{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3220-3YE60-1CB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3220-3YE60-1CB0","canonicalUrl":"https://aoctrl.com/siemens/6SL3220-3YE60-1CB0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3220-3YE60-1CB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120X infrastructure converter, 6SL3220-3YE60-1CB0, 400 kW, 3AC 380-480 V, IP20, size FSH, with intelligent operator panel and integrated MODBUS RTU / BACnet MS/TP.","salesMarkdown":"## 400 kW pump and fan drive with native building automation fieldbus The Siemens 6SL3220-3YE60-1CB0 is a SINAMICS G120X infrastructure converter rated 400 kW with a 135% overload capability for 3 seconds and 110% for 60 seconds — the overload profile matches the starting and transient demands of centrifugal pumps, fans, and compressors in HVAC and water/wastewater duty. It ships with an integrated RFI suppression filter for Category C3, meaning it meets conducted emissions limits for industrial second-environment installations (not residential). The IP20 / UL open type enclosure requires mounting inside a panel or cabinet that provides touch and dust protection. ## Fieldbus and I/O — no extra gateway for BAS integration Three fieldbus protocols are integrated on the drive: MODBUS RTU, BACnet MS/TP, and USS. For a building automation system (BAS) using BACnet, this drive connects directly to the MS/TP trunk without an external gateway or protocol converter. The Intelligent Operator Panel (IOP) provides local parameter access, diagnostics, and commissioning wizard — no laptop needed for basic setup.","metaTitle":"Siemens 6SL3220-3YE60-1CB0 SINAMICS G120X VFD, 400 kW","metaDescription":"Siemens 6SL3220-3YE60-1CB0 SINAMICS G120X VFD, 400 kW at 135% overload, 3AC 380-480V, IP20, MODBUS RTU/BACnet. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3220-3YE60-1CB0","Group Code":"R220","description":"SINAMICS G120X Rated power: 400 kW at 135% 3 s or 110% 60 s, 100% 240 s; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 °C Size: FSH Degree of protection IP20 / UL open type With Intelligent Operator Panel With IO expansion Fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS","Product Group":"4R53","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : EAR99H","Packaging dimensions (L x W x H)":"800.00 x 1,870.00 x 600.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 11-03-20","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjIwLTNZRTYwLTFDQjAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': '7d602345e25e1d3e2bd51fda2a399d2d.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/7d602345e25e1d3e2bd51fda2a399d2d.pdf', 'status': 1}","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6SL3220-3YE60-1CB0?tree=CatalogTree"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 6SL3220-3YE60-1CB0?","answer":"The drive is RoHS compliant since 11 March 2020 and carries a REACH Article 33 disclosure for lead (CAS 7439-92-1) above 0.1% by weight. Export control classification is AL: N / ECCN: EAR99H. The RFI filter meets C3 conducted emissions limits for industrial environments."},{"question":"What is the 6SL3220-3YE60-1CB0's overload capability?","answer":"The drive is rated for 135% overload for 3 seconds, 110% for 60 seconds, and 100% for 240 seconds. This overload profile is sized for pump and fan starting torque and transient load spikes without tripping the drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3220-3YE60-1CB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3220-3YE60-1CB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}