{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3220-3YE60-1CF0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3220-3YE60-1CF0","canonicalUrl":"https://aoctrl.com/siemens/6SL3220-3YE60-1CF0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3220-3YE60-1CF0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120X infrastructure converter, 6SL3220-3YE60-1CF0, 400 kW, 3AC 380-480 V, IP20, Size FSH, with integrated PROFINET PN / Ethernet IP, RFI filter C3, IOP.","salesMarkdown":"## 400 kW at 135% overload — sizing for pump and fan loads The 6SL3220-3YE60-1CF0: Rated 400 kW continuous with a 135% overload capability for 3 s, then 110% for 60 s, and 100% for 240 s — this matches the start-and-run profile of centrifugal pumps and fans where the breakaway torque is low but the inertia keeps the drive in overload during acceleration. The 3 s window at 135% is tight enough that the VFD's thermal model, not the IGBT, sets the trip point; expect nuisance trips if the load exceeds 135% for more than 3 s during a stalled-impeller event. Input voltage range is 3AC 380-480 V +10/-20% at 47-63 Hz — the -20% drop to 304 V is unusual for a 400 V class drive and means this unit can ride through a brownout that would drop a standard 400 V drive offline. The RFI suppression filter is Category C3, which meets the conducted emission limits for industrial second-environment installations but not residential (C1/C2) — plan a filter on the line side if the drive sits in a building with a shared utility transformer. ## PROFINET PN and Ethernet IP — one cable, no gateway Fieldbus is integrated PROFINET PN and Ethernet IP on the same port — no external communication module needed, no gateway to map between the two protocols. The drive auto-negotiates the protocol on power-up based on the master's frame; the I/O data map (process data words, status words, control words) follows the PROFIdrive profile for PROFINET and the ODVA AC/DC profile for Ethernet IP. Commissioning engineers should verify the controller's cycle time matches the drive's minimum bus cycle (typically 1-4 ms on this class) — a mismatch causes a watchdog timeout on the fieldbus interface before the drive faults. The Intelligent Operator Panel (IOP) is included — that's the handheld display with a 4-line LCD, soft keys, and a USB port for parameter upload/download. It stores up to 10 parameter sets; for fleet commissioning, clone the first drive's setup and load it into the next unit without a laptop. The IOP also shows fault history with time stamps and a plain-text message (not just a code) — useful for diagnosing a line-down event on the shop floor. ## Size FSH frame — panel fit and mounting constraints The drive ships in Size FSH — the largest frame in the G120X lineup, with packaging dimensions 800 x 1,870 x 600 mm. That's roughly 31.5 x 73.6 x 23.6 inches; plan the enclosure depth to allow rear clearance for the heatsink and the DC bus bar connections. ## Compliance documentation for cross-border trade RoHS compliant since 11 March 2020; REACH Article 33 declaration lists Lead (CAS 7439-92-1) above 0.1% w/w in the product — this means a downstream user notification is required under EU REACH if the drive is incorporated into a finished product sold into Europe. Export control is AL: N / ECCN: EAR99H — no special license needed for most destinations, but EAR99H carries a dual-use notation for high-performance drives; check the destination country's sanctions list before shipping.","metaTitle":"Siemens 6SL3220-3YE60-1CF0 SINAMICS G120X VFD, 400 kW, IP20","metaDescription":"SINAMICS G120X VFD, 400 kW at 135% overload 3 s, 3AC 380-480 V, PROFINET PN/Ethernet IP, IP20, active production. Quoted to order against BOM. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3220-3YE60-1CF0","Group Code":"R220","description":"SINAMICS G120X Rated power: 400 kW at 135% 3 s or 110% 60 s, 100% 240 s; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 °C Size: FSH Degree of protection IP20 / UL open type With Intelligent Operator Panel With IO expansion Fieldbus integrated: PROFINET PN, Ethernet IP","Product Group":"4R53","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"SINAMICS G120X infrastructure converters for HVAC/Water/Wastewater","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : EAR99H","Packaging dimensions (L x W x H)":"800.00 x 1,870.00 x 600.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 11-03-20","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjIwLTNZRTYwLTFDRjAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': 'cec0ea317ac7d056eef803dc4d02d181.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/cec0ea317ac7d056eef803dc4d02d181.pdf', 'status': 1}","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6SL3220-3YE60-1CF0?tree=CatalogTree"},"ai":{"faq":[{"question":"What is the group code and product group for 6SL3220-3YE60-1CF0?","answer":"The group code is R220 and the product group is 4R53. These are Siemens internal classification codes used for spare-parts cross-referencing and catalog filtering — the R220 group covers SINAMICS G120X drives in the FSH frame size."},{"question":"What compliance documentation does Siemens provide for this drive?","answer":"RoHS compliance since 11 March 2020; REACH Article 33 declaration confirming Lead (CAS 7439-92-1) above 0.1% w/w; export control classification AL: N / ECCN: EAR99H. The drive also carries the CE mark for the EU market and UL recognition under the UL open type designation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3220-3YE60-1CF0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3220-3YE60-1CF0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}