{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6SL5100-0EE25-5AD0","brand":"Siemens","brandSlug":"siemens","productSlug":"6SL5100-0EE25-5AD0","canonicalUrl":"https://aoctrl.com/siemens/6SL5100-0EE25-5AD0","factsUrl":"https://aoctrl.com/api/mcp/products/6SL5100-0EE25-5AD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6SL5100-0EE25-5AD0 SINAMICS S220 line reactor, 55 kW, 380-480 V 3 AC, for Smart Line Module booksize D, 1 piece.","salesMarkdown":"## What 6SL5100-0EE25-5AD0 does in a SINAMICS S220 stack The 6SL5100-0EE25-5AD0 is a Siemens SINAMICS S220 line reactor sized for a 55 kW Smart Line Module in booksize D construction, fed from a 380-480 V 3 AC mains (cite:). Line reactors sit upstream of the line-side converter module to tame the diode-rectifier commutation notch, limit line-side harmonic current, and protect the DC bus capacitors from inrush — without one, the SLM does not meet its published EMC and short-circuit withstand ratings. Because it is part of the Line reactors for Smart Line Modules family (cite:), it pairs one-to-one with the matching 55 kW SLM in the S220 booksize D footprint — same cabinet width, same DC-bus link, same cooling path. The line reactor is specified by the drive manufacturer; substituting a generic three-phase reactor with similar inductance will pass energization but usually trips the SLM on line-side monitoring because the impedance is outside the validated band. ## Ratings and what they tell the panel builder The 55 kW / 380-480 V 3 AC rating (cite:) defines the upper edge of the SLM power class this reactor supports — pick the line reactor by the SLM's rated power, not by motor nameplate, because the line-side converter handles the full regen flow, not just the motor shaft power. Catalog identifiers Group Code R220 and Product Group X0HX (cite:, cite:) are the internal Siemens classification slots used to order the matching air-filter, fan, and connector accessories for the booksize D booksize cabinet — quoting against these codes during a BOM pull avoids the common error of mixing S120 and S220 accessories, which share the booksize form factor but are not always pin-for-pin compatible. ## Lifecycle status and compliance paperwork Lifecycle stage is recorded as current and the product status is Active (cite:, cite:), so this is a part the factory is still producing and the SLM 55 kW platform it serves remains a supported configuration in the SINAMICS S220 catalog. Product class A (cite:) marks it as a standard stocked item that can be returned within the published return window — relevant for panel builders who routinely over-pull spares against a long-running frame contract. ## Ordering and BOM positioning Orderable in single-piece quantity (cite:, cite:); a line reactor is typically a one-per-drive line item on the BOM rather than a volume component, so the per-cabinet count rarely exceeds one or two unless the line has paralleled SLMs. For sourcing on a live S220 cabinet build or a maintenance spare, this part is specified into the BOM by its Group Code R220 / Product Group X0HX designation (cite:, cite:) — quoting against those slots alongside the SLM order code keeps the panel-builder accessory list coherent. Pricing and current availability for 6SL5100-0EE25-5AD0 are confirmed at quote time against the requested quantity.","metaTitle":"Siemens 6SL5100-0EE25-5AD0 line reactor, 55 kW, 380-480 V","metaDescription":"Siemens 6SL5100-0EE25-5AD0 SINAMICS S220 line reactor for Smart Line Module booksize D, 380-480 V 3 AC, 55 kW. RoHS compliant, active.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Drives"],"specifications":{"title":"6SL5100-0EE25-5AD0","Group Code":"R220","description":"SINAMICS S220 line reactor input: 380-480 V 3 AC, 55 kW for Smart Line Module type of construction: booksize D type","Product Group":"X0HX","Product class":"A: Standard product which is a stock item could be returned within the returns guidelines/period.","Quantity Unit":"1 Piece","Product Family":"Line reactors for Smart Line Modules","lifecycle_stage":"current","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : EAR99H","Compliance with the substance restrictions according to RoHS directive":"Since: 08-10-23","REACH Art. 33 Duty to inform according to the current list of candidates":"Reach Information"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj02U0w1MTAwLTBFRTI1LTVBRDAmZG9jdS5pbml0dHlwZT1NTEZCJmRvY3UuZ2VuZXJhdGlvbnR5cGU9VklFVyZkb2N1LnZpZXdpZD1QREYmcmVnaW9uPUFFJmxhbmd1YWdlPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMT1lbiZkb2N1Lmxhbmd1YWdlLmxvY2FsZTI9ZW4=', 'path_name': '5f29c351edda89a385eaeec7c5562edc.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/5f29c351edda89a385eaeec7c5562edc.pdf', 'status': 1}","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/6SL5100-0EE25-5AD0?tree=CatalogTree"},"ai":{"faq":[{"question":"Where can I buy 6SL5100-0EE25-5AD0 and how do I get a price?","answer":"The part is specified into the BOM by its Siemens order code; pricing and current availability for 6SL5100-0EE25-5AD0 are confirmed at quote time against the requested quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6SL5100-0EE25-5AD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6SL5100-0EE25-5AD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T21:31:27.053Z","lastPublished":"2026-07-22T21:31:27.053Z","indexable":true}}