237 mm (HxWxD) and ships in a 595 x 400 x 350 mm box — plan the panel cut-out and the incoming goods staging area accordingly. IP20 degree of protection means it's intended for a clean, dry cabinet — no washdown or dust exposure without a separate enclosure. Released for use with Control Unit firmware V4.7 SP6 HF1 or later — if the site is running older firmware, the module may not parameterise correctly on first power-up.","metaTitle":"Siemens 6SL3210-1RE28-8AL0 SINAMICS G120 PM240P-2, 37 kW HO","metaDescription":"Siemens 6SL3210-1RE28-8AL0 SINAMICS G120 Power Module PM240P-2, 37 kW high overload, 45 kW low overload, 380-480 V, NRND.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3210-1RE28-8AL0","Group Code":"R220","description":"SINAMICS G120 Power Module PM240P-2 with integrated Class A filter 380-480V3AC+10/-20% 47-63Hz Power high overload: 37 kW at 150% 60 s, 100% 240 s; Ambient temperature -20 to +50 °C(HO); Power Low overload: 45 kW at 135% 3 s, 110% 57 s, 100% 240 s; Ambient temperature -20 to +40 °C (LO) 551x 275x 237 (HxWxD), FSE Degree of protection IP20 without Control Unit and operating unit Released as of CU firmware Version V4.7 SP6 HF1","Product Group":"5678","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"PM240P-2 Power Modules","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : 9N9999","Packaging dimensions (L x W x H)":"595.00 x 400.00 x 350.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 22-12-16","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,271.52","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjEwLTFSRTI4LThBTDAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': '983e54f6803b39e63cbbf15ef178da75.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/983e54f6803b39e63cbbf15ef178da75.pdf', 'status': 1}","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=809464&mlfb=6SL3210-1RE28-8AL0"},"ai":{"faq":[{"question":"Where can I buy 6SL3210-1RE28-8AL0 and get a price?","answer":"This module is sourced to order through independent distribution."},{"question":"What compliance documentation does Siemens provide for 6SL3210-1RE28-8AL0?","answer":"RoHS compliance is confirmed since 22 December 2016. The REACH Article 33 declaration notes lead (CAS 7439-92-1) above 0.1 % by weight. Export control is AL N / ECCN 9N9999."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3210-1RE28-8AL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3210-1RE28-8AL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-20T22:00:09.116Z","lastPublished":"2026-07-20T22:00:09.116Z","indexable":true}}