{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL3224-0BE24-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL3224-0BE24-0AA0","canonicalUrl":"https://aoctrl.com/siemens/6SL3224-0BE24-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL3224-0BE24-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120 PM240 power module, frame FSB, 4 kW high overload, 10.2 A, 3AC 380-480 V, integrated Class A filter and braking chopper, IP20.","salesMarkdown":"## What this power module drives on the line The Siemens 6SL3224-0BE24-0AA0 is the PM240 power stage out of the SINAMICS G120 line, frame-size FSB, listed as a spare part — the Control Unit and Basic Operator Panel are not included and have to be ordered separately when a complete drive is built up. It is sized for a 4 kW three-phase motor on a 380-480 V supply: 3AC 380/480 V input, 3AC 0-380/480 V output, 10.2 A rated current, 50/60 Hz mains. That is the standard pairing for a 4 kW induction machine — pump, conveyor, fan, mixer — on a 400 V or 480 V industrial bus. ## Reading the 4 kW rating — high-overload duty, not continuous The 4 kW figure carries a high-overload envelope: 200 % for 3 s, 150 % for 57 s, 100 % for 240 s, repeating in a cold-start cycle. That is the duty profile for cyclic loads — conveyors, mixers, positive-displacement pumps — where short inrush or jam-clearance torque pushes the current well above nominal for a few seconds. For a steady fan or centrifugal pump that lives at nameplate, the same frame is over-spec and a smaller PM240 in the family would be the cheaper fit. An ambient window of -10 to +50 °C is published, which is the cabinet-internal envelope once the module is mounted behind a closed door. Derating above 40 °C follows the standard SINAMICS curve in the manual — buyers running a hot panel should not assume full 4 kW at 50 °C without checking the curve. ## Integrated filter, braking chopper, what that means at the panel Class A line filter is integrated on the module, so no external footprint is needed to meet conducted-emission Class A on the mains side. For Class B (residential or light-industrial) emissions an additional footprint filter is still required downstream — the integrated filter does not cover Class B on its own. The braking chopper is integrated as well, which means the only external hardware needed for a decelerating load is the brake resistor itself, wired to the dedicated terminals on the module. No external chopper unit, no extra DIN space. ## Mature product, quoted-to-order posture A buyer specifying this code is typically filling an existing BOM line, replacing a failed unit on an installed machine, or matching an established spare-parts list — not starting a green-field design. The spare-part designation matters for the RFQ: this is the bare power module only, so the Control Unit and any operator panel need to be specified as separate line items if the application is a complete drive. Cross-referencing the SINAMICS G120 configuration in the Siemens DT Configurator with the existing Control Unit order code is the right next step before placing the order.","metaTitle":"Siemens 6SL3224-0BE24-0AA0 SINAMICS PM240, 4 kW, 480 V","metaDescription":"Siemens 6SL3224-0BE24-0AA0 SINAMICS G120 PM240 power module, 4 kW high overload, 10.2 A, 3AC 380-480 V, with integrated Class A filter and braking chopper.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Type":"WITH FILTER FREQUENCY INVERTER","Model":"6SL3 224-0BE24-0AA0","Power":"4 kw","title":"6SL3224-0BE24-0AA0","Family":"SINAMICS POWER MODULE 240","Weight":"4.3 Kg","Condition":"New","Frequency":"50/60 Hz","description":"***spare part*** SINAMICS G120 PM240 Power Module with integrated filter class A with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz power high overload: 4.0 kW at 200% 3 s,150% 57 s,100% 240 s ambient temperature -10 to +50 °C 270 x 153 x 165 (HxWxD), FSB degree of protection IP20 without Control Unit and BOP","Rated Current":"10.2 A","Input: Voltage":"3AC 380 / 480 V","Output: Voltage":"3AC 0-380 / 480 V","lifecycle_stage":"mature","Protection Class":"IP20"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,484.76","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/971d0a06acdb8071cdd5f13808186be2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=117795&mlfb=6SL3224-0BE24-0AA0"},"ai":{"faq":[{"question":"What does the 6SL3224-0BE24-0AA0 drive at 480 V?","answer":"At 380-480 V three-phase input, the module delivers 3AC 0-380/480 V output at 10.2 A, rated 4 kW under the high-overload cycle (200 % 3 s / 150 % 57 s / 100 % 240 s). That maps to a 4 kW induction motor — pump, conveyor, fan, mixer — sized for cyclic rather than steady continuous load."},{"question":"How can I order the 6SL3224-0BE24-0AA0 and what is the lead time?","answer":"No stock count, ships-today claim, or lead-time figure is asserted on this page; the Control Unit and any operator panel are separate line items because the spare-part designation ships the bare power stage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL3224-0BE24-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL3224-0BE24-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}