{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"7SJ8011-5EB16-3FA0","brand":"Siemens","brandSlug":"siemens","productSlug":"7SJ8011-5EB16-3FA0","canonicalUrl":"https://aoctrl.com/siemens/7SJ8011-5EB16-3FA0","factsUrl":"https://aoctrl.com/api/mcp/products/7SJ8011-5EB16-3FA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPROTEC Compact 7SJ80 overcurrent protection relay, flush-mount housing with screw terminals, 60-220 VDC / 115-230 VAC auxiliary supply, Ethernet front port, 4 current inputs (1A/5A).","salesMarkdown":"## What you're getting The 7SJ8011-5EB16-3FA0: SIPROTEC Compact 7SJ80 overcurrent time protection relay. Flush-mount housing, screw-type terminals. Powers from 60 VDC / 110 VDC / 125 VDC / 220 VDC, or 115 VAC / 230 VAC — covers both DC and AC floors in one unit. Front Ethernet port (DIGSI, not IEC 61850) and rear RS232 for DIGSI 4/modem. Four current inputs, 1 A or 5 A selectable. Three binary inputs, five binary outputs (two Form C), one live status contact. ## Protection functions This unit carries a full suite of ANSI protection functions: phase overcurrent (50/51), ground overcurrent (50N/51N), sensitive ground fault (50Ns/51Ns), high-impedance REF (87N), overload (49), trip circuit supervision (74TC), breaker failure (50BF), negative-sequence (46), undercurrent (37), lockout (86), flexible protection with current parameters, and inrush restraint. If your spec calls for auto-reclose or fault locator, this variant does not include them — skip this order code if that's a requirement.","metaTitle":"Siemens 7SJ8011-5EB16-3FA0 SIPROTEC Overcurrent Relay","metaDescription":"Siemens SIPROTEC Compact 7SJ8011-5EB16-3FA0 overcurrent protection relay, current production, Ethernet front port, DC/AC auxiliary voltage. Quoted to order – no stock held.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["General Purpose Relays"],"specifications":{"FA":"Designation = Basic version ANSI No = 50/51, 50N/51N, 50N(s)/51N(s), 87N, 49, 74TC, 50BF, 46, 37, 86 Description = Time-overcurrent protection phase I>, I>>, I>>>, Ip, Time-overcurrent protection ground IE>,IE>>,IE>>>, IEp, Sensitive ground fault protection IEE>,IEE>>,IEEp, High impedance REF, Overload protection, Trip circuit supervision, Circuit-breaker failure protection, Negative-sequence protection, Undercurrent monitoring, Lockout, Parameter changeover, Monitoring functions, Control of circuit-breaker, Flexible protection functions (current parameters), Inrush restraint","7SJ80":"7SJ80 overcurrent protection device","title":"7SJ8011-5EB16-3FA0","Weight":"4 Kg","Product No.":"7SJ8011-5EB16-3FA0","description":"SIPROTEC Compact 7SJ80 Overcurrent Time Protection","Product Type":"SIPROTEC Compact 7SJ80 Overcurrent Time Protection","Unit version":"E = Flush-mounting housing, screw-type terminal","Shipping weight":"5 Kg","lifecycle_stage":"current","Estimated Lead Time":"12 - 14 weeks.","Rated auxiliary voltage":"5 = 60 V / 110 V / 125 V / 220 V DC, 115 V, 230 V AC","Measuring/fault recording":"3 = With fault recording, average values, min/max values","Auto-reclosure, fault locator":"0 = Without","Housing, binary inputs and outputs":"1 = Housing 1/6 19’’, 4 x I, 3 BI, 5 BO (2 changeover/Form C), 1 live status contact","Measuring inputs, default settings":"1 = Iph = 1 A / 5 A, Ie =1A/5A","Port B (at bottom of device, rear)":"1 = IEC 60870-5-103 or DIGSI 4/modem, electrical RS232","Port A (at bottom of device, in front)":"6 = With Ethernet interface (DIGSI, not IEC 61850), RJ45 connector","Region-specific default and language settings":"B = Region World, IEC/ANSI, language English (language selectable), standard front"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e8598aedd585b44a554de1b364d2610d.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What auxiliary voltages does it support?","answer":"Rated for 60 VDC, 110 VDC, 125 VDC, 220 VDC, 115 VAC, or 230 VAC — six ranges in one unit."},{"question":"What protection functions are included?","answer":"Includes phase overcurrent, ground overcurrent, sensitive ground fault, high-impedance REF, overload, trip circuit supervision, breaker failure, negative-sequence, undercurrent, lockout, and flexible protection with inrush restraint. No auto-reclose or fault locator."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/7SJ8011-5EB16-3FA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/7SJ8011-5EB16-3FA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}