{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"7SJ6111-5EB02-1FA0/FF,,F","brand":"Siemens","brandSlug":"siemens","productSlug":"7SJ6111-5EB02-1FA0-FF~6~6F","canonicalUrl":"https://aoctrl.com/siemens/7SJ6111-5EB02-1FA0-FF~6~6F","factsUrl":"https://aoctrl.com/api/mcp/products/7SJ6111-5EB02-1FA0%2FFF%2C%2CF","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 7SJ61 series multifunction protection relay, order code 7SJ6111-5EB02-1FA0/FF,F, panel flush mount, screw-type terminals, 110-250 VDC / 115-230 VAC auxiliary supply, 8 binary inputs, 8 binary outputs, 1 live status contact.","salesMarkdown":"## Panel flush mount, 8 BI / 8 BO, 110-250 VDC supply The 7SJ6111-5EB02-1FA0/FF,,F: The 7SJ6111-5EB02-1FA0/FF,F is a Siemens 7SJ61 multifunction protection relay in a 1/3 19-inch housing with 8 binary inputs, 8 binary outputs, and one live status contact. The unit version E specifies panel flush mounting with screw-type terminals accepting direct connection or ring-type cable lugs — a standard fit for retrofit into existing switchgear cutouts where the relay face must sit flush with the panel door. Rated auxiliary voltage spans 110 to 250 V DC and 115 to 230 V AC, with the binary input threshold set at 88 V DC. This means the relay holds the unit on the grid across the common station battery voltages (110/125/220 VDC) without an external converter, provided the DC supply stays above the 88 V threshold for reliable input sensing. Measuring inputs are configured for Iph = 1 A, Ie = 1 A with a minimum detectable current of 0.05 A — sized for direct connection to CT secondaries in medium-voltage feeder protection schemes where 1 A CTs are standard. ## Service interface and regional defaults The service interface (Port C) is an electrical RS485 port running DIGSI 4 protocol, with modem and RTD-box support. This is the commissioning engineer's download port — the RS485 physical layer matches the legacy DIGSI 4 cable, so no USB converter is needed for initial parameterisation on site. The default language is English (GB), with other languages selectable via DIGSI. This covers the common frequency and protection-curve requirements for export panels or multi-standard installations. Fault recording is included as standard (position 15), meaning the relay captures oscillographic event data for post-fault analysis — essential for coordinating protection operations and verifying that the trip sequence held the unit on the grid as intended. ## Current production, quoted to order For volume BOM commitments, availability and pricing are confirmed at RFQ against the specific quantity and delivery window.","metaTitle":"Siemens 7SJ6111-5EB02-1FA0/FF,,F 7SJ61 Protection Relay","metaDescription":"Siemens 7SJ6111-5EB02-1FA0/FF,,F 7SJ61 multifunction protection relay, panel flush mount, screw terminals, 110-250 VDC/115-230 VAC supply, 8 BI/8 BO, active","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Product Type":"7SJ61 Multifunction Protection Relay","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bde5de3660454ec4242a97308a5a443e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/7SJ6111-5EB02-1FA0%2FFF%2C%2CF/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/7SJ6111-5EB02-1FA0-FF~6~6F","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/7SJ6111-5EB02-1FA0-FF~6~6F when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}