{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3220-3YH28-0AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3220-3YH28-0AP0","canonicalUrl":"https://aoctrl.com/siemens/6SL3220-3YH28-0AP0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3220-3YH28-0AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120X, 6SL3220-3YH28-0AP0, 15 kW VFD, 500-690 V 3AC, IP20, frame size FSD, with integrated C2 EMC filter and PROFIBUS DP.","salesMarkdown":"## 15 kW at 500–690 V — frame FSD with integrated C2 filter The 6SL3220-3YH28-0AP0: This SINAMICS G120X variable frequency drive is rated for 15 kW continuous output at 110 % overload for 60 seconds, or 100 % for 240 seconds, on a 500–690 V three-phase supply (+10/-20 %), 47–63 Hz. The frame size is FSD, with degree of protection IP20 / UL open type and painting class 3C2. It ships with an integrated radio interference suppression filter for category C2, plus an Intelligent Operator Panel (IOP). No IO expansion module is included; fieldbus is onboard PROFIBUS DP. ## Active lifecycle — no LTB or obsolescence notice RoHS compliance dates from 01 July 2006; REACH candidate-list information is available on request. ## Packaging and compliance documentation Packaged as a single piece in a carton measuring 305 x 545 x 430 mm. Export control is AL N / ECCN N. The product class is B (return restricted — contact your Siemens partner for returns).","metaTitle":"Siemens 6SL3220-3YH28-0AP0 SINAMICS G120X VFD, 15 kW","metaDescription":"Siemens 6SL3220-3YH28-0AP0 SINAMICS G120X drive, 15 kW at 110% overload, 500-690 V 3AC, IP20, PROFIBUS DP, C2 filter. Active production — quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"6SL3220-3YH28-0AP0","Group Code":"R220","description":"SINAMICS G120X rated power: 15 kW at 110% 60s, 100% 240s radio interference suppression filter for category C2 500-690V3AC+10/-20% 47-63Hz ambient temperature -20 to +45 °C frame size: FSD degree of protection IP20 / UL open type painting 3C2 with Intelligent Operator Panel without IO expansion fieldbus integrated: PROFIBUS DP","Product Group":"4R52","Product class":"B: return restricted, please contact your Siemens partner/contact","Quantity Unit":"1 Piece","Product Family":"Ordering Data Overview","lifecycle_stage":"mature","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : N","Packaging dimensions (L x W x H)":"305.00 x 545.00 x 430.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 01-07-06","REACH Art. 33 Duty to inform according to the current list of candidates":"Reach Information"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0wzMjIwLTNZSDI4LTBBUDAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': '0faefdc0c43985104a68259da527ac90.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/0faefdc0c43985104a68259da527ac90.pdf', 'status': 1}","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6SL3220-3YH28-0AP0?tree=CatalogTree"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3220-3YH28-0AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3220-3YH28-0AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}