{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3220-3YE36-0UB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3220-3YE36-0UB0","canonicalUrl":"https://aoctrl.com/siemens/6SL3220-3YE36-0UB0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3220-3YE36-0UB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120X variable frequency drive, 6SL3220-3YE36-0UB0, 37 kW, 380-480 VAC 3-phase, IP20, FSD frame, with Intelligent Operator Panel, MODBUS RTU/BACnet MS/TP/USS.","salesMarkdown":"## 37 kW pump and fan drive with built-in fieldbus The 6SL3220-3YE36-0UB0 is a SINAMICS G120X variable frequency drive rated at 37 kW with 110% overload capability for 60 seconds and 100% for 240 seconds — a duty cycle matched to centrifugal pump and fan loads where the peak torque demand is brief. Input range is 380-480 VAC three-phase, +10/-20%, 47-63 Hz, unfiltered — plan for external line reactor if the supply has harmonic limits or the installation requires a clean sine wave at the drive input. The FSD frame size and IP20 / UL open type enclosure mean it mounts inside a panel, not standalone. Packaging dimensions are 305 x 545 x 430 mm — verify the enclosure depth before cutting the backplate. ## Fieldbus and operator interface — no extra modules needed MODBUS RTU, BACnet MS/TP, and USS are integrated on the drive — no fieldbus module to order, slot, or configure separately. For a building-services or water/wastewater installation, the BACnet MS/TP connection talks directly to the BMS without a gateway. The Intelligent Operator Panel (IOP) is included — local start/stop, parameter editing, and diagnostics without a laptop. Commissioning engineers can set the motor data and ramp times at the drive face. No IO expansion is fitted — the base I/O covers a run command, analog reference, and a fault relay. If the application needs extra digital inputs or a second analog output, add an external IO block on the fieldbus. ## Active production and compliance paperwork RoHS compliant since 01 July 2006, and REACH Article 33 disclosure is available on the current candidate list — the compliance documentation covers EU substance restrictions for equipment shipped into regulated markets. Export control is AL: N / ECCN: N — no special license required for most destinations, but confirm the end-use country if it falls under a regional embargo. The 37 kW rating at 110% overload for 60 seconds matches the NEMA MG1 variable-torque starting profile — a pump starting against a closed discharge valve draws less than 110% FLA, so the drive stays in the continuous duty band. Ambient temperature range is -20 to +45 °C — inside a non-conditioned enclosure in a plant that hits 40 °C, the drive has 5 °C of headroom before derating. Above 45 °C, the output current must be reduced per the derating curve in the manual. The unfiltered input means the drive generates conducted emissions at the switching frequency.","metaTitle":"Siemens 6SL3220-3YE36-0UB0 SINAMICS G120X, 37 kW","metaDescription":"SINAMICS G120X variable frequency drive, 37 kW at 110% overload, 380-480 VAC, IP20, FSD frame. Active production, MODBUS RTU/BACnet MS/TP integrated.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Group Code":"R220","Product Group":"4R52","Product class":"B: return restricted, please contact your Siemens partner/contact","Quantity Unit":"1 Piece","Product Family":"Ordering Data Overview","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : N","Packaging dimensions (L x W x H)":"305.00 x 545.00 x 430.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 01-07-06","REACH Art. 33 Duty to inform according to the current list of candidates":"Reach Information"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6SL3220-3YE36-0UB0?tree=CatalogTree","alternativesUrl":"https://aoctrl.com/api/mcp/products/6SL3220-3YE36-0UB0/alternatives.json"},"ai":{"faq":[{"question":"What fieldbus protocols are built into this drive?","answer":"MODBUS RTU, BACnet MS/TP, and USS are integrated on the drive's control board — no additional communication module is needed for these protocols."},{"question":"What compliance documentation does Siemens provide for 6SL3220-3YE36-0UB0?","answer":"RoHS compliance since 01 July 2006 and REACH Article 33 duty-to-inform documentation on the current candidate list are available. Export control is AL: N / ECCN: N."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3220-3YE36-0UB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3220-3YE36-0UB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}